6.  ADD/REMOVE

There are two ways to add your devices in a Z-Wave network. 

6.1. 

Method 1: standard (manual)

Please refer to your primary controller/gateway manual on how to

enter add/remove mode. The device can only be added or removed from 

the network if the primary controller is in add/remove mode. 

When the primary controller/gateway is set to add/remove mode press 

the link button on the thermostat 3 times in a rapid sequence.

6.2. 

Method 2: SmartStart (automatic)

Please refer to your primary controller/gateway to see if SmartStart is 

supported by the controller. SmartStart enabled products can be added 

into a Z-Wave network by scanning the Z-Wave QR-Code present on the 

product with a controller providing SmartStart inclusion. No further action 

is required and the SmartStart product will be added automatically within 

10 minutes of being switched on in the network vicinity.

Enter SmartStart modus from your primary controller.

With the batteries for the devices taken out of the device. Scan the QR-

code on back of the device, then follow the gateway instructions.

If the device already belongs to a network, follow the removing process 

before adding it in your network. Otherwise, the adding of this device will 

fail. When the device is removed from the network,  

the device will revert to factory settings.

7.  FACTORY RESET 

By pressing and holding the link button for 20 seconds, the thermostat 

will perform a complete factory reset. rES will be displayed.

NB!

 Please use this procedure only when the primary controller/ 

gateway is missing or otherwise inoperable.

8. 

8.  COMPABILITY / PRINCIPLES FOR REGULATION

COMPABILITY / PRINCIPLES FOR REGULATION

Water based heating

The thermostat uses temperature readings retrieved from the internal 

sensor. Heatit Z-Temp2 is designed to work together with water based 

heating solutions. Heatit recommends using Heatit Z-Temp2 together 

with Heatit Z-Water. These two products allow for an advanced water 

based heating solution by using a Z-Wave enabled controller. This 

is a “wire-free” solution which save both time and money. All the 

communication between Heatit Z-Temp2 and the controlled device is 

wireless. The range can be extended using Heatit Z-Repeater or any other 

device that supports routing. This makes our water based solutions a 

good addition to your existing or new home automation system.

Electrical heating

Heatit Z-Temp2 could also be used in situations where a traditional 

electrical thermostat is not suited. The battery-operated thermostat can 

be used together with Heatit Z-Relay or any other relay device installed 

in a remote location. Rehabilitation could be done using this solution to 

avoid unnecessary wiring. 

9.  INFORMATION SHOWN IN DISPLAY

The thermostat benefits from two screens. 

The main screen

The main screen displays measured temperature readout or relative 

humidity. You can switch between the humidity and measured 

temperature by pressing the center button while display is active.  

The temperature and humidity can be calibrated using parameter  

4 and 5 respectively. When childlock is active, there will displayed  

a lock icon adjacent to the Celsius icon.

Secondary screen

This screen displays the setpoint temperature when the thermostat is in 

heating mode. When the thermostat mode is turned OFF, the thermostat 

will not use this display. To turn ON or OFF the thermostat you need to 

hold center button for 10 seconds, or use Z-Wave command Basic or 

Thermostat mode. 

Connecting to an external relay

After the device is added to your Z-Wave gateway you will need to link 

the thermostat to the device that is going to control the heating. This 

is done by using association groups from the thermostat’s root device 

(EP0) with Group 3 (ON/OFF Control) towards your actuator device (using 

Multichannel or Single channel, based on the controlled device type.

*To set associations in your primary controller/gateway, please refer to 

your primary controller/Z-Wave gateway for more information.

10. HYSTERESIS (DIF)

You can make changes to the hysteresis in the thermostat via the 

parameter. This means that you can changes the hysteresis from 

0,3°C up to max 3,0°C. Default is 0,5°C.