Hearth & Home Technologies • CNXT70PLUS • 4034-105 Rev C • 09/05
15
HRV200PLUS Control Wiring
The CNXT70PLUS is designed to operate as a system
with the HRV200PLUS. Six low-voltage wires are required
to electrically connect the two appliances. Common 24
gauge solid conductor thermostat wire, or equivalent may
be used.
EMBER LIGHTS
OFF/ON
HI/EMBER
FIRE
T14
T13
T12
T11
T10
T9
P1
REM
REM
LOW
P2
LO
HI
12V
C1
C2
COM
R1
K3
K2
K1
T8
T7
T6
T5
T4
T3
T2
T1
T16
T15
IPI
SOLENOID
PRESS. SW
R1
LED1
LINE
NEU
EMBER
Not Used
Install Jumper
between R2 & 12V.
Figure 8.2
CNXT70PLUS & HRV200PLUS Boards Wired Together
The connections are illustrated in Figure 8.2. A short
jumper wire is required to be fi eld installed between R2
and 12V on the HRV200PLUS control board.