Optional Features Explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED
Feature 01 – Pairing To neoHub:
This function is used to connect the thermostat to the
neoHub.
Feature 02 - Switching Differential:
This function allows you to increase the switching
differential of the thermostat. The default is 1°C which means that with a set temperature
of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C. With a 2°C
differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 - Frost Protect Temperature:
This is the temperature maintained when the
thermostat is in Frost Mode. The range is 07 - 17°C. The default is 12°C and is suitable for
most applications.
Feature 04 – Output Delay:
To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit:
This function allows you to limit the use of the
up and down temperature arrow keys. This limit is also applicable when the thermostat is
locked and so allows you to give others limited control over the heating system.
Feature 06 – Sensor Selection:
On this neoAir, you can select which sensor should be
used. You can select between air temperature only, floor temperature, or both. When you
enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to
prevent the floor from overheating.
Feature 07 – Floor Temp Limit:
This function is available when feature 06 is set to 03. You
can set a floor limiting temperature between 20-45°C (28°C is the default setting). Note:
neoAir MUST NOT be used to control electric under-floor heating.
Содержание neoAir
Страница 1: ...Model ...
Страница 2: ...1 Series Model ...
Страница 7: ...Section Header 6 Model 1 2 3 4 ...
Страница 15: ...Section Header 14 Model Modes 1 3 Thermostat Thermostat with Hot Water ...
Страница 16: ...15 Series Section Header 1 3 14 15 16 2 5 6 7 4 8 9 13 12 10 11 FLOOR TEMP ROOM TEMP ...
Страница 35: ...Section Header 34 Model 1 10 9 4 5 2 11 8 7 3 6 Mode 2 Time Clock ...
Страница 41: ... Model 40 Notes ...
Страница 42: ... Model Manual REF 41 Notes 41 Series ...
Страница 43: ... Model 42 Notes ...