background image

Heatilator • CI60 • 4013-031 Rev M • 10/06

29

G. Grate

The factory installed integral grate must be used to hold the 
logs from falling out of an open 

¿

 replace and to allow air to 

pass between the burning logs. It is important to keep the 

¿

 re 

off the hearth and to allow the ashes to collect beneath the 

¿

 re, thereby forming a layer of additional heat protection.

H. Wood Fuel

Firewood

Your 

¿

 replace performance depends on the quality of the 

¿

 rewood you use. All seasoned wood, regardless of spe-

cies, contains about 8,000 BTU’s per pound, and hard-
woods have a greater density than soft woods. A piece 
of hardwood will contain about 60% more BTU’s than 
an equal size piece of soft wood. Firewood is commonly 
sold by the cord (128 cu. ft.).  A cord of seasoned oak 
(hardwood) would contain about 60% more potential en-
ergy than a cord of seasoned pine (soft wood).

Examples of soft wood trees are Douglas 

¿

 r, pine, spruce, 

and cedar, poplar, aspen and alder. Soft woods require 
less time to dry, burn faster and are easier to ignite than 
hardwoods.

Examples of hardwood trees are oak, maple, apple, and 
birch. Hardwoods require more time to season, burn 
slower and are usually harder to ignite than soft woods.

The best wood fuel is a combination of soft wood and 
hardwood. Start the 

¿

 re with soft wood; the 

¿

 re will give 

off quick heat to bring the 

¿

 replace up to operating tem-

perature, and then the hardwood can be added for slow, 
even heat and longer burn time.

Moisture

Regardless of which species of wood you burn, the single 
most important factor that effects the way your 

¿

 replace 

operates is the amount of moisture in the wood. The ma-
jority of the problems 

¿

 replace owners experience are 

caused by trying to burn wet, unseasoned wood.

Freshly cut wood can be as much water as it is wood, 
having a moisture content of around 50%. Imagine a 
wooden bucket that weighs about eight pounds. Fill it 
with a gallon of water, put it in the 

¿

 replace and try to burn 

it. This sounds ridiculous but that is exactly what you are 
doing if you burn unseasoned wood.

Fire Risk

  Use only factory installed integral grate.

May cause over

¿

 re.

WARNING

Seasoning

Seasoned 

¿

 rewood is nothing more than wood that is 

cut to size, split and air dried to a moisture content of 
around 20%. The time it takes to season wood varies 
from around nine months for soft woods to as long as 
eighteen months for hardwoods. The key to seasoning 
wood is to be sure it has been split, exposing the wet 
interior and increasing the surface area of each piece. A 
tree that was cut down a year ago and not split is likely 
to have almost as high a moisture content now as it did 
when it was cut.

The following guideline will ensure properly seasoned 
wood:

•  Stack the wood to allow air to circulate freely  around 

and through the woodpile.

•  Elevate the woodpile off the ground to allow air 

circulation underneath.

•  The smaller the pieces, the faster the drying process. 

Any piece over 6 in. (152 mm) in diameter should be 
split.

•  Cover the top of the woodpile for protection from 

rain and snow. Avoid covering the sides and ends 
completely. Doing so may trap moisture from the 
ground and impede air circulation.

The problems with burning wet, unseasoned wood are 
twofold: First, you will receive less heat output from wet 
wood because it requires energy in the form of heat to 
evaporate the water trapped inside. This is wasted ener-
gy that should be used for heating your home. Secondly, 
this moisture evaporates in the form of steam which has 
a cooling effect in your 

¿

 replace and chimney system. 

When combined with tar and other organic vapors from 
burning wood it will form creosote which condenses in 
the relatively cool 

¿

 replace and chimney.

Fire Risk

  Do NOT burn wet or green wood.

  Store wood in dry location.

•  Stack wood so both ends are exposed to 

air.

W e t ,   u n s e a s o n e d   w o o d   c a n   c a u s e 
accumulation of creosote.

WARNING

Fire Risk

Do NOT store wood:
•  Closer than required clearances to 

combustibles to 

¿

 replace.

•  Within space required for loading or ash 

removal.

WARNING

Содержание Heatilator CI60

Страница 1: ...TOUCH SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT WARNING Keep children away CAREFULLY SUPERVISE children in same room as replace Alert children and adults to hazards of high temperatures Ke...

Страница 2: ...n Location The model information regarding your speci c replace can be found on the rating plate located on the smoke shield of the replace Congratulations FIREPLACE NO MODEL NO MODEL NO MFG DATE WARN...

Страница 3: ...Chimney 20 6 Complete the Enclosure 21 A Chimney Termination 21 B Chase Top 22 C Install the Termination Cap 22 7 Accessories 23 A Gas Log Lighter Provisions 23 8 Finishing 24 A Hearth Extension 24 B...

Страница 4: ...a decorative replace It should not be factored as a primary heat source in residential heating calculations Improper installation adjustment alteration service or maintenance can cause injury or prope...

Страница 5: ...diate vicinity of the replace Avoid installing the replace near doors walkways or small isolated spaces Recessed lighting should be a sealed can design attic hatches weather stripped or sealed attic m...

Страница 6: ...e the highest part of the roof This minimizes the effects of wind turbulence Be located away from trees adjacent structures uneven roof lines and other obstructions Offsets can restrict draft so their...

Страница 7: ...ng and trim Hearth extension Factory built fireplace Protective metal hearth strip s Outside combustion air Combustible framing header on top of V shaped standoffs spacers Chimney system Ceiling fires...

Страница 8: ...d or rust may cause odors CAUTION E Inspect Fireplace and Components Carefully remove the replace and components from the packaging The vent system components and doors are shipped in separate package...

Страница 9: ...ctions Section 8 C Fireplace Dimensions Section 12 A 48 in 1219 mm 12 in 305 mm Figure 3 1 Fireplace Locations Fire Risk Provide adequate clearances Around air openings To combustibles For service acc...

Страница 10: ...51 mm minimum clearance to header Ceiling Firestop Offset Return with hanger straps Storm Collar Roof Flashing 0 in to level of standoffs Figure 3 2 Clearances to Combustible Materials Note Chimney ai...

Страница 11: ...ustible materials are used All re quired clearances to combustibles around the replace must be adhered to See Figure 3 2 Any framing across the top of the replace must be above the level of the top st...

Страница 12: ...himney Ceiling Firestop Tabs False Ceiling False Ceiling Insulation Insulation Figure 3 5 Chase Assembly F Chimney Requirements When planning your replace location the chimney construc tion and necess...

Страница 13: ...to minimize the effects of negative pressure within the structure We recommend you utilize the shortest duct run to optimize the performance of the outside air kit Cold air ow can be minimized by putt...

Страница 14: ...e YES NO NO NO NO Use only duct materials specified by manufacturer preferably with short run or mainly straight duct except small dip for cold air trap which will help prevent flow of cold air Factor...

Страница 15: ...tform must be protected with a protective metal hearth strip as shown in Figure 4 4 Raised Platform Floor 2 in 51 mm 1 in 25 mm min overlap 2 in 51 mm Top piece must overlap bottom piece Figure 4 4 Pr...

Страница 16: ...upport for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustibles as specified Offsets returns may not exceed 30 from vertical Lock chimney s...

Страница 17: ...fset return 90 ft 27 4 m max height 6 ft 1 8 m max unsupported chimney above roof 71 3 4 in 1822 mm Effective Height bottom of fireplace to top of starter collar Figure 5 2 Chimney Requirements Table...

Страница 18: ...se of the replace to the top of the starter collar See Dimensions in Section 12 Table 5 2 A B 1 1 4 in 32 mm OVERLAP Figure 5 3 Chimney Offset Return Example Your A dimension from Figure 5 3 is 14 1 2...

Страница 19: ...rovide support for the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the replace or at any chimney joint Note Inner flue and outer liner...

Страница 20: ...with the screws provided outer only using the predrilled holes To prevent gravity from pulling the chimney sections apart the returns and the chimney stabilizers have hanger straps for securing these...

Страница 21: ...plugged by snow or other material Must terminate at least 3 ft 914 mm above the roof and at least 2 ft 61 mm above any portion of the roof within 10 ft 3 05 m Must be located away from trees or other...

Страница 22: ...coping Termination Cap the uppermost chimney section must be below the top of the chase top but not more than 14 1 2 in 368 mm below the top of the chase top Minimum overlap of chimney and termination...

Страница 23: ...2 in 38 mm air space around the pipe for 4 in 102 mm beyond the replace See Figure 7 1 Firebox Repack Insulation Knockout Combustible Materials Maintain air clearance to combustibles Gas Line Combust...

Страница 24: ...r the factory available hearth ex tensions see Figure 8 3 and calculate insulation alterna tives as per Table 8 1 and the following formulas Thermal conductivity per inch thickness k k BTU inch foot2...

Страница 25: ...nsion Micore Floor Note Maximum height from floor under fireplace to top of finished hearth extension is 7 5 8 in 195 mm Figure 8 5 Flush Hearth Extension 30 in 762 mm min 12 in 305 mm Min 12 in 305 m...

Страница 26: ...temperature rise and re hazard Finishing materials must not interfere with Air ow through grilles or louvers Operation of louvers or doors Access for service WARNING C Mantel A combustible mantel may...

Страница 27: ...llation and operation of the replace Make certain that installation and operation of the replace system is in accordance with these instructions It is extremely important that the re be supervised whe...

Страница 28: ...with tightly sealed doors and windows are relatively air tight In this case an outside air source must be made available to feed combustion air from outside the home An outside air control handle allo...

Страница 29: ...t it in the replace and try to burn it This sounds ridiculous but that is exactly what you are doing if you burn unseasoned wood Fire Risk Use only factory installed integral grate May cause over re W...

Страница 30: ...ders to be burned from the replace and the refractory and paint to cure You may notice an industrial odor the rst few res This is considered normal Note When rst lighting your replace it may be necess...

Страница 31: ...ight sealing construction of the structure or mechan ical exhausting devices which will create a negative air pres sure within the structure where the replace is located A Understanding Vent Problems...

Страница 32: ...chimney Downdraft from chimney temperature or from negative house pressure Does the kindling wood not ignite Condition amount arrangement of kindling and fuel Use more drier well spaced kindling and f...

Страница 33: ...Fire too close to front Build re farther back Do not use exhaust fans during startup and or check for need for balanced air make up system Competition with exhaust devices Diagnostic Questions Possib...

Страница 34: ...Remove screws and lift top cover Figure 11 1 Chimney Termination Cap Cleaning Fire Risk Disposal of ashes Ashes should be placed in metal container with tight tting lid Do not place metal container o...

Страница 35: ...properly engaged and the chimney is properly secured A chimney re can permanently damage your chimney sys tem Failure to replace damaged components and make proper repairs creates risk of re Inspect...

Страница 36: ...m 43 1 8 in 1095 mm 59 1 4 in 1505 mm 7 5 8 in 194 mm 36 in 914 mm 71 3 4 in 1822 mm effective height Gas Knockout 8 5 8 in 219 mm 9 5 8 in 244 mm 9 1 2 in 241 mm 9 1 4 in 235 mm Outside Air Gas Knock...

Страница 37: ...CI60CT Fireplace with integral grate outside air kit SLA10 hearth protection strips and colored traditional brick pattern refractory CI60H Fireplace with integral grate outside air kit SLA10 hearth pr...

Страница 38: ...in 330 mm Inside Diameter 10 in 254 mm 20 3 4 in 527 mm Catalog Description CAK5A Chimney Air Kit required in Canada ID4 Insulated Duct Outside Air UD4 Uninsulated Duct Outside Air SL406 Chimney Sect...

Страница 39: ...n 610 mm 17 in 432 mm AS10 Straight Attic Insulation Shield 2 in 51 mm 13 in 330 mm JB577 Chimney Joint Band 13 in 330 mm CB576 Chimney Joint Band 15 1 4 in 387 mm 28 in 711 mm 39 7 8 in 1013 mm RF571...

Страница 40: ...ation Cap 72 in 1829 mm 36 in 914 mm 2 in 51 mm 13 3 8 in 340 mm CT56 Chase Top A B C D Decorative Shroud LDS33 LDS46 15 3 4 in 400 mm 32 3 8 in 822 mm 34 3 8 in 873 mm 14 3 4 in 375 mm 23 in 584 mm 2...

Страница 41: ...mm with Radiation Shield 28 x 30 in 711 x 762 mm 34 x 34 in 864 x 864 mm with Radiation Shield 28 x 30 in 711 x 762 mm with Radiation Shield or 34 x 34 in 864 x 864 mm Minimum Height N A 28 1 4 in 718...

Страница 42: ...Heatilator CI60 4013 031 Rev M 10 06 44 This page intentionally left blank...

Страница 43: ...Heatilator CI60 4013 031 Rev M 10 06 45 This page intentionally left blank...

Страница 44: ...Heatilator CI60 4013 031 Rev M 10 06 46 This page intentionally left blank...

Страница 45: ...ling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those speci ed in the Operating Instructions 6 installation or use of components not supplied with th...

Страница 46: ...162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019...

Отзывы: