Section Header
32
Model:
Re-calibrating the Thermostat
If you need to re-calibrate the thermostat, follow these steps.
• Use the Left / Right keys to scroll to the Power Icon ...........................
• Press and hold Tick to turn the display OFF ..........................................................
• Press and hold the Tick and Down keys together for 10 seconds .................
• The current temperature will appear on the display.
• Use the Up / Down keys to configure the new temperature value .............
• Press the Tick key to confirm the change and the display will go blank ....
• Press the Tick key once to turn the thermostat ON ..................................
..........
E0 = The internal sensor has developed a fault.
E2 = The remote AIR probe has not been connected.
The remote AIR probe has not been wired correctly.
The remote AIR probe is faulty.
When terminated for thermostat operation the screen will display an error code if a
fault is detected.
Error Codes
Содержание neoAir
Страница 1: ...Model ...
Страница 2: ...1 Series Model ...
Страница 7: ...Section Header 6 Model 1 2 3 4 ...
Страница 15: ...Section Header 14 Model Modes 1 3 Thermostat Thermostat with Hot Water ...
Страница 16: ...15 Series Section Header 1 3 14 15 16 2 5 6 7 4 8 9 13 12 10 11 FLOOR TEMP ROOM TEMP ...
Страница 35: ...Section Header 34 Model 1 10 9 4 5 2 11 8 7 3 6 Mode 2 Time Clock ...
Страница 41: ... Model 40 Notes ...
Страница 42: ... Model Manual REF 41 Notes 41 Series ...
Страница 43: ... Model 42 Notes ...