COMMUNITY BARBECUE
1
6
A-0060-MAN Heatlie Community Barbecue Instruction Manual V2 Updated Dec 2021
Problem
Possible Cause
Remedy
Barbecue does
not light
Gas supply problem
D
epress the start button for a few
seconds before attempting to
light to allow more gas to flow.
Check cylinder valve is open.
Check gas bottle is not empty.
Check hose is connected at
bayonet fitting.
Check Natural Gas line is
functional and turned on.
The electrode is too far
away from the burner
Wire probe needs to be 4-5mm
away from the burner and over a
slot in the burner
.
The electrode is not
sparking
Ensure the lead is connected
securely to the piezo
.
Burner lights but
does not stay
lit
Gas supply problem
Check cylinder valve is open
.
Check gas bottle is not empty
.
Check hose is connected at
bayonet fitting
.
Check Natural Gas line is
functional and turned on
.
Gas control valve
problem
Ensure the knob turns freely and is
on HIGH
for ignition
.
Thermocouple is not
positioned correctly
Thermocouples need to be
positioned in the flame, 3-5mm
above the burner slots
.
Flame is low,
excessively
yellow and/or
depositing soot
on under side of
plate
Gas supply problem
Low pressure may result from the
gas cylinder being close to empty
.
Change to a full gas cylinder.
C
onfirm hard gas line is delivering
correct pressure.
Blocked burners
Clean burners by blowing high
pressure air through the burner or
with a wire brush.
Inspect gas valve for blockage
caused by insects or spiders
for example
Burner flame is starved
of air
Ensure
b
arbecue is ventilated
correctly
.
TROUBLE-
SHOOTING
If any of the above conditions cannot be rectified, contact the place of
purchase or Heatlie Barbecues.
The timer unit
doesn't
'
b
eep'
when lighting
(
the
barbecue
can
ignite
but
extinguishes
when button
released)
.
Thermopile is not
postioned correctly
Thermocouple is not
positioned correctly
Timer unit failure
Thermocouples need to be
positioned in the flame, 3-5mm
above the burner slots
Thermopiles need to be
positioned in the flame, 3-5mm
above the burner slots
Replacement timer unit is
required.
I
f gas fitter is
unavailable to change, SBI