WIRING CONNECTIONS
HeatNet Control REV 1.38-1
Page 37
Figure 30
Heating Method 5 MODBUS (Optional BACnet or LonWorks bridge)
Shielded or Twisted
pair wire to Building
Management System
Protocessor Bridge Module Plug-in.
LonWorks or BACnet bridge which
Can be used instead of the
MODBUS input.
Shieded or Twisted Pair
Connection (MSTP/
LonWorks)
RJ45 Configuration
and IP connection
DIP Switch shown :Not
Terminated
Push both white switches down to
enable BACnet, Lonworks, or
Modbus termination.
There are pin headers located on the control (‘U’ shaped) that
the Protocessor bridge module plugs in directly. Align the
sockets on the Protocessor with the pin headers on the
control, then press into place. All power for the bridge is
supplied by the version 2.x control. Communication from the
Protocessor bridge to the H-Net control is also handled
through the sockets.
Next, connect the BACnet or LonWorks network cable to the
Protocessor module or configure the bridge using the
software tools. Once connected use the DIP switch to enable
termination.
NOTE:
Do not plug the Protocessor
module in with power on or
Protocessor module may be damaged.
Additional Bulletins and Instructions for Configuring BACnet or LonWorks are available on the website.
A
C
G
N
D
1 AMP
VFD
OUTPUT
O
U
TP
U
T
DHW PUMP/
D
H
W
T
A
N
K
AUX STATUS
Aux Status/
+
PUMP/VALVE
M
O
D
B
U
S
H
N
E
T
A
L
R
M
R
S
T
D
A
M
P
E
R
H
E
A
D
E
R
R
E
T
U
R
N
S
U
P
P
L
Y
P
W
M
/0
-1
0
4-
20
m
a
8
SPARE 4
LWCO
-
+
-
+
-
+
-
+
-
+
-
+
KNSMITH R1.0
KN/F-SERIES
PUMP
1
1
1
1
1
1
8
10
1
8
8
1
1
1
1
RET
DISPLAY/KEYPAD
DAMPER
HEAT
ALARM
DEMAND
ALARM
LOCAL PUMP
DAMPER
SYSTEM PUMP
T2
T1
OR OVR
AA
LOCAL
DAMPER
SYSTEM
S
Y
S
T
E
M
HI/LO NO
24
V
D
C
4
-
2
0
m
A
24
V
D
C
S
P
A
R
E
2
W
T
R
O
U
T
O
U
T
S
ID
E
0-1
0V
D
C
EXT OPERAT
VFD
WTR FLW
GAS PR
SYSTEM
24V
24V
BOILR START
24VAC TRANSFORMER
PILOT VALVE
MAIN VALVE
HIGH LIMIT
Unused
4-20ma
PWM/0-10
1
1
8
+
-
A
IR
W
T
R
I
N
AIR PR SW
VALVE ALRM
FLAME SAFE
IN
TE
R
LO
C
K
S
ENABLE
HIGH FIRE
R
E
T
4-20mA/
CAL
NORM
PWM
0-10
WTR FLOW
LOCAL
0-10v
A
+
B
-
G
A
+
B
-
G
A
+
B
-
G
ALARM
OPTION
S
en
se
24
V
A
C
DHW PUMP
LOW FIRE
L2
L1
L1
3
P
O
W
E
R
S
E
R
V
IC
E
L2
A
C
G
N
D
1
02-2008
OPERATOR
O
U
TP
U
T
0-1
0V
D
C
W
B
R
MODULATION CONTROL
-
4-20mA
BLOWER M
IG
N
IT
IO
N
C
O
N
TR
O
L
Unused
1
1
1
1
Ju
m
pe
r 2
-3
fo
r 1
35
o
hm
2
3
HEAT NET
K
8
J2
2
J2
0
J6
D
5
D
4
K7a
T7
7_
R
E
LA
Y
K7
J2
S
4
S2
SIP1
20
19
1
2
J9
F3
J1
0B
U
26
J12A
J12B
J13
J1
0A
F1
J4
J1
6
J18
J1
9
J1
4
K1
K4
K5
K6
K2
BZ1
JP
3
K1a
T7
7_
R
E
LA
Y
K2a
T7
7_
R
E
LA
Y
K4a
T7
7_
R
E
LA
Y
K5a
T7
7_
R
E
LA
Y
K6a
T7
7_
R
E
LA
Y
J10
J1
1
J1
2
S
3
J8
J1
7
Y
1
S1
J2
1
JP4
U4
PROTOCESSOR
JP
S
1
J1
J5
A
J5
B
J3
J5
Modbus
Modbus RJ45
Содержание Smith Series
Страница 33: ...WIRING CONNECTIONS HeatNet Control REV 1 38 1 Page 33 Wiring Connections Figure 26 Power Connections...
Страница 65: ...OPERATION HeatNet Control REV 1 38 1 Page 65 Smith Series Run Screen...
Страница 68: ...OPERATION HeatNet Control REV 1 38 1 Page 68 Smith Series Menu Tree Version 1 38...
Страница 81: ......
Страница 82: ...Smith 260 North Elm Street Westfield MA 01085...