Optional Settings - Feature Table
P3
P2
P1
01
Menu
Entry Point
02
03
04
05
06
07
08
09
10
11
12
13
FEATURE
Failsafe
Pairing to UH8-RF
Pairing to RF-Switch
Pairing to Hub
Switching Differential
Frost Protection Temperature
Output Delay
Up/Down Temperature Limit
Sensor Selection
Floor Temperature Limit
Optimum Start
Rate of Change
Not used on this model
Not used on this model
Program Mode
Temperature Format
DESCRIPTION
00 = Disabled
01 = Enabled (Default)
00 – 99 = Receiver address
Commences countdown from 99 – 00 seconds.
Used to add zone to the neoHub
00 = 0.5°C
01 = 1.0°C (Default)
02 = 2.0°C
03 = 3.0°C
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
00° - 10°C (00 = Default)
00 = Built in Sensor (Default)
01 = Remote Air Sensor
02 = Remote Floor Sensor
03 = Built in Sensor & Remote Floor
20°C - 45°C (28°C = Default)
00 - 05 Hours (00 = Default)
Minutes to raise by 1°C
00 = Non - Programmable
01 = Weekday/Weekend (Default)
02 = 7 Day Programming
03 = 24 Hour Mode
00 = °C, 01 = °F (00 = Default)
SETTING
Содержание neoAir
Страница 1: ...Model ...
Страница 2: ...1 Series Model ...
Страница 7: ...Section Header 6 Model 1 2 3 4 ...
Страница 15: ...Section Header 14 Model Modes 1 3 Thermostat Thermostat with Hot Water ...
Страница 16: ...15 Series Section Header 1 3 14 15 16 2 5 6 7 4 8 9 13 12 10 11 FLOOR TEMP ROOM TEMP ...
Страница 35: ...Section Header 34 Model 1 10 9 4 5 2 11 8 7 3 6 Mode 2 Time Clock ...
Страница 41: ... Model 40 Notes ...
Страница 42: ... Model Manual REF 41 Notes 41 Series ...
Страница 43: ... Model 42 Notes ...