GUARANTEE

WARNING: Should the factory fitted temperature and pressure relief valve be tampered with or removed your 

guarantee will be invalidated. Neither the distributor nor manufacturer shall be responsible for any consequential 

damage howsoever caused.

Guarantee Terms                                                                                                                                                                                           

Heatrae Sadia guarantees the PremierPlus SystemFit against faulty manufacture or materials for a period of 2 years 

from the date of purchase including parts and labour. This 2 year guarantee is extended to 5 years for the expansion 

vessel and cold water control valve and to 30 years for the stainless steel inner vessel.

These guarantees are valid provided that:

The PremierPlus SystemFit has been installed by a competent installer and as per the instructions contained in the installation 

manual and all relevant Codes of Practice and Regulations in force at the time of installation.

Any disinfection has been carried out in accordance with BS 6700.

The PremierPlus SystemFit has not been modified in any way other than by heateam approved engineers.

The PremierPlus SystemFit has only been used for the storage of wholesome water (max. 250mg/l chloride).

The PremierPlus SystemFit has not been subjected to frost, nor has it been tampered with or been subjected to misuse or 

neglect.

No factory fitted parts have been removed for unauthorised repair or replacement.

The Benchmark

TM

 Commissioning Checklist  Service Record included in this product guide has been completed.

Regular maintenance has been carried out by a competent person in accordance with the requirements set out in the 

maintenance section of the installation manual and any replacement parts used should be authorised Santon spare parts. 

Annual services are available from heateam, the service division. Please contact heateam on Tel: 0844 871 1530 for further 

details.

Within 60 days of purchase the owner completes and returns the certificate supplied to register the product. Evidence of 

purchase and date of supply must be submitted upon making a claim.

This guarantee is not valid for installations outside the United Kingdom.

For installations outside of the United Kingdom, please contact either the Export Department on Tel: +44 1603 420271 or 

Baxi International on Tel: +44 1926 478323 for further details of the guarantee terms and conditions applicable. 

This guarantee does not affect your statutory rights.

The unit is not guaranteed against damage due to frost. 

ENVIROMENTAL

Products are manufactured from many recyclable materials. At the end of their useful life they should be disposed of at a 

Local Authority Recycling Centre in order to realise the full environmental benefits.

Insulation is by means of an approved CFC/HCFC free polyurethane foam with an ozone depletion factor of zero.

Содержание PremierPlus SystemFit

Страница 1: ...PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual...

Страница 2: ...ssioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist can be u...

Страница 3: ...controls are supplied pre wired A heating and domestic hot water programmer room temperature sensor primary expansion vessel automatic air vent and primary expansion relief valve are supplied loose fo...

Страница 4: ...can be correctly installed Areas that are subject to freezing must be avoided Ensure that the floor is of sufficient strength to support the full weight of the unit table 1 page 5 Pipe runs should be...

Страница 5: ...ions where it is not possible to safely pipe away any discharge from the safety valves In areas where the water consistently contains a high proportion of solids e g suspended matter that could block...

Страница 6: ...15 9 29 135 152 170 1245 691 1039 650 720 17 3 30 157 173 210 1503 952 1300 650 720 19 2 34 199 215 250 1755 1139 1460 650 720 18 6 42 240 257 300 2069 1460 1805 650 720 18 8 49 273 310 Notes 1 Heat...

Страница 7: ...IP30 Control temperature range Selectable 5 to 30 C Holiday mode with room temperature setback Timing accuracy 1 minute month Maximum ambient temperature 45 C Honeywell 2 Port motorised valves Model...

Страница 8: ...e note that if the key lock is disabled the circulator will not switch to setting selection In this case unlock the key lock by pressing the button for 10 seconds d During a period of 10 seconds press...

Страница 9: ...re The head pressure is kept constant irrespective of the heat demand The duty point of the circulator will move out or in on the selected constant pressure curve depending on the heat demand in the s...

Страница 10: ...There is no requirement to site it close to the unit it can be located at a point where the mains supply enters the premises if this is more convenient but you must install a non return valve just af...

Страница 11: ...s an accessory order code no 94 970 033 The secondary return pipe should be in 15mm pipe and incorporate a check valve to prevent backflow A suitable WRAS approved bronze circulation pump will be requ...

Страница 12: ...ply Incoming Cold Water Main KEY MCWS Mains cold water supply HWS Hot water service SC Stop Cock Isolating Valve DOC Drain Off Cock Discharge pipe to atmosphere Isolating Regulating Valves as required...

Страница 13: ...otal discharge form the discharge pipes connected to it 3 53 Where valves other than the temperature and pressure relief valve from a single unvented hot water system dischargeby way of the same manif...

Страница 14: ...ward discharges at low level i e up to 100mm above external surfaces such as car parks hard standings grassed areas etc are acceptable providing that a wire cage or similar guard is positioned to prev...

Страница 15: ...SIZE OF DISCHARGE PIPE D1 MINIMUM SIZE OF DISCHARGE PIPE D2 FROM TUNDISH MAXIMUM RESISTANCE ALLOWED EXPRESSED AS A LENGTH OF STRAIGHT PIPE i e NO ELBOWS OR BENDS RESISTANCE CREATED BY EACH ELBOW OR BE...

Страница 16: ...inal identification labels within the wiring centre to aid in connecting the various external system components such as the mains supply programmer and boiler The wiring to the external components is...

Страница 17: ...Y NOTES 1 ALLEARTHCONNECTIONSMUSTBELINKEDBACKTOTHEEARTHTERMINALSINTHEWIRINGCENTRE 2 ALLNEUTRALCONNECTIONSMUSTBELINKEDBACKTOTHENEUTRALTERMINALSINTHEWIRINGCENTRE 3 ASSUMESBASICBOILER 4 THE22MMMOTORISEDV...

Страница 18: ...ical supply to the PremierPlus SystemFit indirect controls and the boiler Programme the PremierPlus SystemFit controller as detailed in the fitting and user instruction leaflet supplied with the contr...

Страница 19: ...the outlet side of the bypass valve Turn the adjustment knob clockwise by half a turn MAINTENANCE MAINTENANCE REQUIREMENTS Unvented hot water systems have a continuing maintenance requirement in order...

Страница 20: ...hen water flows from the hot tap allow to flow for a short while to purge air and flush through any disturbed particles Close hot tap and then open successive hot taps in the system to purge any air W...

Страница 21: ...16 for adjustment details If in any doubt contact a competent electrician An immersion heater is also provided for use should the indirect heat source be shut down for any purpose The immersion heater...

Страница 22: ...OSSIBLE CAUSE REMEDY No hot water flow 1 Mains supply off 2 Check and open stock cock 2 Strainer blocked 2 Turn off water supply Remove strainer and clean see maintanance section 3 Cold water combinat...

Страница 23: ...mbined thermostat and thermal cut out Boiler 95 612 716 20 Combined thermostat and thermal cut out Immersion heater 95 612 717 21 Indirect thermal cut out 95 612 698 22 Motorised 2 port valve 22mm con...

Страница 24: ...23 Fig 9 Spares Diagram Fig 10 Pressure Reducing valve 3 5 bar Fig 11 Element spares Cold Mains Connection 22mm Outlet Connection 22mm 30 22 33 29 11 7 12 6 31 26 34 20 18 1 25 3 4 35 36...

Страница 25: ...itted parts have been removed for unauthorised repair or replacement The BenchmarkTM Commissioning Checklist Service Record included in this product guide has been completed Regular maintenance has be...

Страница 26: ...25...

Страница 27: ...26...

Страница 28: ...te responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the ne...

Отзывы: