NOVI30 AND NOVI35
Roof Pitch .......... H (Min.) Ft.
Flat to 6/12 .......................... 1.0
6/12 to 7/12 ...................... 1.25
Over 7/12 to 8/12 ............... 1.5
Over 8/12 to 9/12 ............... 2.0
Over 9/12 to 10/12 ............. 2.5
Over 10/12 to 11/12 ......... 3.25
Over 11/12 to 12/12 ........... 4.0
Over 12/12 to 14/12 ........... 5.0
Over 14/12 to 16/12 ........... 6.0
Over 16/12 to 18/12 ........... 7.0
Over 18/12 to 20/12 ........... 7.5
Over 20/12 to 21/12 ........... 8.0
Table 1
Minimum Termination Height
WARNING!
The exhaust pipe must only
be connected to the exhaust
starting collar of the
appliance and the center
collar of the termination cap
adapter.
The air inlet pipe must only be
connected to the air inlet
collar on the appliance and
either attached to the air inlet
collar of the termination cap
adapter or terminated in the
Figure 6 - Termination Height
Figure 5 - Air inlet
not connected to the adapter at the
top
Figure 4 - Typical Installation
Figure 7 - Multiple Chimney Terminations