20. SUPPORTED COMMAND CLASSES

The following table lists all Command Classes supported by the Z-Wave 

Device. The device supports both S0, S2 Authenticated security and S2 

Unauthenticated security.

INSECURE 

INCLUSION

INSECURE 

ON SECURE 

INCLUSION

SECURE 

ON 

SECURE 

INCLUSION

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

Yes

Yes

Yes

COMMAND_CLASS_ASSOCIATION_V2

Yes

Yes

COMMAND_CLASS_MULTI_CHANNEL_
ASSOCIATION_V2

Yes

Yes

COMMAND_CLASS_ASSOCIATION_GRP_
INFO_V3

Yes

Yes

COMMAND_CLASS_TRANSPORT_
SERVICE_V2

Yes

Yes

COMMAND_CLASS_VERSION_V3

Yes

Yes

COMMAND_CLASS_MANUFACTURER_SPE-
CIFIC_V2

Yes

Yes

COMMAND_CLASS_DEVICE_RESET_
LOCALLY_V1

Yes

Yes

COMMAND_CLASS_INDICATOR_V3

Yes

Yes

COMMAND_CLASS_POWERLEVEL_V1

Yes

Yes

COMMAND_CLASS_BATTERY_V1

Yes

Yes

COMMAND_CLASS_SECURITY_V1

Yes

Yes

COMMAND_CLASS_SECURITY_2_V1

Yes

Yes

COMMAND_CLASS_NOTIFICATION_V8

Yes

Yes

COMMAND_CLASS_SUPERVISION_V1

Yes

Yes

COMMAND_CLASS_FIRMWARE_
UPDATE_MD_V5

Yes

Yes

COMMAND_CLASS_THERMOSTAT_MODE_
V3

Yes

Yes

COMMAND_CLASS_THERMOSTAT_SETPO-
INT_V3

Yes

Yes

COMMAND_CLASS_THERMOSTAT_
OPERATING_STATE_V1

Yes

Yes

COMMAND_CLASS_PROTECTION_V1

Yes

Yes

COMMAND_CLASS_CONFIGURATION_V4

Yes

Yes

COMMAND_CLASS_SENSOR_
MULTILEVEL_V5

Yes

Yes

COMMAND_CLASS_APPLICATION_
STATUS_V1

Yes

Yes

Yes

26   PRODUCT INFORMATION

PRODUCT INFO  

Heatit Z-Temp2

FEATURES

• 

Z-Wave thermostat for controlling external relays

• 

Internal room sensor

• 

Humidity sensor

• 

Proximity sensor to turn on the display

• 

SmartStart

• 

Automatic brightness control 

• 

Firmware updates (OTA)

• 

Weekly program/setback via gateway 

• 

5 associations 

• 

Lock mode/child lock

• 

Supports encryption modes S0, S2 Authenticated Class,  

S2 Unauthenticated Class 

This product is a security-enabled Z-Wave Plus product with
encryption. The product must be used with a security-enabled
Z-Wave Controller in order to fully utilize the product.

TECHNICAL DATA

Protocol 

Z-Wave

Chip 

Z-Wave 700 chip

Rated voltage 

3 x AA batteries (1,5V)

Ambient temperature 

5°C to 40°C

Humidity 

Max. 85% RH

Range RF 

Min. 40 meters 

Hysteresis  

0,3°C to 3,0°C (default 0,5°C)

IP Code 

IP 21

Approvals 

Z-Wave Plus V2, CE,  

RED 2014/53/EU, ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-3 

V2.1.1 (2019-03), ETSI EN 300 220-1  V3.1.1 (2017-02), ETSI  EN 300 220-2 

V3.2.1 (2018-06), EN 62479:2010, EN 62368-1:2014+A11:2017, RoHS 

2011/65/EU  

MAINTENANCE

The device is maintenance-free, but must never be covered.

ART. NO.

PRODUCT

COLOR

FREQUENCY

45 126 66

Heatit Z-Temp2 thermostat  Battery

White RAL 9003

EU 868,4MHz

45 126 67

Heatit Z-Temp2 thermostat  Battery

Black RAL 9011

EU 868,4MHz

99 306 10 

Heatit Z-Temp2 thermostat  Battery

White RAL 9003

RU 869,0MHz

99 306 68

Heatit Z-Temp2 thermostat  Battery

White RAL 9003

AUS 921,4MHz

Heatit Controls AB   l   Läkarvägen 4, 454 31 BRASTAD, SWEDEN 
Phone: +47 61 18 77 77    l   [email protected] – 

www.heatit.com

Heatit Controls AB can not be held liable for  

typographical errors, other errors or omittances in 

our information. Product specifications may change 

without further notice. 

All electrical installations must be carried out by a 

licensed electrician. The product must be installed 

in accordance with national building codes and our 

installers manual.

USE CASE

SENSOR TYPE

SIZE

SCALE

PRECISION 

Sends tempe-
rature report 
from internal 
sensor

Temperatu-
re(version 1) 
= 0x01

2Byte = 0x02

Celsius (°C) 
= 0x00

1 decimal 
= 0x01

Sends relative 
humidity 
report from 
internal sensor

Relative humi-
dity (version 2) 
= 0x05

2Byte = 0x02

Percentage 
value (%) 
=0x00

1 decimal 
= 0x01

Notification Command Class

When the device is turned back on after a power outage (insearted 

fresh batteries), the device sends a notification command to indicate 

that the device is back in idle state. The Device will also send a humidity  

report and temperature report when powered back on.

EVENT

TYPE

EVENT

LENGTH

Power On (OxFF)

Power maneg-
ment (0x08)

Power has been 
applied (0x01)

0x00