background image

E-2

Convection Construction Heater

Operating Instructions and OwnerÊs Manual

GENERAL HAZARD WARNING:

 FAILURE TO COMPLY WITH THE PRECAUTIONS AND 

INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN 
RESULT IN DEATH, SERIOUS BODILY INJURY AND 
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, 
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX-
IDE POISONING, AND/OR ELECTRICAL SHOCK.

 ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW 

THE INSTRUCTIONS SHOULD USE OR SERVICE THIS 
HEATER.

 IF YOU NEED ASSISTANCE OR HEATER INFORMATION 

SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. 
CONTACT THE MANUFACTURER.

WARNING: 

 NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING: 

 FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. 

KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING 
MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE 
AWAY FROM THE HEATER AS RECOMMENDED BY THE 
INSTRUCTIONS NEVER USE THE HEATER IN SPACES 
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE 
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, 
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN-
KNOWN CHEMICALS.

THE STATE OF CALIFORNIA REQUIRES THE 
FOLLOWING WARNING:

WARNING:

 COMBUSTION BY-PRODUCTS PRODUCED WHEN US-

ING THIS PRODUCT CONTAIN CARBON MONOXIDE, 
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA 
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER 
REPRODUCTIVE HARM).

WARNING:

 YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, 

SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU 
OPERATE THIS HEATER.

TABLE OF CONTENTS

HEATER SPECIFICATIONS ..........................................................E-2

WARNINGS ..............................................................................E-2

OPERATING PRECAUTIONS ......................................................E-3

SAFETY PRECAUTIONS .............................................................E-3

ODOR FADE WARNING ............................................................E-4

CAUTION: SHELL EXTENSION INSTRUCTIONS. .........................E-5

OPERATING INSTRUCTIONS .....................................................E-6

SERVICING ...............................................................................E-6

SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED ........E-6

80CV - PARTS ...........................................................................E-7

WARRANTY .............................................................................E-8

INSTRUCTIONS FOR ORDERING PARTS  ....................................E-8

SPECIFICATIONS

MODEL NO............................... .. 80CVNG

GAS TYPE................................. .. Natural gas

BTU RATING............................. ... 60,000 Btu/hr (17.7 kW)

Type of Gas:................................ For use with Natural Gas Only

Gas Supply Pressure to regulator:

Maximum:................................. . 1/2 psig (3.4 kPa)

Minimum:................................. .. 9" W.C. (2.3 kPa)

Regulator out............................. . 4" W.C. (0.98 kPa)

Ignition:..................................... . Piezo  Ignitor

Minimum Ambient Temp. Rating................0°F (-17.8°C)

Fuel Consumption:..................... . 55.5 cu-ft/hr (1.6cu-m/hr)

Fuel Orifice Port No.:................... 6

Fuel Orifice Port Size:................. . 0.0520" (1.30mm) 

 

 

 

 

 

Содержание HS80CVNG

Страница 1: ...ce Service must be performed by a qualified service agency This is an unvented gas fired portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air mu...

Страница 2: ...NNER DUST PARTICLES OR UN KNOWN CHEMICALS THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN US ING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNO...

Страница 3: ...involved SAFETY PRECAUTIONS 1 Check the heater thoroughly for damage DO NOT operate a damaged heater 2 DO NOT modify the heater or operate a heater which has been modified from its original condition...

Страница 4: ...ur fuel gas supplier FINALLY let the fuel gas service person and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must r...

Страница 5: ...NS THE SCREW HOLES WILL LINE UP STEP 4 LOCK THE CLIP INTO PLACE WITH 3 SCREWS AS SHOWN THE HEATER MUST NOT BE OPERATED UNLESS THE OUTER SHELL IS PROPERLY EXTENDED AND FULLY LOCKED INTO PLACE CAUTION N...

Страница 6: ...valve to regulate heat output CAUTION ADJUSTING BURN RATE too low can cause soot Watch for and avoid a yellow smoky flame STOP 1 Securely close valve at the natural gas supply 2 Continue to operate he...

Страница 7: ...1 18 28124 Male Conn 1 4MPT x 1 2 SAE FLR 1 26568 Fitting Adapter 1 4 FPTx1 4 MPT 1 28018 Fitting Adapter 1 8 FPT x 1 4 MPT 1 19 26255 Regulator 1 REF ITEM Description Qty 20 21896 Valve Main Burner 8...

Страница 8: ...hom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a...

Страница 9: ...es dommages mat riels ou des bles sures graves voire mortelles Cet appareil de chauffage portatif aliment au gaz n est pas ventil Il utilise l oxyg ne de l air ambiant Une circulation d air ad quate d...

Страница 10: ...OLVANTS DU DILUANT PEINTURE DES PARTICULES DE POUS SI RE OU DES PRODUITS CHIMIQUES INCONNUS L TAT DE LA CALIFORNIE IMPOSE L AVERTISSEMENT SUIVANT AVERTISSEMENT L UTILISATION DE CET APPAREIL CR E DES S...

Страница 11: ...ne le faites pasfonctionner s il n est plus dans son tat d origine 3 N ALLUMEZ PAS l appareil et ne le faites pas fonctionner moins que la coque soit compl tement ouverte et verrouill een position Con...

Страница 12: ...isezpas votre t l phone Faites vacuer imm diatement toute personne setrouvant dans l immeuble Utilisez le t l phone d un voisin et communiquez avecvotre fournisseur en gaz combustible et votre service...

Страница 13: ...N S TAPE 4 VERROUILLEZ LES CLIPS AU MOYEN DES TROIS VIS TEL QU ILLUSTR L APPAREIL NE DOIT PAS FONCTIONNER MOINS QUE LES COQUES EXT RIEURES SOIENT COMPL TEMENT OUVERTES ET VERROUILL ES EN POSITION ATTE...

Страница 14: ...la m thode d allumage 6 Quand la veilleuse reste allum e ouvrez le clapet bille tournez le en sens anti horaire pour allumer le br leur principal Fermez partiellement le robinet pour r gler le d bit...

Страница 15: ...eure 1 17 28643 Thermocouple 1 18 26433 Clapet limiteur de d bit POL 1 26568 Raccord 80CV 200CV 2008 1 28018 Raccord 80CV 200CV 2008 1 19 26255 R gulateur 1 R F N N ART Description Qt 20 21896 V lvula...

Страница 16: ...nsabilit totale de l entreprise Il n existe aucune autre garantie expresse ou tacite Plus pr cis ment il n y a aucune garantie concernant l ad quation une utilisation particuli re ni aucune garantie c...

Отзывы: