8.0 INSTALLATION – DISPENSING TAP CONNECTION
8.1 The hot supply hose should be connected to the OUTLET hose spigot of the Aquatap
water heating unit.
The hose should rise continuously from the heater to the tap
without kinks or twists.
If necessary it can be cut to a shorter length, but it should
never be lengthened. The hose should be secured in place on the spigot using the clamp
provided.
Warning: Only use the hose supplied with the unit or a WRAS approved hose.
Spare hose and clips can be ordered, product code 95607364.
8.2
The VENT hose should be connected to the VENT hose spigot of the Aquatap water
heating unit.
The hose should rise continuously (vertical) from the heater to the tap
without kinks or twists.
If necessary it can be cut to a shorter length, but it should
never be lengthened.The hose should be secured in place on the spigot using the clamp
provided.
8.3
The Ambient hose should be connected to the cold hose spigot of the Aquatap water
heating unit.
The hose should rise continuously from the heater to the tap without
kinks or twists
. If necessary it can be cut to a shorter length, but it should never
be lengthened. The hose should be secured in place on the spigot using the clamp
provided.
CLAMP
HOT TAP
OUTLET
HOSE
FLEXIBLE
HOSE
TAP
VENT
HOSE
FIGURE 7: TAP MOUNTING (BOIL & AMBIENT)
CLAMP
1.5mm² 3 CORE HO5 VV-F
SHEATHED CABLE
COLD WATER
SUPPLY
DISPENSER CABLE
CONNECTOR
WHITE HOSE
(NOTE: DRIP TRAY/SINK NOT SHOWN FOR CLARITY)
AMBIENT
OUTLET
HOSE
DISTANCE BETWEEN TAP AND HEATER
AS SHORT AS POSSIBLE TO ENSURE
CONNECTING PIPES RISE CONTINUOUSLY
Содержание Aquatap Boil and Ambient
Страница 1: ...Aquatap Boil and Chill Boil and Ambient Installation and user manual...
Страница 21: ...21 FIGURE 15 EXPLODED VIEW FOR STEAM TRAP REMOVAL AND DESCALING...
Страница 25: ...25 1 1 FIGURE 16 EXPLODED VIEW OF DISPENSER 1 3 2 4 1 1 1...
Страница 26: ...26 FIGURE 17 EXPLODED VIEW HEATER ASSEMBLY 14 12 16 10 13 15 11 17 18 21 20 45 21 21 18 46...
Страница 27: ...27 FIGURE 18 EXPLODED VIEW HEATER ASSEMBLY 22 25 25 26 27 9 24 23 38 50...
Страница 28: ...FIGURE 19 EXPLODED VIEW HEATER 28 29 30 31 9 28...
Страница 29: ...29 32 FIGURE 20 EXPLODED VIEW HEATER...
Страница 33: ...33 NOTES...
Страница 34: ...34 NOTES...
Страница 35: ...35 NOTES...