Heatilator CALIBER DESIGNER B-VENT SERIES Скачать руководство пользователя страница 11

01/04

11

CALIBER DESIGNER SERIES

4. Wiring

a. Intermittent Pilot Ignition

1)

This appliance requires a 110VAC supply to

the  appliance  junction  box  for  operation. A

wiring diagram is shown in Figure 12.

2)

This  appliance  is  equipped  with  an

intermittent pilot control valve which operates

on a 3V system.

3)

This appliance is supplied with a battery pack

and a 3VAC transformer, which requires the

installation of the supplied junction box. We

highly  recommend  that  the  junction  box  be

installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries

(not included). Batteries cannot be placed in

the  battery  pack  while  using  the  3VAC

transformer.  Conversely,  the  transformer

must be unplugged if the battery pack is used.

Note:

 

This appliance must be electrically wired and

grounded in accordance with local codes or, in the

absence of local codes, with 

National Electric Code

ANSI/NFPA 70-latest edition

 or the 

Canadian Elec-

tric Code, CSA C22.1

.

3. Gas Conversions

Natural  or  propane  gas  fuel  conversions  necessary

to meet the application need to be made by a qualified

technician  using  Hearth  &  Home  Technologies

specified  and  approved  parts.
In the event your appliance must be converted to

propane/standing pilot, use 

CKVP

;

natural gas/standing pilot, use 

CKVN

;

propane/intermittent pilot, use 

DCKVP

;

natural gas/intermittent pilot, use 

DCKVN

.

WARNING!

The gas control valve has been preset at the

factory. Altering settings may result in fire haz-

ard or bodily injury.

Figure 12

Intermittent Pilot Ignition Wiring Diagram

CAUTION:

Battery polarity must be correct or control mod-

ule damage will occur.

Содержание CALIBER DESIGNER B-VENT SERIES

Страница 1: ...or explosion may result causing property damage personal in jury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What...

Страница 2: ...dding materials etc It is imperative that the control compartment burners and circulating air passageways of the appliance be kept clean 4 This is a vented decorative gas appliance Do not burn wood or...

Страница 3: ...construction stage of the home If you desire to put an appliance in your basement we recommend that you consider a direct vent gas appliance Basements always have a significant negative air pressure...

Страница 4: ...f ANSI Z97 1 1984 and CPSC 16 CFR 1202 Safety Glazing Certification Council SGCC 1595 and 1597 Architectural Testing Inc Reports 02 31919 01 and 02 31917 01 This statement is in compliance with SPCS 1...

Страница 5: ...d n a t s h g u o r h t e e S e c n a i l p p a 6 3 L F B G e c n a i l p p a s a g l a r u t a n t o l i p g n i d n a t s a l u s n i n e P 6 3 R C B G s a g l a r u t a n t o l i p g n i d n a t s...

Страница 6: ...ble Materials 3 High Altitude Installation For U S installation appliances are tested and approved for elevations from 0 2000 feet When installing this appliance at an elevation above 2000 feet United...

Страница 7: ...ppliance Slide the appliance into position and level the appliance from side to side and front to back Shim with noncombustible material as necessary Secure the appliance by bending out the nailing fl...

Страница 8: ...ical Termination Vent Lengths 2 Firestop Spacer Vent Installation Frame an opening and install a firestop spacer whenever the vent penetrates a ceiling floor area as shown in Figure 6 Frame the openin...

Страница 9: ...ntilation is good If the flames and smoke are forced away from the draft hood this may indicate a ventilation blockage or down draft resulting in gas spillage into the home If this occurs turn off the...

Страница 10: ...Appendix F Note The appliance and its manual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pres sures in excess of 1 2 psi 3 5...

Страница 11: ...plugged if the battery pack is used Note This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70...

Страница 12: ...the Romex connector feed the necessary length of wire through the connector and tighten the screws 3 Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the...

Страница 13: ...63 or equivalent A high temperature sealant 1 8 inch wide minimum must be used to close off gaps between the appliance and facing to prevent cold air leaks See Figure 14 4 Combustible Mantel A combust...

Страница 14: ...wool touches but does not cover the holes in the burner pan This will provide the glowing embers look See Figure 17 It is not necessary to use the entire bag Save the remainder for future use 10 Repl...

Страница 15: ...ely call your gas supplier from a neighbor s phone Follow the supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the manual shutoff val...

Страница 16: ...ly a fire or explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS STOP Read the safety information above on this label 1 Turn off wall switch 2 Open contr...

Страница 17: ...under water Immediately call a qualified service techni cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water Before operating thi...

Страница 18: ...hrough burning the appliance open the control access panel grasp the handle and rotate to the CLOSED position Figure 19 Operating the AK14 Outside Air Kit s e u s s I s n o i t u l o S d n a s e s u a...

Страница 19: ...an adjustable air shutter Your air shutter is provided in the closed position for natural gas and in the open position for propane In the event soot is accumulating in your appliance the air shutter...

Страница 20: ...maining glass pieces with a shop vac DO NOT VACUUM IF PIECESAREHOT Replace glass with a Heatilator glass panel assembly only ordered through your local distributor Never use substitute material 6 Log...

Страница 21: ...Switch RC SMART HTL Remote Control RC ELEC HTL Remote Control Electronic Ignition RC BATT HTL Battery Operated Remote Control Standing Pilot RCT MLT HTL Multi Function Remote Control SMART STAT HTL R...

Страница 22: ...3 9 8 5 2 l e n a P s s e c c A l o r t n o C 4 1 6 1 6 2 y l b m e s s A n e e r c S t n o r F 5 9 5 6 7 2 d o o H e d i S 6 3 1 9 5 2 e c a F d n E r e w o L 7 8 5 1 6 2 y l b m e s s A s s a l G d...

Страница 23: ...4 Cleaning 20 Specifications 4 Grounding 11 H High Altitude Installation 6 High Temperature Sealant 13 Hood 13 I Input Rate 9 10 Intermittent Pilot Ignition 11 15 17 J Junction Box Installation 12 L...

Страница 24: ...quate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other than those spe...

Отзывы: