18
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
13. Secure flex venting to collars on both the appliance
and the bottom of the plenum using the provided gear
clamps. See Figure 6.18 and Figure 6.20.
Figure 6.18 Install Flex Venting to Appliance
Figure 6.20 Flex Vent Installed with No Kinks
BACK SIDE: LOCATION OF
FINISHING TRIM PIECE
(See Figure 6.5.)
14. Install self-tapping screw through gear clamp into col-
lar. Repeat for all collars. See Figure 6.19
Figure 6.19 Install Screw into Collar
SCREW
WARNING! Risk of Fire! DO NOT
fold/kink/pinch/
obstruct 6 inch flexible ducts. Appliance and combustible
materials could overheat.