27
Heat & Glo •
PHFR-PRIMO-48, PHFR-PRIMO-60, PHSI-PRIMO
Instructions • 2560-970 Rev. D • 2/19
8. On a flat surface, mount a mounting bracket
assembly to the end of the nailing tabs on each side
of the discharge assembly. See Figure 8.12. Make
sure that the discharge assembly is centered on the
mounting bracket assembly as shown in Figure 8.13.
Repeat this process for both discharge assemblies.
CENTER ON
MOUNTING
BRACKET
Figure 8.12 Mounting Bracket Assembly Fastened to Nailing Tabs
Figure 8.13 Center Discharge Assembly on Mounting Bracket
9. Mount the 12 inch x 8 inch register cover to the
discharge assemblies register cover tabs using the
screws provided with the cover. See Figure 8.14.
Figure 8.14 Louvers Face Front of Appliance
MOUNTING BRACKET
NAILING TAB (X4)
Note:
An unobstructed gap measuring a minimum of two
inches from the room ceiling to the top of the mounting
bracket is necessary for the open top discharge to prop-
erly function.
Note:
If discharge assemblies are mounted too close to-
gether, possible vent runs will be limited as SLP pipe will
not fit in between the mounted discharge assemblies.
10. Mark out the location that each discharge assembly
is to be mounted. The discharge assembly should be
mounted as close to centered over the Passive Heat
collar on the appliance as possible.
11. Mount the discharge assemblies assembled with the
mounting bracket assemblies to the wall using the
provided wood screws. Be sure that the louvers on
the register cover face the discharge opening on the
front of appliance.
Note:
The mounting bracket assemblies must be screwed
into a stud or wall anchor for proper support.
Figure 8.15 Mark Mounting Location for Discharge Assembly
Figure 8.16 Mounted Discharge Assembly
LOUVERS FACE
FRONT OF APPLIANCE