![Heatilator Wood Burning Fireplace EL36 Series Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/heatilator/wood-burning-fireplace-el36-series/wood-burning-fireplace-el36-series_owners-manual_2117312031.webp)
Heatilator • EL36/EL42 • 4044-132 Rev P • 02/07
31
E. Sidewalls/Surrounds
Adjacent combustible side walls must be located a minimum
of 12 in. (305 mm) from the
fi
replace opening. If you are us-
ing a decorative surround constructed of combustible ma-
terial, it must be located within the shaded area de
fi
ned in
Figure 8.7. Short stub walls are also acceptable if they are
contained within the shaded area.
9-3/4 in.
(248 mm)
14-3/8 in.
(365 mm)
12 in.
(305 mm)
4 in.
(102 mm)
Brick
Front
Flush
Front
12 in.
(305 mm)
A
B
50 deg.
39 deg.
Figure 8.7 Sidewalls/Surrounds
D. Mantel
A combustible mantel may be positioned no lower than
12 in. (305 mm) above the top of the
fi
replace opening. The
combustible mantel may have a maximum depth of 12 in.
(305 mm) Combustible trim pieces that project no more
than 1-1/2 in. (38 mm) from the face of the
fi
replace can be
placed no closer than 6 in. (152 mm) from the top of the
fi
re-
place opening. See Figure 8.6. Combustible trim must not
cover the black metal surfaces of the
fi
replace. This mantel
clearance is in accordance with
Section 7-3.3.3 of ANSI/
NFPA211
.
12 in. (305 mm)
min.
12 in. (305 mm)
max.
Top of
Fireplace
Opening
Mantel
1-1/2 in. (38 mm) max.
6 in. (152 mm) min.
Header
Standoff
Figure 8.6 Mantel Speci
fi
cations
Model #
A
Fireplace
Opening
B
Outside
Dimensions
EL36
in.
36
41
mm
914
1041
EL42
in.
42
47
mm
1067
1194
• Combustible
Materials
Materials made of or surfaced with wood, compressed
paper, plant
fi
bers, plastics, or other material that can ig-
nite and burn, whether
fl
ame proofed or not, or whether
plastered or unplastered shall be considered combus-
tible materials.
• Non-Combustible Sealant Material
Sealants which will not ignite and burn: Rutland, Inc. Fire-
place Mortar #63, Rutland 76R, Nu
fl
ex 304, GERTV106
or GE RTV116 (or equivalent).
F. Glass Doors
This
fi
replace has been tested and listed for use with doors
as speci
fi
ed in Section 12.B. Fireplace Components. Please
refer to the manual packed with each set of doors for instal-
lation instructions.
Fire Risk
Finish all edges and fronts to clearances and
speci
fi
cations.
• Metal
fi
replace front may be covered with
non-combustible material only.
• Do NOT overlap combustible materials onto
fi
replace front.
• Install combustible materials up to speci
fi
ed
clearances on top front and side edges.
• Seal joints between the
fi
nished wall and
fi
replace top and sides using only a 300° F
minimum sealant.
WARNING