18
Heatilator • ECO-ADV-WS22 • 7057-128D • September 15, 2011
• Frequency:
As desired
• By:
Homeowner
• Clean glass with a non-abrasive glass cleaner. Abrasive
cleaners may scratch and cause glass to crack.
• If the deposits on the glass are not very heavy, normal
glass cleaners work well. Heavier deposits may be
removed by using a damp cloth dipped in wood ashes or
by using a commercially available oven cleaner.
• After using an oven cleaner, it is advisable to remove any
residue with a glass cleaner or soap and water. Oven
cleaner left on during the next fi ring can permanently
stain the glass and damage the fi nish on plated metal
surfaces.
• A portion of the combustion air entering the fi rebox is de-
fl ected down over the inside of the door glass.
• This
air
fl ow “washes” the glass, helping to keep smoke
from adhering to its surface.
• When operated at a low burn rate, less air will be fl owing
over the glass and the smoky, relatively cool condition of
a low fi re will cause the glass to become coated.
•
Operating the appliance with the Burn Rate Air Control
in the High setting for 15-20 minutes should remove the
built up coating.
D. Glass Cleaning
CAUTION! Handle glass assembly with care. Glass is
breakable
.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
• Do not clean glass while it is hot
Replace the fi rebrick if they become, cracked, broken,
crumbly and/or if there is a 1/4 inch (6.35mm) gap between
the bricks.
The fi rebox is lined with high quality fi rebrick, which has
exceptional insulating properties. There is no need to
use a grate; simply build a fi re on the fi rebox fl oor. Do not
operate appliance without fi rebrick.
1. After the coals have completely cooled, remove all old
brick and ash from unit and vacuum fi rebox.
2. Remove new brick set from box and lay out to diagram
shown.
3. Lay bottom bricks in unit.
4. Install rear bricks on the top of the bottom bricks. Slide
top of bricks under clip on back of fi rebox wall and
push bottom of brick back.
5. Install side bricks. Slide top of brick under clips on
side of fi rebox and push the bottom of the brick until
it is fl ush with the side of the unit.
E. Firebrick Inspection
• Frequency:
After each ash removal
• By:
Homeowner
Figure 18.1
No.
Brick Size
Qty
1
9 x 4-1/2 x 1-1/4
20
2
9 x 2-1/4 x 1-1/4
4
Use Part 832-0550 when ordering individual brick.
Provide brick dimension or copy this page, mark
the desired brick and take it to your authorized
dealer.
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1