background image

Heatilator  •  ADI-ZC-FB  •  2032-900  Rev. E  •  8/05

22

Gas Appliance (Fireplace)

Limited Lifetime Warranty

HEARTH & HOME TECHNOLOGIES INC. (“HHT”)

 extends the following warranty for HEATILATOR

®

gas appliances installed in

the United States of America or Canada (the “Appliance”). Dealers and employees of HHT have no authority to make any warranty
or authorize any remedies in addition to or inconsistent with the terms of this warranty.

Limited Lifetime Warranty

HHT warrants the Appliance for component failure due to a manufacturing defect of any of the following components: combustion
chamber, burner pan, and logs. The Limited Lifetime Warranty specified above is subject to the conditions, exclusions and
limitations listed below, is for the period the Appliance is owned by the original homeowner only, and is nontransferable.

1 Year Limited Warranty

HHT warrants the Appliance to be free from failure of any of the following components for a period of one year after installation:
valve, flexible gas line connector, glass panel, fan, direct vent chimney components, factory paint, gasket, piezo ignitor, thermopile,
thermocouple, junction box, pilot assembly, shutoff valve, high limit switch, refractory liners, transformer, and control box. If the
Heatilator Appliance is found to be defective in either material or workmanship within one year of the date of original installation,
HHT will provide replacement parts at no charge and pay reasonable labor and freight costs, and is for the period of one year
following the date of original installation of the Appliance.

Conditions, Exclusions, & Limitations of  Liability

A.

Both the Limited Lifetime and 1 Year Limited Warranties supplied by HHT apply only while the Appliance is in its location of
original installation. HHT’s obligation under this warranty does not extend to damages resulting from (1) installation, operation
or maintenance of the Appliance not in accordance with the Installation Instructions, Operating Instructions, and the Listing
Agent Identification Label furnished with the Appliance; (2) installation which does not comply with local building codes; (3)
shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental
conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure, air handling devices such
as exhaust fans or forced air furnaces, or other causes;  (5) use of fuels other than those specified in the Operating
Instructions; (6) installation or use of components not supplied with the Appliance or any other components not expressly
authorized and approved by HHT; and/or (7) modification of the Appliance not expressly authorized and approved by HHT in
writing. This warranty is limited to only the component parts manufactured or supplied by HHT.

B.

HHT’s liability under both the Limited Lifetime Warranty and the 1 Year Limited Warranty is limited to the replacement and
repair  of defective components or workmanship during the applicable period.  HHT may fully discharge all of its obligations
under such warranties by repairing the defective component(s) or at HHT’s discretion, providing replacement parts at no
charge and paying reasonable labor and freight costs.

C.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY
SPECIFIED ABOVE.

D.

Some states do not allow exclusions or limitations of incidental or consequential damages, so those limitations may not apply
to you. This warranty gives you specific rights; you may also have other rights which vary from state to state.

How to Obtain Service

To obtain service under this warranty you must:

1.

Send written notice of the claimed condition to Heatilator Technical Service Department, Hearth & Home Technologies,
1915 W. Saunders Street, Mt. Pleasant, Iowa 52641-1563.  You may also register your claim online at www.heatilator.com/
contact.asp.

2.

Provide proof of purchase, model number, serial number, and manufacturing date code to HHT.

3.

Provide HHT reasonable opportunity to investigate the claim, including reasonable opportunity to inspect the Appliance
prior to any repair or replacement work and before the Appliance or any component of the Appliance has been removed
from the place of original installation.

4.

Obtain HHT’s consent to any warranty work before the work is done.

ADDITIONAL INFORMATION: 

If you would like information on current HEATILATOR products or want to locate a dealer in your

area, call 1-800-843-2848.

©

2005 Heatilator

®

 is a Registered Trademark of Hearth & Home Technologies Inc.

Содержание ADI-ZC-FB

Страница 1: ...H APPLIANCE FOR FUTURE REFERENCE 1 This appliance may be installed in an af termarket permanentlylocated manufac tured mobile home wherenotprohibited by local codes 2 This appliance is only for use wi...

Страница 2: ...ce front READ and UNDERSTAND all instructions carefully before starting the installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warran...

Страница 3: ...System 9 Step 2 Positioning Leveling and Securing the Insert 13 Step 3 The Gas Control Systems 13 Step 4 The Gas Supply Line 13 Step 5 Gas Pressure Requirements 14 Step 6 Wiring the Appliance 14 Wiri...

Страница 4: ...ed in accordance with local codes or in the absence of local codes with the National Electric Code ANSI NFPA No 70 in the United States or to the CSAC22 1 Canadian Electric Code in Canada These models...

Страница 5: ...EXTEN SION IF PRESENT MUST COMPLY WITH EI THER OF THE FOLLOWING 1 THE SOLID FUEL BURNING FIREPLACE MANUFACTURER S SPECIFICATION OR 2 LOCAL BUILDING CODES REQUIRED BY AUTHORITY HAVING JURISDICTION WAR...

Страница 6: ...R EXHAUST STARTING COLLAR ON OFF SWITCH OPTIONAL 3 SIDED ADI ZC FB MINIMUM FIREPLACE SIZE LOCATION Inches Millimeters A Front Width 30 7 8 784 B Rear Width 25 5 8 651 C Depth 15 381 Height 19 1 2 495...

Страница 7: ...the maximum vertical rise is 50 feet These dimensions are measured from the starting collars of the unit to the end of the last section of vent pipe See dimension V in Figure 3 Vent System Approvals...

Страница 8: ...E THE ROOF TOP THESE MINIMUM HEIGHTS ARENECESSARYINTHEINTEREST OF SAFETY SEE THE FOLLOWING DIAGRAM FOR MINIMUM HEIGHTS PROVIDED THE TERMINATION CAP IS AT LEAST 2 FEET FROM A VER TICAL WALL AND 2 FEET...

Страница 9: ...THE INLET AIR COLLAR OF THE UNIT AND EITHER ATTACHED TO THE INLETAIRCOLLAROFTHETERMINATIONCAP OR TERMINATED IN THE CHIMNEY This option shows both exhaust and inlet air vent pipes attached to the adapt...

Страница 10: ...KING HANDLE SLIDING PLATE STAINLESS STEEL ADAPTER FOR EXHAUST MUST BE INSTALLED INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK ZC ADPB For Flashing Class A Pipe TERMINATION CAP SQUARE FLASHING REMOVE...

Страница 11: ...building codes to properly size the gas supply line leading to the 1 2 inch 13 mm hook up at the unit This gas fireplace is designed to accept a 1 2 inch 13 mm gas supply line To install the gas supp...

Страница 12: ...ECT REMOTE CONTROLS IF AB SENT FOR EXTENDED TIME PERIODS THIS WILL PRE VENT ACCIDENTAL APPLIANCE OPERATION For Standing Pilot Ignition Wiring Appliance Requirements This appliance DOES NOT require 110...

Страница 13: ...glass doors JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110 120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BLK WHT GROUND WHT BLK BLK BLK REMOTE RECEPTACLE SPEED CONTRO...

Страница 14: ...oles in burner top see Figure 12 Space dime size ember pieces about a 1 2 inch apart Never press embers into burner ports DO NOT cover burner ports Place dime size pieces around front and sides of bur...

Страница 15: ...ew minutes for the lines to purge themselves of this air Once the purging is complete the appliance will light and will operate normally Subsequent lightings of the fireplace will not require this pur...

Страница 16: ...ILOT position turn the control knob counter clockwise to the PILOT position 6 To light the pilot press the control knob and then press the red or black piezo button once every second The piezo makes a...

Страница 17: ...vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically By Qualified service technician Home owner Task Make a...

Страница 18: ...copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts re...

Страница 19: ...necessary e Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glass soots a Flame impingement Adjust the log set so that the flame does not excessivel...

Страница 20: ...itions inadequate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other causes 5 use of fuels other th...

Отзывы: