01/04
11
CALIBER DESIGNER SERIES
4. Wiring
a. Intermittent Pilot Ignition
1)
This appliance requires a 110VAC supply to
the appliance junction box for operation. A
wiring diagram is shown in Figure 12.
2)
This appliance is equipped with an
intermittent pilot control valve which operates
on a 3V system.
3)
This appliance is supplied with a battery pack
and a 3VAC transformer, which requires the
installation of the supplied junction box. We
highly recommend that the junction box be
installed at this time to avoid reconstruction.
The battery pack requires two D cell batteries
(not included). Batteries cannot be placed in
the battery pack while using the 3VAC
transformer. Conversely, the transformer
must be unplugged if the battery pack is used.
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Elec-
tric Code, CSA C22.1
.
3. Gas Conversions
Natural or propane gas fuel conversions necessary
to meet the application need to be made by a qualified
technician using Hearth & Home Technologies
specified and approved parts.
In the event your appliance must be converted to
propane/standing pilot, use
CKVP
;
natural gas/standing pilot, use
CKVN
;
propane/intermittent pilot, use
DCKVP
;
natural gas/intermittent pilot, use
DCKVN
.
WARNING!
The gas control valve has been preset at the
factory. Altering settings may result in fire haz-
ard or bodily injury.
Figure 12
Intermittent Pilot Ignition Wiring Diagram
CAUTION:
Battery polarity must be correct or control mod-
ule damage will occur.