HeatFab Saf-T Liner Скачать руководство пользователя страница 1

1

Model Saf-T Liner

Installation and Maintenance Instructions

Stainless Steel Chimney Liner

For Installation into an existing Masonry Chimney.

Saf-T Liner is designed for an installation by a qualified

person in accordance with local building codes.

4”, 5”, 6”, 7” and 8” diameters - 9”, 10”, 12” and 14”

available upon request.

IMPORTANT: A major cause of vent related fires is failure to

maintain required clearances (air spaces) to combustible

materials.  It is of the utmost importance this Saf-T Liner be

installed only in accordance with these instructions.

Do not install this product until you have read and fully

understand these installation instructions.

Saf-T Liner has been tested and listed using all the supports,

sections, etc., described herein.  Deletion or modification of any

of the required parts or materials may seriously impair the safety

of your installation, and void the conditions of certification and

or the manufacturers warranty.

Keep these instructions in a safe place for future reference.

•  

Stainless Steel 304 or 316

  Continuous Laser Welded Seams

  Straight Male and Female Ends

  Tested & Listed to UL 1777

5030 Corporate Exchange Blvd

Grand Rapids, MI 49512

Call 800-433-6341

www.heatfab.com

Failure to follow the installation instructions
could cause FIRE, CARBON MONOXIDE
POISONING, OR DEATH.  If you are unsure of
installation requirements, call the phone
number listed on the instructions,
1.800.433.6341 or visit 

www.selkirkcorp.com

.

!   WARNING

 

LISTED

Содержание Saf-T Liner

Страница 1: ...on instructions Saf T Liner has been tested and listed using all the supports sections etc described herein Deletion or modification of any of the required parts or materials may seriously impair the...

Страница 2: ...he roof of a building and not less than 2 feet above any portion of the building within ten feet see Fig 1 Materials 024 304 Stainless Steel 024 316L Stainless Steel Includes 1 8 Stainless Steel Blind...

Страница 3: ...2 and Figure 2 Saf T Wrap is available for tee sections and in 24 lengths Saf T Wrap must cover the Saf T Liner from the appliance tee or the top of the smoke chamber area to within 8 but not closer...

Страница 4: ...A B Always wear eye protection and heavy gloves throughout installation Wear eye protection and dust respirator whenever in contact with creosote soot mortar or insulation Before the installation of t...

Страница 5: ...assembly will be supported from the top of the chimney The installer must verify that there is at least 1 inch clearance to combustibles outside a 3 nominal layer of masonry as well as 1 inch clearan...

Страница 6: ...horizontal run FIXED LENGTHS Saf T Liner is available in 12 18 24 36 and 48 fixed Lengths To determine the length and number of liner sections required complete the following Calculate the number of...

Страница 7: ...ze can have a negative impact of chimney performance and safety Use these components only when appropriate See Fig 13 RAIN CAP Saf T Liner Rain Cap is made of stainless steel and required to cap the l...

Страница 8: ...it may need to be expanded in order to insert the tee take off into the removable tee or accommodate the support system chosen To make the initial opening into the masonry chimney select a brick that...

Страница 9: ...ON CAUTION must be used when working on a roof Proper and safe scaffolding should be used for a safe installation of the Saf T Liner Always use a respirator and eye protection when using Saf T Wrap MA...

Страница 10: ...p Plate supporting the upper sections of the liner system Slide the Rain Cap into the female portion of the Saf T Liner section and secure with the four self drilling screws provided See Figs 5 and 25...

Страница 11: ...is not used the single wall connector pipe must be at least 18 from combustible construction material Clearances from the solid fuel burning appliances to combustible materials must be strictly adhere...

Страница 12: ...y walls and cause cracking buckling distortion and or burnout in chimney liners A chimney liner damaged in such a way as to permit leakage of flue gases should be repaired or replaced Since there is a...

Страница 13: ...workmanship For products installed after January 1 2009 for a period of Ten 10 years from original installation we will provide replacement product with a similar or like quality of available Selkirk...