background image

 

 

PN 4311999 

March 2013 

© 2013 Fluke Corporation. All rights reserved. 

Specifications are subject to change without notice. 

All product names are trademarks of their respective companies. 

59 MAX/59 MAX + 

Infrared Thermometer 

Users Manual

 
 
 
 
 
 
 

Summary of Contents for 59 MAX

Page 1: ...rch 2013 2013 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 59 MAX 59 MAX Infrared Thermometer Users Manual ...

Page 2: ...ce center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states or cou...

Page 3: ... Page Introduction 1 How to Contact Fluke 1 Safety Information 2 Maintenance 5 How to Change the Battery 5 How to Clean the Product 5 Specifications 6 Standards and Agency Approval 8 Nominal Surface Emissivity 9 The Product 10 ...

Page 4: ...59 MAX 59 MAX Users Manual ii ...

Page 5: ... Warning Read all safety information before you use the Product How to Contact Fluke To contact Fluke call one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 03 6714 3114 Singapore 65 6799 5566 Anywhere in the world 1 425 446 5500 ...

Page 6: ...s and procedures that can cause damage to the Product or the equipment under test Table 1 tells you about symbols used on the Product and in this manual Warning To prevent possible electrical shock fire or personal injury Read all safety Information before you use the Product Do not use the Product if it operates incorrectly Use the Product only as specified or the protection supplied by the Produ...

Page 7: ...copes microscopes Optical tools can focus the laser and be dangerous to the eye Do not look into the laser Do not point laser directly at persons or animals or indirectly off reflective surfaces Replace the batteries when the low battery indicator shows to prevent incorrect measurements Do not use the Product around explosive gas vapor or in damp or wet environments Use the Product only as specifi...

Page 8: ...rds This product complies with the WEEE Directive 2002 96 EC marking requirements The affixed label indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product ...

Page 9: ...leave the thermometer on or near objects of high temperature How to Change the Battery To install or change the AA IEC LR06 battery open the battery compartment and replace the battery as shown in Figure 16 How to Clean the Product Use soap and water on a damp sponge or soft cloth to clean the Product case Carefully wipe the surface with a moist cotton swab The swab may be moistened with water See...

Page 10: ...0 of reading whichever is greater 32 F 4 0 F or 2 0 of reading whichever is greater 10 C to 0 C 2 0 C 14 F to 32 F 4 0 F 10 C 3 0 C 14 F 6 0 F 0 C 1 5 C or 1 5 of reading whichever is greater 32 F 3 0 F or 1 5 of reading whichever is greater 10 C to 0 C 2 0 C 14 F to 32 F 4 0 F 10 C 3 C 14 F 6 0 F Response Time 95 500 ms 95 of reading 500 ms 95 of reading Spectral Response 8 μm to 14 μm Emissivity...

Page 11: ...ever is greater Power 1 AA IEC LR06 Battery Battery Life 12 hours with laser and backlight on Weight 220 g 7 76 oz Size 156 x 80 x 50 mm 6 14 x 3 15 x 2 inches Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F without battery Operating Humidity 10 to 90 RH non condensing 30 C 86 F Operating Altitude 2000 meters above mean sea level Storage Altitude 12 00...

Page 12: ...ency Approval Ingress Protection Rating IP40 per IEC 60529 Vibration and Shock IEC 68 2 6 2 5 g 10 to 200 Hz IEC 68 2 27 50 g 11 ms Compliance EN IEC 61010 1 Laser Safety FDA and EN 60825 1 Class II Electromagnetic Compatibility 61326 1 EN 61326 2 ...

Page 13: ...ron 0 70 Asbestos 0 95 Lead 0 50 Asphalt 0 95 Oil 0 94 Brass 0 50 Paint 0 93 Ceramic 0 95 Plastic 0 95 Concrete 0 95 Rubber 0 95 Copper 0 60 Sand 0 90 Food Frozen 0 90 Steel 0 80 Food Hot 0 93 Water 0 93 Wood 0 94 Oxidized Opaque over 20 mils Natural Factory Setting Highlighted items may also be found in the emissivity table built into the Thermometer ...

Page 14: ...59 MAX 59 MAX Users Manual 10 The Product 1 2 hdi01 eps ...

Page 15: ...Infrared Thermometer The Product 11 3 4 Max Min Avg Diff 5 5 6 hdi14 eps ...

Page 16: ...59 MAX 59 MAX Users Manual 12 7 10 min OFF hdi16 eps ...

Page 17: ...Infrared Thermometer The Product 13 9 11 125 F 8 10 0 ºC 32 ºF 22 ºC 72 ºF 12 6 3 9 30 Min hdi15 eps ...

Page 18: ...59 MAX 59 MAX Users Manual 14 12 13 40 mm 300 mm 75 mm 600 mm 120 mm 900 mm 1 6 12 3 24 4 7 36 D S 59 MAX D S 8 1 38 mm 300 mm 60 mm 600 mm 100 mm 900 mm 1 5 12 2 4 24 4 36 D S 59 MAX D S 10 1 hdi08 eps ...

Page 19: ...Infrared Thermometer The Product 15 14 70 21 hdi03 eps ...

Page 20: ...59 MAX 59 MAX Users Manual 16 15 75 75 225 hdi04 eps ...

Page 21: ...Infrared Thermometer The Product 17 16 17 hdi13 eps ...

Page 22: ...59 MAX 59 MAX Users Manual 18 ...

Reviews: