Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Installation Manual • 2458-980 Rev. B • 8/17
12
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.6).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.6 Appliance Locations
A
B
C
D
E
F
B
F
B
E
D
A
Note:
Dimensions below refer to a framed wall on
which 1/2 inch wall sheathing has not been installed.
A
B
C
D
E
F
HEIR36
Inches
74-1/4
59-1/2
105
26-1/2
23-1/2
29-3/4
Millimeters
1886
1511
2667
673
597
756
HEIR42
Inches
78-9/16
65-9/16 111-1/16
28-5/8
23-1/2
32-13/16
Millimeters
1995
1665
2821
727
597
833
HEIR50
Inches
84-1/4
73-9/16 119-1/8
31-1/2
23-1/2
36-13/16
Millimeters
2140
1868
3026
800
597
935