598-1265-01

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Motion

Motion

The detector is most sensitive to motion across its field 
of view.

  Loosen the clamp screw in the 

sensor  ball  joint  and  gently 
rotate the sensor.

  Walk  through  the  coverage 

area  noting  where  you  are 
when the lights turn on (also, 
the LED will flash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 

Keep the sensor at 

least 1" (2.5 cm) away from 
the lamps.

  Adjust the RANGE as needed. 

RANGE  set  too  high  may 
increase false triggering.

 

Secure the sensor head by 
tightening the clamp screw.

 

Do not overtighten the screw.

  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with 

surrounding temperature].

Sensing Angle . . . . . . Up to 180°
Electrical Load . . . . . . Up  to  300  Watt  Maximum  In-

candescent  [Up  to  150  Watt 
maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST,  AUTO,  and  MANUAL 

MODE

Time Delay  . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable 
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features 
in products previously sold.

 

Maximum Range 

Maximum

 

 

Coverage Angle

NOTE:

  Sensor  has  a  1 

1

/

2

  minute  warm  up  period 

before it will detect motion. When first turned 
on, wait 1 

1

/

2

 minutes.

RANGE

10 5 1 TEST

ON-TIME

Bottom of Sensor

 

Avoid aiming the control at:

•  Objects  that  change  temperature  rapidly,  such  as 

heating  vents  and  air  conditioners.

  These  heat 

sources could cause false triggering.

•  Areas where 

pets or traffic

 may trigger the control.

•  

Nearby large, light-colored objects

 reflecting light 

may trigger the shut-off feature. Do not point other 
lights at the sensor.

70 ft.

(21 m)

8 ft.

(2.4 m)

180°

MIN 

MAX

  Least Sensitive 

 Most Sensitive

Sensor

 WARNING: Risk of fire. Do not aim the lamps 

at a combustible surface within 3 ft. (1 m).

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

  Turn the RANGE control to the mid position and the 

ON-TIME control to the TEST position.

Содержание SL-5412

Страница 1: ...E ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night because daylight returns the sensor to AUTO Flipthelightswitchoffforonesecond thenbackontotogglebetweenAUTO and MANUAL MODE Manual mode works only with the ON TIM...

Страница 2: ...30 below horizontal Black to Black Junction box ground wire to green ground screw on fixture Gasket For eave mount only Swing the sensor head towards the clamp screw joint If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mou...

Страница 3: ...s 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable HeathCo LLC reserves the right to discontinue prod ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold Maximum Range Maximum Coverage Angle NOTE Sensor has a 1 1 2 minute warm up period before it will detect motion W...

Страница 4: ...u Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for incon venience installation setup time loss of use unauth...

Страница 5: ...el detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector en modo AUTOMATICO Apague el interruptor por un segundo y vuélvaloaprenderparaconmutarentre MODO AUTOMATICO y MANUAL El modo manual funciona sólo con el interruptor ON TIME en la posición 1 5 ó 10 Mueva el interruptor de tiempo ON TIME a 1 5 ó 10 minutos Resumen de las modalid...

Страница 6: ...e en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detec tor debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Controles Controles Tornillo Sujetador Ajuste los portalámparas aflojando las contratuer cas pero no los gire más de 180 de la calibración hecha en fábrica Cuando atornille los proyectores no los apriete demasiado...

Страница 7: ...ustable HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad Alcance Máximo Angulo de Cobertura Máxima NOTA El detector tiene un período de cerca de 1 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo...

Страница 8: ...ionamiento ocasionado por partes defectuosas de fábrica o mano de obra será corregido sin cargo para Ud No cubierto Servicio de reparación ajuste y calibración debido al mal uso abuso o negligencia bombillas baterías u otras partes fungibles no están cubiertas por esta garantía Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidarán esta garan...

Страница 9: ... de temps en circuit ON TIME du bas du détecteur Le mode manuel ne fonctionne que la nuit parce que la lumière du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pendant une seconde plus en cir cuit pour alterner entre les modes AUTO et MANUEL Le mode manuel ne fonctionne qu avec l interrupteur ON TIME aux positions 1 5 ou 10 Placer l interrupteur ON TIME à 1 5 ou 10 minutes ...

Страница 10: ...être tournées vers le bas Commandes Commandes Vis De Blocage Poussez le bouchon de caoutchouc fermement en place Si vous ne pouvez pas utiliser une boîte de jonction pourmilieuhumide calfeutrezlasurfacedemontage de la plaque murale avec un scellant silicone Raccorder le fil de terre de la boîte de jonction à la vis de terre verte sur l appareil Garder les lampes au moins 2 5 cm du capteur Nepasper...

Страница 11: ...andonner tout produit et d en changer les spécifications en tout temps et sans contracter quelque obligation que ce soit quant à l incorporation de nouvelles caractéristiques aux produits déjà vendus Portée maximale Angle de couverture maximale NOTE Lecapteurdoitseréchauffer1 1 2 minuteavant de pouvoir détecter le mouvement Lorsque l appareil est mis en circuit attendre 1 1 2 minute RANGE 10 5 1 T...

Страница 12: ...usions de la garantie Réparations réglage et calibrage dus à une mauvaise utilisation un mauvais traitement ou à la négligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autorisé ou la modification du produitoud unoul autredesescomposantsfournisinvalideratotalementlaprésentegarantie Cettegarantien inclutpasleremboursementpourle...

Отзывы: