2. Standing Pilot Ignition Appliances

FOR YOUR SAFETY READ BEFORE LIGHTING THE STANDING PILOT

A. This  appliance  has  a  manual  ignition  device  that

lights the pilot. When lighting the pilot, follow these

instructions exactly.

B. BEFORE LIGHTING smell all around the appliance

area  for  gas.  Be  sure  to  smell  next  to  the  floor

because some gas is heavier than air and will settle

on the floor.

WHAT TO DO IF YOU SMELL GAS

•

Do not try to light any appliance.

•

Do  not  touch  any  electric  switch;  do  not

use any phone in your building.

•

Immediately call your gas supplier from a

neighbor’s  phone.  Follow  the  supplier’s

instructions.

•

If you cannot reach your gas supplier, call

the fire department.

C. Use only your hand to push in or turn knob. Never

use  tools.  If  the  knob  will  not  push  in  or  turn  by

hand, don’t try to repair it; call a qualified service

technician.  Force  or  attempted  repair  may  result

in a fire or explosion.

D. Do  not  use  this  appliance  if  any  part  has  been

under  water.  Immediately  call  a  qualified  service

technician to inspect the appliance and to replace

any part of the control system and any gas control

which as been under water.

WARNING!

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal

injury or loss of life.

LIGHTING INSTRUCTIONS

STOP! Read the safety information above on this label!

1. Turn off wall switch.

2

. Open control access panel.

3

. Turn gas line to “CLOSED”. Wait 5 minutes to clear out

any gas. Then smell for gas, including near the floor. If

you smell gas, STOP! Follow “B” in the safety information

above on this label. If you don’t smell gas, go to the next

step.

4

. Turn gas line to “OPEN”.

5

. Turn pilot knob clockwise to “OFF”. Knob may have t o

be depressed to pass the “PILOT” position.

6

. Locate pilot assembly inside appliance.

7

. Locate red ignitor button.

8

. Turn pilot knob to “PILOT” and push in.

9. Continue to hold in pilot knob and push the red ignitor

button 12-15 times until small blue pilot flame appears.

10. Continue to hold in pilot knob for approximately one minute.

Pilot should remain lit. If pilot goes out, wait 5 minutes and

repeat Steps 4-9.

11

. Release and turn the knob counterclockwise to “ON”. To

light the main burner, turn the wall switch to “ON”. Do not

light by hand.

12. If the appliance will not operate, follow the instructions

“To Turn Off Gas To Appliance” and call your service

Note: 

To  light  main  burner,  turn  the  Wall  Switch  to

“ON”. Do not light by hand.

TO TURN OFF THE GAS TO THE APPLIANCE

1.

Turn off the wall switch.

2.

Open the control access panel.

3.

Turn the gas line to CLOSED position. Do not force.

4.

Close the  control access panel.

5

11

8

7

6

4

3

2

Содержание CALIBER DESIGNER B-VENT SERIES

Страница 1: ...or explosion may result causing property damage personal in jury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What...

Страница 2: ...dding materials etc It is imperative that the control compartment burners and circulating air passageways of the appliance be kept clean 4 This is a vented decorative gas appliance Do not burn wood or...

Страница 3: ...construction stage of the home If you desire to put an appliance in your basement we recommend that you consider a direct vent gas appliance Basements always have a significant negative air pressure...

Страница 4: ...f ANSI Z97 1 1984 and CPSC 16 CFR 1202 Safety Glazing Certification Council SGCC 1595 and 1597 Architectural Testing Inc Reports 02 31919 01 and 02 31917 01 This statement is in compliance with SPCS 1...

Страница 5: ...d n a t s h g u o r h t e e S e c n a i l p p a 6 3 L F B G e c n a i l p p a s a g l a r u t a n t o l i p g n i d n a t s a l u s n i n e P 6 3 R C B G s a g l a r u t a n t o l i p g n i d n a t s...

Страница 6: ...ble Materials 3 High Altitude Installation For U S installation appliances are tested and approved for elevations from 0 2000 feet When installing this appliance at an elevation above 2000 feet United...

Страница 7: ...ppliance Slide the appliance into position and level the appliance from side to side and front to back Shim with noncombustible material as necessary Secure the appliance by bending out the nailing fl...

Страница 8: ...ical Termination Vent Lengths 2 Firestop Spacer Vent Installation Frame an opening and install a firestop spacer whenever the vent penetrates a ceiling floor area as shown in Figure 6 Frame the openin...

Страница 9: ...ntilation is good If the flames and smoke are forced away from the draft hood this may indicate a ventilation blockage or down draft resulting in gas spillage into the home If this occurs turn off the...

Страница 10: ...Appendix F Note The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pres sures in excess of 1 2 psi 3 5...

Страница 11: ...plugged if the battery pack is used Note This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70...

Страница 12: ...the Romex connector feed the necessary length of wire through the connector and tighten the screws 3 Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the...

Страница 13: ...63 or equivalent A high temperature sealant 1 8 inch wide minimum must be used to close off gaps between the appliance and facing to prevent cold air leaks See Figure 14 4 Combustible Mantel A combust...

Страница 14: ...wool touches but does not cover the holes in the burner pan This will provide the glowing embers look See Figure 17 It is not necessary to use the entire bag Save the remainder for future use 10 Repl...

Страница 15: ...ely call your gas supplier from a neighbor s phone Follow the supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the manual shutoff val...

Страница 16: ...ly a fire or explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS STOP Read the safety information above on this label 1 Turn off wall switch 2 Open contr...

Страница 17: ...under water Immediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Before operating thi...

Страница 18: ...hrough burning the appliance open the control access panel grasp the handle and rotate to the CLOSED position Figure 19 Operating the AK14 Outside Air Kit s e u s s I s n o i t u l o S d n a s e s u a...

Страница 19: ...an adjustable air shutter Your air shutter is provided in the closed position for natural gas and in the open position for propane In the event soot is accumulating in your appliance the air shutter...

Страница 20: ...maining glass pieces with a shop vac DO NOT VACUUM IF PIECESAREHOT Replace glass with a Heatilator glass panel assembly only ordered through your local distributor Never use substitute material 6 Log...

Страница 21: ...Switch RC SMART HTL Remote Control RC ELEC HTL Remote Control Electronic Ignition RC BATT HTL Battery Operated Remote Control Standing Pilot RCT MLT HTL Multi Function Remote Control SMART STAT HTL R...

Страница 22: ...3 9 8 5 2 l e n a P s s e c c A l o r t n o C 4 1 6 1 6 2 y l b m e s s A n e e r c S t n o r F 5 9 5 6 7 2 d o o H e d i S 6 3 1 9 5 2 e c a F d n E r e w o L 7 8 5 1 6 2 y l b m e s s A s s a l G d...

Страница 23: ...4 Cleaning 20 Specifications 4 Grounding 11 H High Altitude Installation 6 High Temperature Sealant 13 Hood 13 I Input Rate 9 10 Intermittent Pilot Ignition 11 15 17 J Junction Box Installation 12 L...

Страница 24: ...quate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those spe...

Отзывы: