Heatilator • CI60 • 4013-031 Rev M • 10/06
9
3
3
Framing and Clearances
A. Selecting Fireplace Location
Several options are available to you when choosing a loca-
tion for your
¿
replace. This
¿
replace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 3.1.
A
60-1/8 in.
(1527 mm)
42-1/2 in.
(1080 mm)
45-1/2 in.
(1156 mm)
85 in. (2159 mm)
5/8 in. (16 mm)
all configurations
1 in. (25 mm) min. distance
from fireplace to
combustible materials.
Note:
In an exterior chase
or projecting into a
garage
Across a
corner
As a room
divider
Along a wall
28 in.
(711 mm)
A
28 in.
(711 mm)
28 in. (711 mm)
A
19-3/8 in.
(492 mm)
Note:
In addition to these
framing dimensions,
also reference the
following sections:
• Clearances (Section
3.B.)
• Mantel Projections
(Section 8.C)
• Fireplace Dimensions
(Section 12.A.)
48 in.
(1219 mm)
12 in.
(305 mm)
Figure 3.1
Fireplace Locations
Fire Risk
Provide adequate clearances.• Around air
openings
• To
combustibles
• For service access.
Locate
¿
replace away from traf
¿
c areas.
WARNING
Note:
•
Illustrations and photos re
À
ect typical installations
and are FOR DESIGN PURPOSES ONLY.
•
Illustrations/diagrams are not drawn to scale.
•
Actual installation/appearance may vary due to
individual design preference.
•
Hearth & Home Technologies reserves the right to
alter its products.
Locating the
¿
replace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of
considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the
¿
re-
place. Consideration should be given to these factors before
deciding on a location. See Sections 2 and 10.
CI60
A
With Outside
Air
in.
49-1/2
mm
1257
Without
Outside Air
in.
45-1/2
mm
1156