GENERAL REQUIREMENTS

IMPORTANT: THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH 

REDUCED PHYSICAL SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE 

BEEN GIVEN SUPERVISORY OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND 

THE HAZARDS INVOLVED.  CHILDREN SHALL NOT PLAY WITH THE APPLIANCE.  CLEANING AND USER MAINTENANCE 

SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION.

WARNING: Do not switch on if there is a possibility that the water in the heater is frozen.

COMPONENT CHECK LIST

Before commencing installation check that all the components for your PremierPlus SystemFit unit are contained in the 

package. The following components are supplied with your PremierPlus Systemfit unit:

•  Factory fitted immersion heater(s) and thermal controls

•  Cold water combination valve (comprises pressure reducing valve, strainer, check valve) (supplied loose)

•  Factory fitted expansion core unit (comprises expansion valve and check valve)

•  Potable water expansion vessel (supplied loose) factory fitted temperature/pressure relief valve (set at 90°C/10 bar)

•  Tundish 

•  Factory fitted indirect thermostat and thermal cut-out

•  2 x 2-port motorised valve 

•  Primary circulating pump

•  Lock-shield flow balancing valve

•  Automatic bypass valve

•  Primary circuit filling loop

•  Primary circuit pressure gauge

•  Automatic air vent

•  Primary circuit expansion vessel (supplied loose)

•  CH/DHW programmer and room temperature sensor (supplied loose)

SITING THE UNIT

The PremierPlus SystemFit unit must be vertically floor mounted. It can be placed anywhere convenient provided the discharge 

pipe(s) from its safety valves can be correctly installed. Areas that are subject to freezing must be avoided. Ensure that the 

floor is of sufficient strength to support the “full” weight of the unit (table 1, page 5). Pipe runs should be kept as short as 

possible for maximum economy. Access to associated controls, immersion heaters and indirect controls should be possible 

for servicing and maintenance of the system.

To aid installation the PremierPlus SystemFit is provided with lifting points located in the base and top mouldings.  A floor 

template is also provided to aid positioning. 

If you choose to install the PremierPlus SystemFit in the highest point in the property (e.g. loft space), it is advisable to install 

an additional automatic air vent (AAV) (not supplied - available as spare, part number 95 605 050) above the pump to enable 

air to be removed from the system.  The addition of the AAV is not required if siting the cylinder in a lower position.

WATER SUPPLY 

Bear in mind that the water supply to the property will be supplying both the hot and cold water requirements simultaneously. 

It is recommended that the maximum water demand is assessed and the water supply checked to ensure this demand can 

be satisfactorily met.

NOTE:

 A high water pressure will not always guarantee high flow rates.

Wherever possible the PremierPlus 

Systemfit 

supply pipe should be 22mm. We suggest the minimum supply requirements 

should be 1.5 bar pressure and  20 litres per minute flow rate. However, at these values outlet flow rates may be poor if several 

outlets are used simultaneously. The higher the available pressure and flow rate the better the system performance.

The PremierPlus 

SystemFit 

cylinder has an operating pressure of 3.5 bar which is controlled by the cold water combination 

valve assembly. The cold water combination valve assembly can be connected to a maximum pressure of 16 bar.

Содержание PremierPlus SystemFit

Страница 1: ...PremierPlus SystemFit Unvented Indirect Hot Water Cylinder Installation and User Manual...

Страница 2: ...ssioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist can be u...

Страница 3: ...controls are supplied pre wired A heating and domestic hot water programmer room temperature sensor primary expansion vessel automatic air vent and primary expansion relief valve are supplied loose fo...

Страница 4: ...can be correctly installed Areas that are subject to freezing must be avoided Ensure that the floor is of sufficient strength to support the full weight of the unit table 1 page 5 Pipe runs should be...

Страница 5: ...ions where it is not possible to safely pipe away any discharge from the safety valves In areas where the water consistently contains a high proportion of solids e g suspended matter that could block...

Страница 6: ...15 9 29 135 152 170 1245 691 1039 650 720 17 3 30 157 173 210 1503 952 1300 650 720 19 2 34 199 215 250 1755 1139 1460 650 720 18 6 42 240 257 300 2069 1460 1805 650 720 18 8 49 273 310 Notes 1 Heat...

Страница 7: ...IP30 Control temperature range Selectable 5 to 30 C Holiday mode with room temperature setback Timing accuracy 1 minute month Maximum ambient temperature 45 C Honeywell 2 Port motorised valves Model...

Страница 8: ...e note that if the key lock is disabled the circulator will not switch to setting selection In this case unlock the key lock by pressing the button for 10 seconds d During a period of 10 seconds press...

Страница 9: ...re The head pressure is kept constant irrespective of the heat demand The duty point of the circulator will move out or in on the selected constant pressure curve depending on the heat demand in the s...

Страница 10: ...There is no requirement to site it close to the unit it can be located at a point where the mains supply enters the premises if this is more convenient but you must install a non return valve just af...

Страница 11: ...s an accessory order code no 94 970 033 The secondary return pipe should be in 15mm pipe and incorporate a check valve to prevent backflow A suitable WRAS approved bronze circulation pump will be requ...

Страница 12: ...ply Incoming Cold Water Main KEY MCWS Mains cold water supply HWS Hot water service SC Stop Cock Isolating Valve DOC Drain Off Cock Discharge pipe to atmosphere Isolating Regulating Valves as required...

Страница 13: ...otal discharge form the discharge pipes connected to it 3 53 Where valves other than the temperature and pressure relief valve from a single unvented hot water system dischargeby way of the same manif...

Страница 14: ...ward discharges at low level i e up to 100mm above external surfaces such as car parks hard standings grassed areas etc are acceptable providing that a wire cage or similar guard is positioned to prev...

Страница 15: ...SIZE OF DISCHARGE PIPE D1 MINIMUM SIZE OF DISCHARGE PIPE D2 FROM TUNDISH MAXIMUM RESISTANCE ALLOWED EXPRESSED AS A LENGTH OF STRAIGHT PIPE i e NO ELBOWS OR BENDS RESISTANCE CREATED BY EACH ELBOW OR BE...

Страница 16: ...inal identification labels within the wiring centre to aid in connecting the various external system components such as the mains supply programmer and boiler The wiring to the external components is...

Страница 17: ...Y NOTES 1 ALLEARTHCONNECTIONSMUSTBELINKEDBACKTOTHEEARTHTERMINALSINTHEWIRINGCENTRE 2 ALLNEUTRALCONNECTIONSMUSTBELINKEDBACKTOTHENEUTRALTERMINALSINTHEWIRINGCENTRE 3 ASSUMESBASICBOILER 4 THE22MMMOTORISEDV...

Страница 18: ...ical supply to the PremierPlus SystemFit indirect controls and the boiler Programme the PremierPlus SystemFit controller as detailed in the fitting and user instruction leaflet supplied with the contr...

Страница 19: ...the outlet side of the bypass valve Turn the adjustment knob clockwise by half a turn MAINTENANCE MAINTENANCE REQUIREMENTS Unvented hot water systems have a continuing maintenance requirement in order...

Страница 20: ...hen water flows from the hot tap allow to flow for a short while to purge air and flush through any disturbed particles Close hot tap and then open successive hot taps in the system to purge any air W...

Страница 21: ...16 for adjustment details If in any doubt contact a competent electrician An immersion heater is also provided for use should the indirect heat source be shut down for any purpose The immersion heater...

Страница 22: ...OSSIBLE CAUSE REMEDY No hot water flow 1 Mains supply off 2 Check and open stock cock 2 Strainer blocked 2 Turn off water supply Remove strainer and clean see maintanance section 3 Cold water combinat...

Страница 23: ...mbined thermostat and thermal cut out Boiler 95 612 716 20 Combined thermostat and thermal cut out Immersion heater 95 612 717 21 Indirect thermal cut out 95 612 698 22 Motorised 2 port valve 22mm con...

Страница 24: ...23 Fig 9 Spares Diagram Fig 10 Pressure Reducing valve 3 5 bar Fig 11 Element spares Cold Mains Connection 22mm Outlet Connection 22mm 30 22 33 29 11 7 12 6 31 26 34 20 18 1 25 3 4 35 36...

Страница 25: ...itted parts have been removed for unauthorised repair or replacement The BenchmarkTM Commissioning Checklist Service Record included in this product guide has been completed Regular maintenance has be...

Страница 26: ...25...

Страница 27: ...26...

Страница 28: ...te responsibility and sustainability charters and reduce our printed material we encourage you to download product brochures from our website In designing these files we have taken into account the ne...

Отзывы: