background image

06:00

 

10

 

20

 

08:00

 

19ºC 

4ºC 

ºC 

12:00

 

22ºC 

14:00

 

16:00

 

16ºC 

22ºC 

10ºC 

22:00

 

PROGRAM

 3

 

PROGRAM

 4

 

PROGRAM 5

 

PROGRAM 6

 

An example of one day programme on

 

HSPSSE

 

 

PROGRAM 1

 

PROGRAM 2

 

TIM

E S
ETT

IN

G

 

PROGR

A

M

M

E SET
TIN

G

 

- SET  MINUTES

- SET  DAY

- SET  HOURS

- SELECT DAY  TO  SET

- SET  MINUTES  FOR  PROGRAM

- SELECT  PROGRAM  TO  SET

- SET  TEMPERATURE  FOR  PROGRAM

Logic diagram for setting programme on

 HSPSSE 

PROG 

MODE 

TEMP 

1.

Press and hold PROG for 5 seconds to enter the
time setting.

2.

The day will be flashing.

3.

Use TEMP and MODE to navigate day, press
PROG to select day.

4.

PROG 1 will be flashing. Use TEMP and MODE to
navigate programme, use PROG to select
programme.

5.

The minutes will be flashing.

6.

To set minutes, use TEMP and MODE to change
minutes, press PROG to set the minutes.

7.

The hour will be flashing

8.

To set hour,  use TEMP and MODE to change
hour, press PROG to set the hour.

9.

The temperature will be flashing.

10. To set temperature, use TEMP and MODE to

change temperature, press PROG to set
temperature.

To add another programme repeat steps 2-10. 

The

 HSPSSE 

has a 7-day timer with up to 6

 

programming steps available for each day. In the 
programming you can set a start time and a 
temperature for each programme. Each programme 
has to be used. 

Press PROG from PROG mode to bring forward the next 
programme. To clear advance mode, press PROG. 

Press and hold TIME and TEMP together for 5 seconds. The 

display will show        symbol.  Repeat the step to unlock.  

Every time there is a demand for heat, the display will 
show the heat icon. 

- reduced heat output when the room temperature is

close to the set temperature.

- full heat output

   Light colour  

    Heater status 

STAND-BY  No heat output 

Reduced heat output 

Full power heat output 

5

8. Set 7-day programme

9. Advance mode

11 Keys locking 

10. Heat symbol on the display

12. Status light on the heater

Содержание HSP500SSE

Страница 1: ...r repaired by any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached to the appliance Reasonable care has been taken to ensure that this guide is accurate at the time of printing In the interest of progress the Company reserve the right to vary specificat...

Страница 2: ...n the appliance should be checked by a competent electrician The heater carries a Do Not Cover label to warn the user that if the appliance is covered there is a risk of overheating Cleaning Always disconnect the heater from the mains before cleaning The heater should not require any maintenance but it is strongly advised that it is kept clean An occasional wipe over with a soft cloth is all that ...

Страница 3: ...Installation MILLIMETRES WATTS A B HSP500SSE 500 442 303 HSP750SSE 750 442 303 HSP1000SSE 1000 614 477 HSP1500SSE 1500 720 582 HSP2000SSE 2000 852 713 195mm A B Fig 1 See Note 16 for Mounting 3 ...

Страница 4: ...imply activate the display by pressing any button Press TEMP then use TEMP and MODE to change the temperature Once the temperature is set leave the display to return to the main screen and the settings will be saved In this mode the HSPSSE will follow the week s time temperature programme You can temporarily override the temperature in PROG mode by simply activating the display and using the TEMP ...

Страница 5: ...EMP and MODE to change hour press PROG to set the hour 9 The temperature will be flashing 10 To set temperature use TEMP and MODE to change temperature press PROG to set temperature To add another programme repeat steps 2 10 The HSPSSE has a 7 day timer with up to 6 programming steps available for each day In the programming you can set a start time and a temperature for each programme Each progra...

Страница 6: ...librated but if for any reason it needs adjusting better accuracy required to suit different position in the room etc the reading can be recalibrated in 0 5 degrees steps 02 change between degrees Celsius or Fahrenheit 03 set minimum temperature 3 5 deg frost protection When this is set the heater will operate in any mode should the room temperature fall below the set temperature 04 set maximum te...