Danfoss TP9000 Programmable thermostat with timed Domestic
Hot Water (DHW) control:
Programmer dimensions: 135mm (W) x 88mm (H) x 32mm (D)
Room temperature sensor dimensions: 60mm (W) x 45mm (H) x 21mm (D)
Power supply: 220V/240V ac, 50Hz
Switch action 2 x SPDT, Type 1B. Switch rating 220/240V ac, 50/60Hz, 3(1)A
Power reserve: Minimum 24 hours
Memory back up retained for life of product
Enclosure rating: IP30
Control temperature range: Selectable 5 to 30°C
Holiday mode with room temperature setback
Timing accuracy: +/- 1 minute/month
Maximum ambient temperature: 45°C
Honeywell 2 Port motorised valves:
Model No.: V4043H
Voltage rating: 230V ac, 50HZ
Power consumption: 6W
Primary water temperature range: 5 to 88°C
Maximum ambient temperature: 52°C
Automatic differential by-pass valve:
Model No.: RWC DIFF 200 005
Setting range: 0 to 0.05 MPa (0 to 0.5 bar) differential pressure
Maximum primary water temperature: 110°C
Maximum operating pressure 1.0MPa (10 bar)
Graph 1 - Bypass valve pressure vs volume
Содержание PremierPlus SystemFit
Страница 1: ...PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual...
Страница 26: ...25...
Страница 27: ...26...