Ensuring you don’t waste energy on heating the outside
world, the heater is equipped with optional open /
closed window detection. The heater recognises sudden
drops in temperature when a window or a door is
opened and turns the heating off to save energy. When
the window is closed, the heater will automatically
detect a temperature rise, and switch itself back on.
Once enabled in the setup menu, the open window
detection is fully automatic and does not require any
human intervention to be activated.
Setting-up Open Window Detection
The system has been factory set to default time and
temperature values. If necessary, all values can be
adjusted. When the heating is on, open window
detection sensor will automatically switch the heater off
when it detects a fall in temperature of 2
°
C in less than
10 minutes (this temperature can be changed in menu 7
and time in menu 6). If a temperature rise of 2
°
C in less
than 30 seconds is detected, the heater will switch itself
back on (this temperature can be changed in menu 9
and time in menu 8).
1.
Press and hold TEMP and MODE together for 5
seconds.
2.
The display will enter the setup menu.
3.
Use TEMP and MODE to change a value.
4.
Use TIME to scroll between the settings.
01 - temperature calibration
The temperature reading has been factory calibrated
but if for any reason it needs adjusting (better accuracy
required, to suit different position in the room etc.), the
reading can be recalibrated in 0.5 degrees steps.
02 - change between degrees Celsius or Fahrenheit
03 - set minimum temperature
(3.5 deg = frost protection)
When this is set, the heater will operate in any mode
should the room temperature fall below the set
temperature.
04 - set maximum temperature
When this is set, the maximum temperature in any mode
cannot exceed the limit.
05 - open window detection 0 = off, 1 = on
06 - 600 - open window detection time 600 seconds
07 - 2 - temperature drop of 2
°
C in the detection time
08 - 30 - closed window detection time of 30 seconds
09 - 2 -
temperature rise of 2
°
C in the detection time
To wall mount, the wall bracket supplied must be used.
Please refer to illustrations in Fig.1.
Remove wall bracket from the heater. Fix wall bracket to
wall using screw holes provided. Present heater to
bracket. Locate heater onto bottom lugs via 2 sets of
relevant slots in rear panel. Hinge heater upwards and
locate the top tabs into the slots in the back of the
heater and ‘click’ into position.
To remove the heater from the wall first disconnect the
power then press down on the two top tabs to release
the heater. Hinge the heater forward on the bottom
lugs. The heater can be now lifted off the bottom lugs to
remove it from the wall. The heater must not be located
immediately below a fixed socket outlet.