background image

13

Wireless 

Series

Section Header

Room Temperature 

SET Temperature

Temperature Display

This is the current room temperature. 

This is the temperature you are trying to 
achieve in your home.

The temperature display information is driven by two different inputs; the sensor 
measurement and the target temperature you have set.

Timer On / Timer Off - This is the status of the hot water output.

Содержание Touch-RF

Страница 1: ...Model Touch RF...

Страница 2: ...1 Wireless Series Model Touch RF...

Страница 3: ...ed Clean Hot Water Timings Explained Clean Screen What is a Programmable Room Thermostat LCD Display Temperature Display Pairing With The UH8 RF Product Image Hot Water Timings Explained 18 19 19 20 2...

Страница 4: ...on It will allow you to select different temperatures in your home at different times of the day and days of the week to meet your particular needs and preferences Setting a room thermostat to a highe...

Страница 5: ...rooms by installing thermostatic radiator valves TRVs on individual radiators If you don t have TRVs you should choose a temperature that is reasonable for the whole house If you do have TRVs you can...

Страница 6: ...rmostat from the wall plate Step B Release the desk stand Do Mount the thermostat at eye level Read the instructions fully so you get the best from our product Don t Do not push hard on the LCD screen...

Страница 7: ...Section Header Model Touch RF 6 1 2 A B...

Страница 8: ...7 Wireless Series Section Header 1 4 3 2 5 10 11 12 20 19 16 6 13 14 9 15 18 21 7 8 17...

Страница 9: ...e heating is switched off and system is protecting against frost only 11 RF Icon Flashes when the thermostat communicates with the receiver 12 Battery Icon Indicates current battery charge level 13 Ro...

Страница 10: ...heating and hot water mode the hot water output will automatically pair to channel 2 HW On the RF Switch receiver press and hold the CH1 Pairing button if a valve is used or Boiler CH Pairing button...

Страница 11: ...re 00 UH1 W or 01 RF Switch receiver Use the Up Down keys centre screen to set feature 06 to 00 UH8 RF Press the Up key at the top of the screen to select feature 07 Use the Up Down keys to set the la...

Страница 12: ...ating 01 Radiators Press the DONE key You will now see the flame icon and after a few seconds the RF symbol will appear The assigned zone on the UH8 RF should now be active If the output on the UH8 RF...

Страница 13: ...follow these steps Press PROG Press CLOCK Use the Down key to set the hours Use the Up key to set the minutes Use the Day key to set the day of the week Press DONE to confirm and exit Setting the Clo...

Страница 14: ...is the current room temperature This is the temperature you are trying to achieve in your home The temperature display information is driven by two different inputs the sensor measurement and the tar...

Страница 15: ...y Programming 4 levels for the weekdays and 4 different levels for the weekend 7 Day Programming 4 levels for each day 24 hours 4 levels 7 days a week See pages 25 26 for details on how to switch betw...

Страница 16: ...Repeat these steps for the LEAVE RETURN SLEEP periods Press DAY to select the next day to program and repeat When complete press DONE to confirm settings and exit In 5 2 Day mode the thermostat will d...

Страница 17: ...4 levels for each day 24 hours 4 levels 7 days a week See pages 26 27 for details on how to switch between these modes Tip If you don t want to use all of the comfort levels just set the time to Defau...

Страница 18: ...t the OFF time for period 1 Repeat these steps for periods 2 3 and 4 Press DAY to select the next day to program and repeat When complete press DONE to confirm settings and exit In 5 2 Day mode the th...

Страница 19: ...ttom right corner of the display and hold for 10 secs When activated you will see the Keypad Lock symbol To cancel press the bottom right corner of the display again for 10 secs Keypad Lock Indicator...

Страница 20: ...ntained only until the next programmed comfort level At this time the thermostat will revert back to the programmed levels To override the hot water setting follow these steps Press HOLD Press TIMER I...

Страница 21: ...e current operating program and set a different temperature for a desired period Press HOLD Use the top set of Up Down keys set the hold period Use the center set of Up Down keys to set the hold tempe...

Страница 22: ...atically return to the program mode on your return Press HOLIDAY Enter the desired duration in days Press DONE to confirm settings and exit Note A holiday period does not start until 00 00 the next da...

Страница 23: ...ct mode In this mode the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature see page 24 Should the heating be tur...

Страница 24: ...uirement for heating to achieve the set temperature but the thermostat remains active To turn the thermostat OFF completely press and hold the Power button The display and heating output will be turne...

Страница 25: ...ntained when the thermostat is in frost mode The range is 07 17 C The default is 12 C and is suitable for most applications Feature 05 Output Delay To prevent rapid switching an output delay can be en...

Страница 26: ...ent to avoid unnecessary heating and ensure the building is warm at the programmed time The thermostat uses the rate of change information to calculate how long the heating needs to raise the building...

Страница 27: ...Press PROG Press SETUP Use the Up Down keys at the top of the screen to select the feature number shown on page 27 and then use the Up Down keys in the center to adjust the setting Press DONE to conf...

Страница 28: ...00 UH8 RF 01 RF Switch 00 Default UH8 RF 01 99 UH8 RF 01 08 RF Switch Not Used Underfloor Heating 00 Radiator Zone 01 00 Disabled 01 Enabled 01 Default 00 10 C 00 C Default Not Used Not Used 00 03 ho...

Страница 29: ...these steps Press and hold the Power key to turn the thermostat OFF Press and hold the OFF key until the temperature appears on screen Use the Up Down keys to configure the new temperature Press DONE...

Страница 30: ...llow these steps Turn the thermostat OFF by pressing and holding the Power button Press and hold the bottom left corner of the LCD for 10 seconds All of the screen icons will appear for 2 seconds and...

Страница 31: ...attery can provide power for up to 6 months before recharging is required in normal operating conditions To recharge the battery you need to connect the thermostat to a power source A mini USB to USB...

Страница 32: ...31 Wireless Series Section Header...

Страница 33: ...Model Touch RF 32 Notes...

Страница 34: ...Model Manual REF 33 Notes 33 Wireless Series...

Страница 35: ...Model Touch RF 34 Notes...

Страница 36: ...More Information PDF FAQ Call our support team on 44 0 1254 669090 Or view technical specifications directly on our website www heatmiser com Twitter heatmiseruk Facebook facebook com thermostats Rev...