6. ADD/REMOVE
There are two ways to add your devices in a Z-Wave network.
6.1.
Method 1: standard (manual)
Please refer to your primary controller/gateway manual on how to
enter add/remove mode. The device can only be added or removed from
the network if the primary controller is in add/remove mode.
When the primary controller/gateway is set to add/remove mode press
the link button on the thermostat 3 times in a rapid sequence.
6.2.
Method 2: SmartStart (automatic)
Please refer to your primary controller/gateway to see if SmartStart is
supported by the controller. SmartStart enabled products can be added
into a Z-Wave network by scanning the Z-Wave QR-Code present on the
product with a controller providing SmartStart inclusion. No further action
is required and the SmartStart product will be added automatically within
10 minutes of being switched on in the network vicinity.
Enter SmartStart modus from your primary controller.
With the batteries for the devices taken out of the device. Scan the QR-
code on back of the device, then follow the gateway instructions.
If the device already belongs to a network, follow the removing process
before adding it in your network. Otherwise, the adding of this device will
fail. When the device is removed from the network,
the device will revert to factory settings.
7. FACTORY RESET
By pressing and holding the link button for 20 seconds, the thermostat
will perform a complete factory reset. rES will be displayed.
NB!
Please use this procedure only when the primary controller/
gateway is missing or otherwise inoperable.
8.
8. COMPABILITY / PRINCIPLES FOR REGULATION
COMPABILITY / PRINCIPLES FOR REGULATION
Water based heating
The thermostat uses temperature readings retrieved from the internal
sensor. Heatit Z-Temp2 is designed to work together with water based
heating solutions. Heatit recommends using Heatit Z-Temp2 together
with Heatit Z-Water. These two products allow for an advanced water
based heating solution by using a Z-Wave enabled controller. This
is a “wire-free” solution which save both time and money. All the
communication between Heatit Z-Temp2 and the controlled device is
wireless. The range can be extended using Heatit Z-Repeater or any other
device that supports routing. This makes our water based solutions a
good addition to your existing or new home automation system.
Electrical heating
Heatit Z-Temp2 could also be used in situations where a traditional
electrical thermostat is not suited. The battery-operated thermostat can
be used together with Heatit Z-Relay or any other relay device installed
in a remote location. Rehabilitation could be done using this solution to
avoid unnecessary wiring.
9. INFORMATION SHOWN IN DISPLAY
The thermostat benefits from two screens.
The main screen
The main screen displays measured temperature readout or relative
humidity. You can switch between the humidity and measured
temperature by pressing the center button while display is active.
The temperature and humidity can be calibrated using parameter
4 and 5 respectively. When childlock is active, there will displayed
a lock icon adjacent to the Celsius icon.
Secondary screen
This screen displays the setpoint temperature when the thermostat is in
heating mode. When the thermostat mode is turned OFF, the thermostat
will not use this display. To turn ON or OFF the thermostat you need to
hold center button for 10 seconds, or use Z-Wave command Basic or
Thermostat mode.
Connecting to an external relay
After the device is added to your Z-Wave gateway you will need to link
the thermostat to the device that is going to control the heating. This
is done by using association groups from the thermostat’s root device
(EP0) with Group 3 (ON/OFF Control) towards your actuator device (using
Multichannel or Single channel, based on the controlled device type.
*To set associations in your primary controller/gateway, please refer to
your primary controller/Z-Wave gateway for more information.
10. HYSTERESIS (DIF)
You can make changes to the hysteresis in the thermostat via the
parameter. This means that you can changes the hysteresis from