background image

COMMUNITY BARBECUE

 

1

6

A-0060-MAN Heatlie Community Barbecue Instruction Manual V2 Updated Dec 2021

Problem

Possible Cause

Remedy

Barbecue does 

not light

Gas supply problem

D

epress the start button for a few 

seconds before attempting to 

light to allow more gas to flow.

Check cylinder valve is open.

Check gas bottle is not empty.

 

Check hose is connected at 

bayonet fitting.

Check Natural Gas line is 

functional and turned on.

The electrode is too far 

away from the burner

Wire probe needs to be 4-5mm 

away from the burner and over a 

slot in the burner

.

The electrode is not 

sparking

Ensure the lead is connected 

securely to the piezo

.

Burner lights but 

does not stay 

lit

Gas supply problem

Check cylinder valve is open

.

Check gas bottle is not empty

.

 

Check hose is connected at 

bayonet fitting

.

Check Natural Gas line is 

functional and turned on

.

Gas control valve 

problem

Ensure the knob turns freely and is 

on HIGH 

for ignition

.

Thermocouple is not 

positioned correctly

Thermocouples need to be 

positioned in the flame, 3-5mm 

above the burner slots

.

Flame is low, 

excessively 

yellow and/or 

depositing soot 

on under side of 

plate

Gas supply problem

Low pressure may result from the 

gas cylinder being close to empty

.

 

Change to a full gas cylinder.

 

C

onfirm hard gas line is delivering 

correct pressure.

Blocked burners

Clean burners by blowing high 

pressure air through the burner or 

with a wire brush.

Inspect gas valve for blockage 

caused by insects or spiders  

for example

Burner flame is starved 

of air

Ensure 

b

arbecue is ventilated 

correctly

.

TROUBLE-
SHOOTING

If any of the above conditions cannot be rectified, contact the place of 
purchase or Heatlie Barbecues.

The timer unit 

doesn't

 

'

b

eep'

 

when lighting

(

the 

barbecue

can 

ignite

 but 

extinguishes 

when button 

released)

.

Thermopile is not 

postioned correctly

Thermocouple is not 

positioned correctly

Timer unit failure

Thermocouples need to be 

positioned in the flame, 3-5mm 

above the burner slots

Thermopiles need to be 

positioned in the flame, 3-5mm 

above the burner slots

Replacement timer unit is 

required. 

I

f gas fitter is 

unavailable to change, SBI 

changeover is required.

Содержание COMMUNITY BARBECUE CBBQ 600

Страница 1: ...COMMUNITY BARBECUE SERIES CBBQ 600 CBBQ 850 Instructions and General Information ...

Страница 2: ...ral Gas required for your use This will be clearly marked on the carton and on the product If you have purchased the Serviceable Burner Insert SBI then please refer to the instructions in this manual for replacement Be sure to read the Warranty Policy and understand these conditions WARRANTY REGISTRATION If not purchased through Heatlie complete the Product Register form located under Customer Hel...

Страница 3: ...In An Outdoor Area 12 Using the Barbecue Plate Cleaning Seasoning 13 Lighting Instructions 15 Maintenance Instructions 14 Cooking Instructions 16 Trouble Shooting 14 Cleaning Instructions 7 Installation Cabinet Preparation 9 CBBQ 600 Bench Preparation and Installation 10 CBBQ 850 Bench Preparation and Installation 11 Connecting To A Gas Supply 18 Warranty Policy 17 Gas Consumption ...

Страница 4: ...COMMUNITY BARBECUE 4 A 0060 MAN Heatlie Community Barbecue Instruction Manual V2 Updated Dec 2021 CBBQ 600 CBBQ 850 ...

Страница 5: ...TE Template for bench cut out If you are installing the barbecue in a bench top please retain the template provided in the barbecue box marked Template for cut out Visual references of these templates can be found on page 9 CBBQ 600 and page 10 CBBQ 850 UNPACKING THE BOX SAFETY PRECAUTIONS If the information in this manual is not followed exactly a fire or explosion may result causing property dam...

Страница 6: ...lls Figures F2 and F3 Within a partial enclosure that includes an overhead cover and more than two walls with the following also applying Figures F4 and F5 i At least 25 of the total wall area is completely open and unrestricted ii At least 30 of the remaining wall area is open and unrestricted In the case of balconies at least 20 of the total of the side back and front wall areas are to be open a...

Страница 7: ...in the 75mm exclusion area below the barbecue Examples of Non combustible materials are Steel Stainless Steel Caesar Stone Granite Brick Ventilation Requirements A minimum ventilation area of 1930cm2 CBBQ 600 or 2530cm2 CBBQ 850 between the barbecue and open air is required for both LPG and Natural gas applications It is recommended that the underside of the BBQ be left completely unrestricted and...

Страница 8: ... is connected to a main gas supply Natural Gas a separate compartment is not required A 40mm diameter hole is required on the rear of the cabinet on the side which has the control knob to allow access to the natural gas connection The hole should not be more than 40cm above the base of the cabinet Refer to AS5601 for pipe sizing details ...

Страница 9: ... requirements on page 6 7 CBBQ600 Installation 1 Carefully lower the barbecue into the opening in the bench top 2 Push the barbecue into the cavity to ensure all trim edges are flush with the mounting faces It must be located centrally in the cutout 3 Secure the barbecue in place using the supplied Tek screws or equivalent fasteners DO NOT exceed maximum screw depth into the barbecue of 15mm 4 Con...

Страница 10: ... meet the requirements on page 6 7 CBBQ850 Installation 1 Carefully lower the barbecue into the opening in the bench top 2 Push the barbecue into the cavity to ensure all trim edges are flush with the mounting faces it must be located centrally in the cutout 3 Secure the barbecue in place using the supplied Tek screws or equivalent fasteners DO NOT exceed maximum screw depth into the barbecue of 1...

Страница 11: ... connected directly to a natural gas piped supply Whilst the Barbecue can be converted you will need to contact Heatlie Barbecues or your nearest stockist or for details on parts required Natural Gas Connection Where the barbecue is supplied for use with Natural Gas a hose fitting complying to AS1869 is attached This has a 1 4 BSP internal thread on one end and a bayonet fitting at the other for c...

Страница 12: ...ash again The plate cannot be left without oil on it i e it must be seasoned once the lanolin is removed Seasoning the Barbecue Plate Grill Plate The Heatlie Community Barbecue Plate is made of stainless steel or mild steel and both need to be seasoned prior to use This will reduce the likelihood of food sticking to the plate and ensure longevity of the plate This is a similar process to seasoning...

Страница 13: ...nob to HIGH position 2 Over 10 seconds Push and HOLD panel waiting for Click to light burner 3 Keep HOLD of the panel and LOOK through view hole figure 11 for flame Repeat step 2 until lit 4 Continue to HOLD the start button until a BEEP is heard to indicate the timer has started 5 Slowly RELEASE the start button The BBQ should stay lit 6 The BBQ will stay lit for 11 minutes 7 The BBQ will BEEP 3 ...

Страница 14: ...apply a layer of cooking oil Avoid washing the plate with water Clean the trim of the barbecue with a soft cloth and a commercially available stainless steel cleaner when possible The internal drawer area can be cleaned with a commercially available barbecue cleaner The stainless steel plates will darken or dis colour with use This is typical of stainless steel barbecue plates Ensure the internal ...

Страница 15: ...val steps 10 Secure the removed SBI into the packaging and return to Heatlie for servicing Use the From address located on the packaging FIGURE 13 FIGURE 14 FIGURE 15 FIGURE 16 Instructions for Removal Installation of the Serviceable Burner Insert SBI for both CBBQ 600 and CBBQ 850 MAINTENANCE INSTRUCTIONS NOTE This is located on the Gas Cylinder for LPG systems Some Natural Gas system isolation v...

Страница 16: ...correctly Thermocouples need to be positioned in the flame 3 5mm above the burner slots Flame is low excessively yellow and or depositing soot on under side of plate Gas supply problem Low pressure may result from the gas cylinder being close to empty Change to a full gas cylinder Confirm hard gas line is delivering correct pressure Blocked burners Clean burners by blowing high pressure air throug...

Страница 17: ... Type Natural Gas Universal LPG Injector Diameter 1 60mm 0 90mm Burner Pressure 1 00kPa 2 75kPa Nominal Hourly Gas Consumption per burner 10 MJ hr 9 MJ hr NHGC Total 20 MJ hr 18 MJ hr Gas Type Natural Gas Universal LPG Injector Diameter TBD TBD Burner Pressure TBD TBD Nominal Hourly Gas Consumption per burner TBD TBD NHGC Total TBD TBD ...

Страница 18: ... Installation must conform to the applicable gas and building standards laid down by the country or state and according to the Heatlie product installation guide and instructions 5 This warranty policy does not cover problems associated with corrosion 6 This warranty policy does not cover buckling or warping of the hotplate 7 Lack of maintenance abuse misuse neglect accident or improper installati...

Страница 19: ...and manufactured by M A Mead Investments Pty Ltd t as Heatlie Engineering ABN 55 111 671 008 60 Kinkaid Ave NORTH PLYMPTON SA 5037 Phone 08 8376 9330 Email Address info heatlie com au Web Page www heatlie com au ...

Отзывы: