background image

 

 

 

ODORATOR 2

TM

 

Operator

’s Manual 

All Models 

   

 

 
 
 

 
 

 

 
 
 
 
 

Содержание Odorator 2

Страница 1: ...ODORATOR 2TM Operator s Manual All Models...

Страница 2: ...onsent of Heath Consultants Incorporated Heath Consultants Incorporated operates under a continual product improvement program and reserves the right to make improvements and or changes without prior...

Страница 3: ...Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Tel 713 844 1300 www heathus com ODORATOR 2 Operator s Manual Models 1 00 Methane 0 50 Methane 0 15 Methane 0 44 Propane...

Страница 4: ...ocedure 7 Bluetooth 10 ODORATOR 2 Operator Controls and Connectors 10 Figure 1 ODORATOR 2 Top Panel Layout 10 Figure 2 ODORATOR 2 Rear Case View 11 Battery Charging 11 Battery Pack Replacement 12 CHAP...

Страница 5: ...to show the actual breadcrumb trail used The electronics and the speed of the blower are calibrated so that the concentration of the gas air sample at the exhaust port agrees with the LCD reading at 2...

Страница 6: ...S MORE THAN FOUR PSIG COULD RUPTURE THE LOW PRESSURE REGULATOR DIAPHRAM VENT THE GAS OUT OF THE INSTRUMENTAND CAUSE INSTRUMENTFAILURE THE RECOMMENDED INLET SUPPLY PRESSURE IS 7 WATER COLUMN WHEN OPERA...

Страница 7: ...THE RISK OF IGNITION OF A FLAMMABLE OR EXPLOSIVE ATMOSPHERE ANY CABLE POWER or USB MUST ONLY BE CONNECTED IN A LOCATION KNOWN TO BE NON HAZARDOUS DO NOT OBSTRUCT OR BLOCK THE INTAKE OR EXHAUST PORTS...

Страница 8: ...nt for Type 3R testing UL50 CSA 22 2 No 94 1 12th edition Battery Pack Run Time Internal rechargeable Li Ion 3 weeks typical run time Battery Charger Power Supply External in line 110 240 VAC 1 6A 50...

Страница 9: ...of affecting their sense of smell Proper use of the ODORATOR 2 requires an operator with a normal sense of smell List of Contents The following items are included with the ODORATOR 2 1 ODORATOR 2 ins...

Страница 10: ...ibration 12 CAL OK 13 A live reading display in Gas unit The actual battery capacity will be shown on the bar graph on the left side of the display The turn on sequence will generally take 20 30 secon...

Страница 11: ...ed and the ODORATOR 2 turned OFF Odor Threshold Level and Relative Odor Intensity Tests Procedure 1 Prior to attaching the sample hose sniff the sample hose and verify no odor is detected If odor is d...

Страница 12: ...ten only 7 Wait about 30 seconds and then position the nose approximately 3 4 inch 20 mm above the exhaust port and sniff the exhaust The exhaust must be un odorized If odorant is detected the ODORATO...

Страница 13: ...shown on the display The display count will change by one for each or key press and alternate between ROI and the count value For example after 5 key presses 5 0 80 would indicate a rating of 5 relati...

Страница 14: ...ndle is included for sample hose and fittings storage Bluetooth NOTE Bluetooth hardware is installed and configured but connectivity is not supported A future firmware and OdorSeer OdorSeer Remote rel...

Страница 15: ...leep The ODORATOR 2 must be recharged in this case prior to use NOTE In order to obtain full battery capacity charge the battery pack when the ambient temperature is above 50 F 10 C and below 85 oF 30...

Страница 16: ...the top of the cover slightly out then up to remove the cover 5 Squeeze the cable connector s lock to disengage and unplug the battery from its extension cable 6 Plug in the new battery pack The inst...

Страница 17: ...forms on pages 16 and 17 are provided to document the Periodic Tests as a courtesy only Your Company s procedures will define how records are kept and in what format Calibration For regulatory complia...

Страница 18: ...always detected Contaminated sample hose or flow system Change tubing RMA The RMA process may be found on page 18 of this manual Parts List The following list specifies ODORATOR 2 parts and accessori...

Страница 19: ...or this test may be found on page 13 of this manual The forms on pages 16 and 17 are provided for your convenience They should remain in the manual and be kept in a safe location as a permanent record...

Страница 20: ...16 Periodic Test Records Test Date Results Action Operator Name...

Страница 21: ...17 Periodic Test Records Test Date Results Action Operator Name...

Страница 22: ...er than a Heath warranty repair location Batteries and damage from battery leakage and all expendable items such as filters and tubing are excluded from this warranty Heath s responsibility is express...

Страница 23: ...air form requests information such as complete shipping and billing addresses instrument or product name model number and serial numbers Also included will be a brief description of the problem you ar...

Страница 24: ...061 Model Odorator 2 Has been demonstrated to be in compliance with the European EMC directive 2004 108 EC FCC 47 CFR Part 15 and Industry Canada ICES 003 and is in accordance with the following stand...

Страница 25: ...Park Way Monongahela PA 15063 Phone 724 242 3145 Fax 724 872 3206 Southwest Region Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Phone 713 844 1300 Fax 713 844 1309 Western Region H...

Страница 26: ...22...

Страница 27: ...__________________________________________________________________ ___________________________________________________________________________ _________________________________________________________...

Страница 28: ...Heath Consultants Incorporated 9030 Monroe Road Houston TX 77061 Tel 713 844 1300 www heathus com...

Отзывы: