Figure 4.3 Passive Heat Open Top Discharge Configuration Options
Chase Configurations Passive Heat Open Top Discharge (Single-Sided or See-Through)
SINGLE-SIDED APPLIANCE
SEE-THROUGH APPLIANCE
BACK
SIDE
2 IN. MIN.
FRONT
SIDE
FRONT
FRONT
SIDE
SIDE
CEILING
CEILING
REAR SUPPORT
STUD
2 IN. MIN.
Figure 4.3 shows the acceptable configurations for Open
Top Discharge.
For a
See-Through
appliance, two options are available:
Option 1: Both “Front” sides are open top configuration.
Option 2: One “Front” side is open top configuration.
For See-Through models, sides are not required to be
open, but at least one front side of the chase MUST be
open and unobstructed.
WARNING! Risk of Fire!
Comply with Open Top Dis-
charge configurations as specified. Reduced discharge
area will interfere with proper operation of the heat man-
agement system. Overheating of appliance and combus-
tible materials will occur.
Open Top Discharge Configuration
1. Dimensions for framing using the Open Top Discharge
method of installation are shown in Figure 4.2.
WARNING! Risk of Fire!
Mesh screen required on top
of framing when discharge opening is greater than two
inches.
Open Top Discharge - Clearances to Combustibles
2. If Dimension E in Figure 4.2 is greater than two
inches, a piece of mesh screen with 1/2 inch x 1/2
inch opening
MUST
be installed on the top of the
framing above the appliance.
The screen will prevent objects from falling through
the opening and onto the top of the appliance,
causing a fire. The mesh screen may be available at
a hardware or home improvement retailer.
For a
Single-Sided
appliance, the front and both sides
of the chase MUST be open and unobstructed. A rear
support stud may be installed along the back wall to ensure
secure mounting of the discharge assembly.
WARNING! Risk of Fire!
Minimum dimension of opening
MUST
be 2 inches! Appliance and combustible materials
will overheat.
WARNING! Risk of Fire! DO NOT
block discharge opening!