background image

4

595-5292-18

SYMPTOM

Lights will not come
on.

Lights come on
in daylight.

Lights come on for
no apparent rea-
son.

POSSIBLE CAUSE

1. Light switch is turned off.
2. Flood light is loose or

burned out.

3. Fuse is blown or circuit breaker is

turned off.

4. Daylight turn-off is in effect 

(re-

check after dark).

5. Incorrect circuit wiring, if this is a

new installation.

6. Re-aim the sensor to cover de-

sired area.

1. Light Control may be installed in

a relatively dark location.

2. Light Control is in Test.

(Set control switch to an
ON-TIME position).

1. Light Control may be sensing

small animals or automobile traf-
fic 

(re-aim sensor).

2. Sensitivity is set too high. 

(Re-

duce sensitivity.)

SYMPTOM

Lights stay on
continuously.

Lights flash on
and off.

POSSIBLE CAUSE

1. A flood lamp is positioned too close to

the sensor or pointed at nearby ob-
jects that cause heat to trigger the
sensor. 

(Reposition the lamp away

from the sensor or nearby objects).

2. Light Control is pointed toward a heat

source like an air vent, dryer vent, or
brightly-painted heat-reflective sur-
face. 

(Reposition sensor).

3. Light Control is in Manual Mode.

(Switch to Auto.)

1. Heat or light from the lamps may be

turning the Light Control on and off.
(Reposition the lamps away from the
sensor).

2. Heat being reflected from other ob-

jects may be affecting the sensor.
(Reposition sensor).

3. Light Control is in the Test mode and

warming up. 

(Flashing is normal un-

der these conditions).

4. Light may be leaking through the

floodlamp reflectors. 

(Replace the lamps

with new high quality PAR 38 lamps).

TROUBLESHOOTING GUIDE

TECHNICAL SERVICE

Please call 1-800-858-8501 for assistance before returning product to store.

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
ATTN: Technical Service Specialty Products
P.O. Box 90004, Bowling Green, KY 42102-9004
* If contacting Technical Service, please have the following information available: Model Number, Date of
Purchase, and Place of Purchase.

No Service Parts Available for this Product

TWO YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state
to state or province to province.
For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship
will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries,
and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or
of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for
inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and
components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE
FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO
LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS,
WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for
warranty claims.

Содержание SL-5408

Страница 1: ... min x Manual Until Dawn x OPERATION resets to Auto Mode at dawn Note When first turned on wait about 1 1 2 minutes for the circuitry to calibrate MANUAL MODE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME TEST back on AUTO 1 Second OFF then Put the ON TIME switch in the 1 5 or 10 minute position Put the ON TIME switch on the bottom of the sensor in the TEST position Manual mode only works at night becau...

Страница 2: ...ONTROL Rotate the sensor head towards the clamp screw joint Then rotate the sensor head clockwise 180 so the controls face down Control Switch Joint Clamp Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodlamps do not overtighten Keep lamps at least 1 25 mm from the sensor Avoid water damage and el...

Страница 3: ...lk through the coverage area noting where you are when the lights turn on Move the sensor head up down or sideways to change the cov erage area Keep the sensor at least 1 2 5 cm away from the lamps Adjust the SENSITIVITY as needed Too much sensitivity may increase false triggering Secure the sensor head by tighteningtheclampscrew Do not overtighten the screw Set the amount of TIME you want the lig...

Страница 4: ...rite to DESA Specialty Products ATTN Technical Service Specialty Products P O Box 90004 Bowling Green KY 42102 9004 If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product TWO YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have...

Страница 5: ...O Se pone en Automático al amanecer Para MODO MANUAL ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME Para PRUEBA préndalo Para AUTOMATICO 1 segundo APAGADO luego Ponga el interruptor de tiempo ON TIME en la posición de 1 5 ó 10 minutos Ponga el interruptor de tiempo ON TIME al fondo del detector en la posición de prueba TEST El modo manual funciona sólo por la noche porque la luz del día pone al detector ...

Страница 6: ... como se muestra en los dos pasos siguientes para evitar el riesgo de un choque eléctrico Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo Tornillo Sujetador Montaje en pared Montaje en alero Controles Para una fácil instalación escoja una luz con un interruptor de pared Para un mejor funcionamiento instale el aparato a casi 2 4 m del suelo Pe...

Страница 7: ...bilidad Hasta 110 Carga eléctrica Hasta 300 vatios máximo de luz incandescente hasta150 vatios máximo por cada portalámparas Requisitos de potencia 120 V ca 60 Hz Modos de operación PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 10 minutos Alcance Ajustable DESA Specialty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir ...

Страница 8: ... prende durante el día Laluzseprendesin ninguna razón aparente POSIBLE CAUSA 1 El interruptor de luz está apagado 2 El faro está flojo o fundido 3 El fusible está quemado o el cortacircuitos está apagado 4 La desconexión de luz del día está en efecto Compruébelo cuandocomiencelaobscuridad 5 Alambrado incorrecto si ésta es una nueva instalación 6 No está apuntando correctamente Apunte de nuevo el d...

Страница 9: ...nction Jour Nuit Essal 5 secondes x x Auto 1 5 ou 10 min x Manuel au choix x amanecer FONCTIONNEMENT Revient au mode automatique au lever du soleil PRIORITÉ MANUELLE ON TIME 10 5 1 TEST 10 5 1 TEST ON TIME ESSAI back on AUTOMATIQUE 1 Second OFF then Amener l interrupteur de temps en circuit ON TIME à la position correspondant à 1 5 ou 10 minutes Amener en position d essai TEST l interrupteur de te...

Страница 10: ... commandes soient tournées vers le bas Commandes Vis De Blocage Ajuster les porte lampes en desserrant les écrous de blocage mais ne pas faire tourner les porte lampes de plus de 180 par rapport au réglage d usine Ne pas trop serrer les lampes dans les porte lampes Ajusterlesdouillesde façon que les lampes setrouventàaumoins 25 mm du détecteur Pour éviter les dommages par l eau et les risques de c...

Страница 11: ... 110 Charge électrique Jusqu à deux ampoules incandescentes pour un maximum de 300 W maxi mumde150Wparsupport Alimentation électrique 120 V CA 60 Hz Modes de fonctionnement Essai automatiqueetpriorité manuelle Délais 1 5 et 10 minutes Portée Réglable DESA Specialty Products se réserve le doit d abandonner tout produit et d en changer les spécifications entouttempsetsanscontracterquelque obligation...

Страница 12: ... il est nécessaire de présenter une preuve d achat SYMPTÔME L éclairage ne s allume pas L éclairage s allume en plein jour L éclairage s allume sans raison apparente CAUSE POSSIBLE 1 L interrupteurd éclairageesthors tension 2 Leprojecteurestdévisséoubrûlé 3 Lefusibleasautéouledisjoncteur a été déclenché 4 Le dispositif de coupure pendant le jour fonctionne Vérifiez à nouveau à la noirceur 5 Mauvai...