Parameter 3,
Parameter Size 2.
Humidity delta value
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0
0
0
0
Reporting tempe-
rature based on
change is disabled
5 to 50
5 to 50%
(Default 10, 10%)
Parameter 4,
Parameter Size 2.
Temperature offset settings
Calibrate the internal sensor.
NB!
To set negative values; 65 535 – desired value + 1.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
-100 to 100
0
0
0
-100 to 100°C
(Default 0, 0°C)
Parameter 5,
Parameter Size 2.
Humidity offset settings
Offsets the measured relative humidity.
NB!
To set negative values; 65 535 – desired value + 1.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
-100 to 100
0
0
0
-10 to 10%
(Default 0, 0%)
Parameter 6,
Parameter Size 2.
Proximity sensor retrigger interval
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
2 to 270
0
0
0
2 to 270 seconds
(Default 10, 10
seconds
)
Parameter 7,
Parameter Size 2.
Proximity sensor Enable / Disable
Choose if proximity sensor is used or not.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0
0
0
0
Disable
1
Enable (Default)
Parameter 8,
Parameter Size 2.
LED maximum brightness
Adjust the backlight of LCD display.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0 to 99
0
0
0
0 to 99%
(Default 50, 50%)
Parameter 9,
Parameter Size 2.
LED turned on before timeout
Adjust the time from proximity sensor / display touched until display goes to sleep.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
3 to 300
0
0
0
3 to 300 seconds
(Default 3, 3 seconds)
Parameter 10,
Parameter Size 2.
Temperature Control Hysteresis
Adjust the delta values for the thermostat to turn on off heating.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
3 to 30
0
0
0
0.3 to 3°C
(Default 5, 0,5°C)
Parameter 11,
Parameter Size 2.
Minimum Temperature Limit
Set the mimum temperature limit.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
50 to 400
0
0
0
5 to 40°C
(Default 50, 5°C)
Parameter 12,
Parameter Size 2.
Maximum Temperature Limit
Set the maximum temperature limit.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
50 to 400
0
0
0
5 to 40°C
(Default 400, 40°C)
Parameter 13,
Parameter Size 2.
External Relay & Operating State update interval
Set time on how often the devices sends Binary Switch Set and thermostat mode to gateway.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0
0
0
0
Sends only when
changed (Default)
1 to 240
1 to 240 m
When changed
Parameter 14,
Parameter Size 2.
Report when presence is detected
Decides if the thermostat sends temperature when presence is detected.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0
0
0
0
Do not report to
gateway when
presence is detected,
only at interval.
(Default)
1
Send temperature
report to gateway
when presence is
detected.
Parameter 15,
Parameter Size 2.
Inverted output
Decides if the relay output should be inverted.
VALUE
READ-
ONLY
ADVANCED
ALTERING
CAPABILITIES
DESCRIPTION
0
0
0
0
Disabled (Default)
1
Enable
19. OPERATING THE DEVICE
No Multi Channel support/ Multichannel support:
Besides the mandatory command classes, Heatit Z-Temp2 has
support for following command classes:
Thermostat Mode
It is possible to change the operating mode of the thermostat by sending
a Thermostat Mode Set command.
Uses the following values;
0x00 = OFF (Thermostat regulation is deactivated)
0x01 = Heating Mode (Thermostat regulation is active)
Thermostat Setpoint Command Class
When a Thermostat Setpoint Set command is received by the root device,
it sets the actual setpoint for heating mode.
Basic Command Class
A Basic Set to the root endpoint will change the thermostat mode.
Uses the following values;
0x00 = OFF (Thermostat regulation is deactivated)
0x01 = Heating Mode (Thermostat regulation is active)
Multilevel Sensor Report
The device sends Multilevel Sensor Reports to indicate measured
temperature and relative humidity. The device will send a humidity and
temperature report when powered on after a power loss.