
71
Heatilator • CRAVE4836-C/ST-C, CRAVE6048-C/ST-C, CRAVE7260-C/ST-C, CRAVE8472-C/ST-C Installation Manual • 2601-980 Rev. N • 11/21
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specified in
this manual. Overlapping materials could ignite.
1. Follow instructions provided with decorative barrier
front for installation.
The non-combustible finishing material, 0-1 inch thick,
should be installed up to the fireplace opening on the top
and sides.
Use the factory-installed top finishing guard to ensure the
finishing material does not extend into the fireplace open
-
ing.
Non-combustible finishing material should be installed
on the bottom up to the bottom finishing template. See
Figure 10.9. Do not cover the eight rectangular holes on
the bottom access panel. See Figure 10.10 for minimum
finished opening dimensions.
WARNING! Risk of Fire! DO NOT
cover rectangular
holes on bottom access panel when installing overlap
fronts.
Figure 10.9 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method (Four Square/Illusion)
WARNING! Risk of Fire! DO NOT
apply finishing mate-
rial beyond the top finishing guard and the bottom finish-
ing template. Appliance will overheat if finishing material
extends into appliance opening.
NOTICE:
Decorative barrier front will not fit properly if
finishing material is applied beyond the finishing guard.
Four Square and Illusion Decorative Barrier Front
BOTTOM PANEL
BOTTOM FINISHING TEMPLATE
= RECTANGULAR ACCESS HOLES
DO NOT COVER
Non-Combustible Finish Materials
Overlap Fit (0-1 Inch Thick Finishing Material Only)
Decorative Barrier Front
Finishing Method
Material Thickness
Trim Ring
Four Square/Illusion
Overlap Fit
0-1 inch
Not included
NOTICE:
If one inch maximum finishing material thickness
is exceeded, the decorative barrier front will not fit. This
one inch maximum not only includes the decorative finish
materials (marble, tile, slate, etc) but also the thin set, lath
and adhesive used to attach the decorative finish material
.