Requirements

•  The light control requires 120-volts AC.
•  If you want to use Manual Mode, the control must be 

wired through a switch.

• 

Some  codes  require  installation  by  a  qualified 
electrician.

•  This product is intended for use with the enclosed 

gasket and with a junction box marked for use in wet 
locations.

Model SL-5412

Light Control

Sensor

Cover 

Plate

Lamp Holders

2 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

2 Shells

Features

•  Turns on lighting when motion is detected.
•  Automatically turns lighting off. 
•  Photocell  keeps  the  lighting  off  during  daylight 

hours.

•  LED indicates motion was sensed (day or night).

Motion Sensor Light 
Control

Mounting Bolt

Mounting Strap

Plastic 

Hanger

Rubber Plug

OPERATION

* resets to Auto Mode at dawn.

Note:

  When first turned on wait about 1 

1

/

2

 minutes for 

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1

 TEST

10 5 1 

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF 

then...

Put the ON-TIME switch in the 1, 5, 
or 10 minute position.

Put the ON-TIME switch on the bottom 
of the sensor in the TEST position.

Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.

Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.

Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  10 
position.

Move ON-TIME Switch to 

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off 

for one second then 

back on*

MANUAL MODE

AUTO

TEST

*  If you get confused while switching modes, turn the 

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This package includes:

As an ENERGY STAR

®

 Partner, Heath

®

/Zenith 

has determined that this product meets the EN-
ERGY STAR

®

 guidelines for energy efficiency. 

This  product  is  ENERGY  STAR

®

  compliant 

when used with 120 Watt bulbs.

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Minutes

x

Manual

To Dawn*

x

2 Flood Lamps  

(some versions)

Содержание SL-5412

Страница 1: ...E ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswitchoffforonesecond thenbackontotogglebetweenAUTO and MANUAL MODE Manual mode works only with the ON TIM...

Страница 2: ...30 below horizontal Black to Black Junction box ground wire to green ground screw on fixture Gasket For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mou...

Страница 3: ...s 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable HeathCo LLC reserves the right to discontinue prod ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold Maximum Range Maximum Coverage Angle NOTE Sensor has a 1 1 2 minute warm up period before it will detect motion W...

Страница 4: ...u Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for incon venience installation setup time loss of use unauth...

Страница 5: ...el detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvaloaprenderparaconmutarentre MODO AUTOMATICO y MANUAL El modo manual funciona sólo con el interruptor ON TIME en la posición 1 5 ó 10 Mueva el interruptor de tiempo ON TIME a 1 5 ó 10 minutos Resumen de las modalid...

Страница 6: ...e en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detec tor debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Controles Controles Tornillo Sujetador Ajuste los portalámparas aflojando las contratuer cas pero no los gire más de 180 de la calibración hecha en fábrica Cuando atornille los proyectores no los apriete demasiado...

Страница 7: ...ustable HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo...

Страница 8: ...ionamiento ocasionado por partes defectuosas de fábrica o mano de obra será corregido sin cargo para Ud No cubierto Servicio de reparación ajuste y calibración debido al mal uso abuso o negligencia bombillas baterías u otras partes fungibles no están cubiertas por esta garantía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidarán esta garan...

Страница 9: ... de temps en circuit ON TIME du bas du détecteur Le mode manuel ne fonctionne que la nuit parce que la lumière du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en cir cuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne qu avec l interrupteur ON TIME aux positions 1 5 ou 10 Placer l interrupteur ON TIME à 1 5 ou 10 minutes ...

Страница 10: ...être tournées vers le bas Commandes Commandes Vis De Blocage Poussez le bouchon de caoutchouc fermement en place Si vous ne pouvez pas utiliser une boîte de jonction pourmilieuhumide calfeutrezlasurfacedemontage de la plaque murale avec un scellant silicone Raccorder le fil de terre de la boîte de jonction à la vis de terre verte sur l appareil Garder les lampes au moins 2 5 cm du capteur Nepasper...

Страница 11: ...andonner tout produit et d en changer les spécifications en tout temps et sans contracter quelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus Portée maximale Angle de couverture maximale NOTE Lecapteurdoitseréchauffer1 1 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est mis en circuit attendre 1 1 2 minute RANGE 10 5 1 T...

Страница 12: ...usions de la garantie Réparations réglage et calibrage dus à une mauvaise utilisation un mauvais traitement ou à la négligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autorisé ou la modification du produitoud unoul autredesescomposantsfournisinvalideratotalementlaprésentegarantie Cettegarantien inclutpasleremboursementpourle...

Отзывы: