16
Feature 09 – Floor Limit
: When the thermostat is operating
in mode 01 and 03 (as described on page 13) and function 08
is set to 02, 03 or 04, function 09 becomes available. You can
then set the maximum floor temperature limit - 20-45°C (28°C
default).
Feature 10 – Optimum Start
: Optimum start will delay the
start up of the heating system to the latest possible moment to
avoid unnecessary heating, so that the dwelling is comfortably
warm by the programmed time. The thermostat uses the rate of
change (see below) setting to calculate how long the building
needs to take to raise the building 1°C (with a rate of change
of 20, the thermostat has calculated the building needs 20
minutes to raise the building 1°C).
Feature 11 – Rate of Change
: For information only.
Feature 12 – Weekday/Weekend or 7 Day Programming
:
The thermostat offers two programming methods. Weekday/
Weekend allows you to program 4 comfort levels for the
weekday and 4 different comfort levels for the weekend. In 7
day program mode, each day has 4 comfort levels that can be
programmed independently.