For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8
feet (2.4 m) above the ground.
NOTE: If fixture is
mounted higher than 8 ft. (2.4 m), aiming the sen-
sor down will reduce coverage distance.
W
ire
the
L
ight
C
ontroL
For eave mount only:
Wall Mount
Eave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
❒
Rotate the sensor head towards the clamp screw
joint.
❒
Then rotate the sensor head clockwise 180° so the
controls face down.
Control Switch
Joint Clamp
Black to Black
White to White
Gasket
❒
Drill the holes needed
to mount the backplate
to the junction box.
❒
Remove the existing light fixture.
❒
Route the light control's wires through the large
gasket hole.
❒
Connect the junction box wires to the light control
wires. Twist together and secure with a wire
connector.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
WARNING: Turn power off at circuit breaker
or fuse.
Flash Alert - Activated
(Blue)
NOTICE: 5410 models with Flash Alert feature will
also have a wire loop which can be used to disable
the flash alert feature. This wire loop should not
be connected to any other wire.