45
Heat & Glo • HE36CLX-S • 2183-900 Rev. H • 1/14
C. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or
fi
nishing materials must not interfere with
air
fl
ow through louvers, operation of doors, or access
for service or separation of
fi
rebox from outer appliance
wrap.
• Facing and/or
fi
nishing materials must never overhang
the top edge of the
fi
rebox or separation of
fi
rebox and
appliance outer wrap will not be possible.
• Observe all clearances when applying combustible
materials.
WARNING! Risk of Fire! DO NOT
apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci
fi
ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as speci
fi
ed. Framing closer than the minimums list-
ed must be constructed entirely of non-combustible materi-
als (i.e., steel studs, concrete board, etc.).
Combustible Mantels
Combustible Mantel Legs or Wall Projections
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note:
All measurements in inches.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
Millimeters
25
51
76
102
127
Note:
Measurement is taken from top of the
opening, NOT the top of the
fi
replace.
Figure 15.9 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
Figure 15.8 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles