![Heatrae Sadia Handy 3 NT Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/heatrae-sadia/handy-3-nt/handy-3-nt_fitting-instructions-manual_2117646006.webp)
6
Nominal Power Rating
Model
240V
230V
Minimum
cable size
3.1kW
3.1kW
12.9 amp
2.9kW
12.4 amp
1.5mm
2
Materials
Backplate and cover assembly - ABS
Element(s) - Copper sheathed rod type.
Dimensions
Height - 235mm
Width - 151mm
Depth - 85mm
Standards and approvals
Complies with the requirement of EN 60335-2-35.
Complies with European Community Directives
(CE). kiwa approved.
3.3 Electrical diagram(s)
Red or brown to 'L'
Green & yellow to
Blue or black to 'N'
Cable clamp
Figure 2 – Electrical connection
Figure 3 – Wiring diagram
Neon
Inner
container
Red
Red
Red
Cut
Out
Terminal
block
N
L
Red
Red
Red
Pressure
switch
3.1kW
Black
Black
Black
Black
Green/Y
ellow
Solenoid
valve
PCB Infra-red
L
L
N
N
{
{
Solenoid
PCB