B.  Assemble Slip Sections

•  Slide the inner flue of the slip section into the inner flue 

of the pipe section and the outer flue of the slip section 

over the outer flue of the pipe section. See Figure 10.5.

•  Slide together to the desired length.

Figure 10.5  Slip Section Pilot Holes

Figure 10.6  Screws into Slip Section

Pilot hole

•  Continue adding pipe as necessary following instructions 

in “Assembling Pipe Sections.”

NOTICE: 

If slip section is too long, the inner and outer flues 

of the slip section can be cut to the desired length.

•  Maintain a 1-1/2 in. (38 mm) overlap between the slip 

section and the pipe section.

•  Secure  the  pipe  and  slip  section  with  two  screws  no 

longer than 1/2 in. (13 mm), using the pilot holes in the 

slip section. See Figure 10.6.

120º

Figure 10.7  Securing Vertical Pipe Sections

120º

Figure 10.8  Securing Horizontal Pipe Sections

C.  Secure the Vent Sections

•  Vertical runs originating off the top of the appliance, with 

no offsets, must be supported every 8 ft. (2.44 m) after 

the maximum allowed 25 ft. (7.62 m) of unsupported rise.

•  Vertical runs originating off the rear of the appliance, or 

after any elbow, must be supported every 8 ft. (2.44 m). 

•  Horizontal runs must be supported every 5 feet (1.52 

m).

•  Vent supports or plumbers strap (spaced 120º apart) 

may be used to support vent sections. See Figures 10.7 

and 10.8

•  wall shield firestops may be used to provide horizontal 

support to vent sections. 

WARNING! Risk of Fire, Explosion or Asphyxiation! 

Improper  support  may  allow  vent  to  sag  and  separate. 

Use vent run supports and connect vent sections per in-

stallation instructions. 

DO NOT

 allow vent to sag below 

connection point to appliance. 

Содержание CERONA-36

Страница 1: ...rofessionals or technicians supervised by an NFI certified professional DO NOT DISCARD Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter See Table of Contents for location of additional Commonwealth of Mass...

Страница 2: ...ntre utilise utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes codes if if any any if if not not follow follow ANSI ANSI Z223 1 Z223 1 in in the the USA USA or or CAN CGA CAN CGA B149 B149 installation installation codes codes Installer Installer l appareil l appare...

Страница 3: ...ded 17 D Inspect Appliance and Components 17 5 Framing and Clearances A Selecting Appliance Location 18 B Constructing the Appliance Chase 19 C Clearances 19 D Mantel and Wall Projections 20 E Hearth Extension 21 6 Termination Locations A Vent Termination Minimum Clearances 22 7 Vent Information and Diagrams A Approved Pipe 24 B Vent Table Key 24 C Use of Elbows 24 D Measuring Standards 24 E Addin...

Страница 4: ...bly 49 B Remove the Shipping Materials 49 C Inspect Firebox 49 D Clean the Appliance 49 E Accessories 49 F Ember Placement 49 G Positioning the Logs 50 H Fixed Glass Assembly 54 I Grilles and Trim 54 J Air Shutter Setting 55 K Install Mesh 55 L Install Trim and or Surround 55 15 Troubleshooting A Intellifire Ignition System 56 16 Reference Materials A Appliance Dimension Diagram 58 B Vent Componen...

Страница 5: ...purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the installation or occupancy date The warranty...

Страница 6: ...ECIFIEd ABoVE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other e...

Страница 7: ...ical codes when it is installed in locations such as in bathrooms or near sinks NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It should not be factored as primary heat in residential heating calculations D High Altitude Installations NOTICE If the heating value of the gas has been reduced these rul...

Страница 8: ...ed heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizon tally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob serves carbon monoxide detectors and signage installed in acc...

Страница 9: ...able materials Clothing furniture draperies and other flammable materials must not be placed on or near the appliance Young children should be carefully supervised when they are in the same room as the appliance Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fi...

Страница 10: ...corative door or front G Remote Controls Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions CLEAR SPACE 3 FT IN FRONT OF FIREPLACE H Before Lighting Fire...

Страница 11: ... floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL VALVE Improper installation adjustment al teration service or maintenance can cause injury or property damage Re fer to the...

Страница 12: ... to burn for 20 to 40 minutes Odor from fireplace When first operated this fireplace may release an odor for the first several hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Odor may also be released from finishing materials and adhesives used around the fireplace Film on the glass This is a normal result of the curing process of the pa...

Страница 13: ...quired due to lint from carpeting or other factors Control compartment burner and circulating air passageway of the fireplace must be kept clean CAUTION Risk of Burns The fireplace should be turned off and cooled before servicing When properly maintained your fireplace will give you many years of trouble free service We recommend an nual service by a qualified service technician Doors Surrounds Fr...

Страница 14: ...ves vacuum cleaner dust cloths Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove all foreign objects Verify unobstructed air circulation Burner Ignition and Operation Frequency Annually By Qualified Service Technician Tools needed Protective gloves vacuum cleaner whisk bro...

Страница 15: ...aint condition warped surfaces corrosion or perforation Sand and repaint as necessary Replace appliance if firebox has been perforated Surface cracking or crazing of firebrick material is normal and expected All cracks are acceptable and do not require replacement of the unit or the firebox with the exception of Cracks compromising the surface plane of the firebox See Figure 3 2 Figure 3 2 Surface...

Страница 16: ... SECTION 10 H VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAFTERS SECTION 10 F FRAMING HEADED OFF IN CEILING JOISTS SECTION 8 B AND 8 C GAS LINE SECTION 11 C MANTEL AND MANTEL LEG SECTION 5 D HEARTH EXTENSION SECTION 5 E VENT PIPE SECTIONS 7 and 8 STORM COLLAR SECTION 10 G NON COMBUSTIBLE ROOF FLASHING MAINTAINS MINIMUM CLEARANCE AROUND PIPE SECTION 10 F FRAMING HEADER SECTION 5 B ...

Страница 17: ...sion Damaged parts could impair safe operation DO NOT install damaged in complete or substitute components Keep appliance dry C Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Tape measure Framing material Pliers Hammer Phillips screwdriver Manometer Gloves Framing square Voltmeter Electric drill and bits 1 4 in Plumb...

Страница 18: ... and draperies NOTICE Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY Illustrations diagrams are not drawn to scale Actual installation may vary due to individual design preference Figure 5 1 Appliance Locations In addition to these framing dimensions also reference the following sections Clearances and Mantel Projections Sections 5 C 5 D and 5 E Vent Clearances and Fr...

Страница 19: ...ces to Combustibles C Clearances NOTICE Install appliance on hard metal or wood surfaces extending full width and depth DO NOT install directly on carpeting vinyl tile or any combustible material other than wood WARNING Risk of Fire Maintain specified air space clearances to appliance and vent pipe Insulation and other materials must be secured to prevent accidental contact The chase must be prope...

Страница 20: ... 2 3 4 5 6 7 8 9 10 11 12 TOP OF ARCH OPENING CEILING A B C MAXIMUM A B C D E Cerona 36 in 32 1 4 16 3 4 16 11 49 mm 819 425 406 279 1245 Cerona 42 in 28 1 2 16 3 4 16 11 45 1 4 mm 724 425 406 279 1149 A TOP VIEW B MANTEL LEG OR WALL PROJECTIONS INTERIOR WALL If A minimum is _____ then B maximum is ______ A in 1 2 3 4 5 6 7 8 9 10 11 12 mm 25 51 76 102 127 152 178 203 229 254 279 305 B in 1 2 3 4 ...

Страница 21: ...BUSTIBLE SURFACE MARBLE GRANITE TILE OR OTHER NON COMBUSTIBLE HEARTH EXTENSION BOTTOM OF FIREPLACE Figure 5 7 Fireplace sitting on combustible surface Figure 5 8 Fireplace raised a minimum of 6 inches away from combustible surface BOTTOM OF FIREPLACE SURFACE MAY BE COMBUSTIBLE COMBUSTIBLES UP TO 1 INCH THICK ALLOWED UNDER THE OPENING 6 INCHES MINIMUM 1 INCH MAX TO ALLOW FOR DOOR CLEARANCE The base...

Страница 22: ...HES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING 6 Termination Locations Fire Risk Maintain vent clearance to combustibles as specified DO NOT pack air space with insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause overheating and fire WARNING Figure 6 2 Staggered Termination Caps Gas Wood or Fuel Oil Termination Cap B Gas Ter...

Страница 23: ...s non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMAX 2 termination caps x QACTUAL Covered Alcove Applications Spaces open only on one side and with an overhang Measure...

Страница 24: ...length of straight pipe is allowed between two 45º elbows see Figure 7 1 Figure 7 1 7 Vent Information and Diagrams B Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams D Measuring Standards Vertical and horizontal measurements listed in the vent diagrams were made using the following standards Pipe measurements are shown using the effective length of pipe...

Страница 25: ...d down Secure the heat shield to the pipe maintaining 3 inch to 4 inch between the pipe and shield Refer to Cinch Pipe and Termination Cap installation in structions Continue adding vent components locking each succeeding component into place Ensure that each succeeding vent component is securely fitted and locked into the preceding component in the vent system 90º elbows may be installed and rota...

Страница 26: ...4 mm 8 ft 2 4 m 4 ft 1 2 m 11 ft 3 4 m 5 ft 1 5 m 14 ft 4 3 m 6 ft 1 8 m 17 ft 5 2 m 7 ft 2 1 m 20 ft 6 1 m 8 ft 2 4 m 23 ft 7 0 m V1 40 ft 12 2 m Maximum H1 23 ft 7 0 m Maximum V1 H1 63 ft 19 2 m Maximum Note Must have a minimum verti cal vent before attaching a 90º elbow to the unit See chart Minimal Vertical Vent Model ft mm Cerona 36 1 2 152 Cerona 42 1 305 V1 Minimum H1 H2 Maximum Cerona 36 O...

Страница 27: ...ft 2 1 m 3 ft 914 mm 10 ft 3 0 m 4 ft 1 2 m 13 4 0 m 5 ft 1 5 m 16 4 9 m 6 ft 1 8 m 17 5 2 m 7 ft 2 1 m 22 6 7 m H1 H2 22 ft 6 7 m Max V1 V2 H1 H2 62 ft 18 9 m Max H2 H1 V2 V1 CAP V1 Figure 7 9 Note On vertical venting configurations install the flue restrictor found in the appliance manual bag Follow flue restrictor instructions in Section 9 D Note Must have a minimum verti cal vent before attach...

Страница 28: ...wo Elbows H1 V2 V1 V1 Minimum H1 H2 Maximum Cerona 36 ONLY 1 2 ft 152 mm 3 ft 914 mm 1 ft 305 mm 4 ft 1 2 m 2 ft 610 mm 7 ft 2 1 m 3 ft 914 mm 10 ft 3 0 m 4 ft 1 2 m 13 4 0 m 5 ft 1 5 m 16 4 9 m 6 ft 1 8 m 17 5 2 m 7 ft 2 1 m 22 6 7 m H1 H2 22 ft 6 7 m Max V1 V2 H1 H2 62 ft 18 9 m Max Note Must have a minimum verti cal vent before attaching a 90º elbow to the unit See chart Minimal Vertical Vent M...

Страница 29: ... clearance around vertical sections B Wall Penetration Framing Combustible Wall Penetration Whenever a combustible wall is penetrated you must frame a hole for the wall shield firestop s The wall shield firestop maintains minimum clearances and prevents cold air infiltration The opening must be framed on all four sides using the same size framing materials as those used in the wall construction DV...

Страница 30: ...ent overheating Figure 8 3 Installing Ceiling Firestop Figure 8 4 Installing the Attic Shield INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP INSTALLED BELOW CEILING CEILING FIRESTOP INSTALLED ABOVE CEILING ATTIC ABOVE A PIPE DVP A 10 in 254 mm A D Install Attic Insulation Shield WARNING Fire Risk DO NOT allow loose materials or insulation to touch ven...

Страница 31: ... ZONE HEAT DUCT KNOCKOUT Heat Zone Determine the location for the air register fan housing assembly Heat Duct Determine the location of the entry in the air duct system Reference the Heat Zone Heat Duct Kit instructions for the remaining installation steps Note Center the duct collar around the exposed hole and attach it to the appliance with 3 screws BEFORE final positioning of the appliance ...

Страница 32: ...n backing or plastic Framing and other combustible materials Block openings into the chase to prevent entry of blown in insulation Make sure insulation and other materials are secured DO NOT notch the framing around the appliance standoffs Failure to maintain air space clearance may cause overheating and fire The diagram shows how to properly position and secure the appliance see Figure 9 2 Nailin...

Страница 33: ...s acceptable to use wood shims Bend out nailing tabs on each side Keep nailing tabs flush with the framing Secure the appliance to the framing by using nails or screws through the nailing tabs APPLY FASTENERS FROM FASTENER PACKET IN SHADED AREAS WARNING WARNING Fire Risk Maintain specified clearances around the appliance DO NOT notch into the framing around the appliance spacers Attach the left an...

Страница 34: ...etermine which restrictors to use for the vent run Vent Run Vertical 15 ft 50 ft Cerona 36 1 1 4 Cerona 42 1 1 4 Figure 9 5 BOTTOM OF FIREPLACE TOP OF FIREPLACE EXHAUST COLLAR EXHAUST PORT SCREWS FIREBOX FLUE RESTRICTOR FLUE RESTRICTOR FLAPPER DOOR FLAPPER DOOR EXHAUST COLLAR EXHAUST PORT SCREWS 2 Mount the flue restrictor to the flapper door using two screws see Figure 9 5 ...

Страница 35: ...For 90º and 45º elbows that are changing the vent direction from horizontal to vertical one screw minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating Use screws no longer than 1 2 in 13 mm If predrilling screw holes DO NOT penetrate inner pipe Commercial Multi family Multi level exceeding two sto ries or High Rise Applications All outer pipe joi...

Страница 36: ...e pilot holes in the slip section See Figure 10 6 120º Figure 10 7 Securing Vertical Pipe Sections 120º Figure 10 8 Securing Horizontal Pipe Sections C Secure the Vent Sections Vertical runs originating off the top of the appliance with no offsets must be supported every 8 ft 2 44 m after the maximum allowed 25 ft 7 62 m of unsupported rise Vertical runs originating off the rear of the appliance o...

Страница 37: ...em on the ceiling and drill a small hole through the ceiling and roof at this point Locate the hole and mark the outline of the cathedral ceiling support box on the outside roof Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3 mm larger than the support box outline Lower the support box through the hole in the roof until its ...

Страница 38: ...INIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Figure 10 15 Assembling the Storm Collar Around the Pipe Figure 10 14 CAULK NOTICE Failure to properly caulk the roof flashing and pipe seams may permit entry of water Caulk the gap between the roof flashing and the outside diameter of the pipe Caulk the perimeter of the flashing where it contacts the roof surface See Figure 10 14 Caulk the overl...

Страница 39: ...elds must overlap 1 1 2 in 38 mm mini mum There are two sections of the heat shield One section is factory attached to the wall shield firestop The other section is factory attached to the cap See Figure 10 17 If the wall thickness does not allow the required 1 1 2 in 38 mm heat shield overlap when installed an extended heat shield must be used If the wall thickness is less than 4 in 102 mm DVP or...

Страница 40: ...essed in the wall Siding may be brought to the edge of the cap base Flash and seal as appropriate for siding material at outside edges of cap When installing a horizontal termination cap follow the cap location guidelines as prescribed by current ANSI Z223 1 and CAN CGA B149 installation codes and refer to Section 6 of this manual CAUTION Risk of Burns Local codes may require in stallation of a ca...

Страница 41: ...OT use open flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Explosion High pressure will damage valve Low pressure may cause explosion Verify inlet pressures Verify minimum pressures when other household gas appliances are operating Install regulator ...

Страница 42: ...ellifire Ignition System Wiring This appliance requires a 110 120 VAC supply to the ap pliance junction box for operation A wiring diagram is shown in Figure 12 1 WARNING Risk of Shock or Explosion DO NOT wire IPI controlled appliance junction box to a switched circuit Incorrect wiring will override IPI safety lockout This appliance is equipped with an Intellifire control valve which operates on a...

Страница 43: ...G W R REAR VIEW FRONT VIEW CONNECTION AUX GREEN PIGTAIL GROUND RED RED GREEN ORANGE VALVE IPI MALE FEMALE RED RED FEMALE MALE BLACK RED SWITCH AND WIRE ASSEMBLY SUPPLIED WITH WSK MLT TEMPERATURE SENSOR BLUE NOTICE DO NOT wire 110 120 VAC to wall switch Figure 12 2 Junction Box Detail F Junction Box Installation Remove the screw attaching the junction box to the outer shell rotate the junction box ...

Страница 44: ... appliance after installation but before use please replace corrugated splatterguard on unit per directions noted below STEP 1 For Cerona 36 center left to right over glass and fold top center section under top heat shield as in figure 1 For Cerona 42 center left to right over glass and fold top three center sections under top heat shield Figure 13 1 STEP 2 On the Cerona 36 model place outside tab...

Страница 45: ...3 6 Clearances to Mantel Legs or Wall Projections Acceptable on both sides of opening NON COMBUSTIBLE FACING MATERIAL COMBUSTIBLE FACING MATERIAL 1 in TYPICAL D MINIMUM FROM TOP OF ARCH OPENING TO FIRST MANTEL PROJECTION E MINIMUM FROM TOP OF ARCH OPENING TO CEILING FIREPLACE HEADER 1 2 3 4 5 6 7 8 9 10 11 12 TOP OF ARCH OPENING CEILING A B C MAXIMUM A B C D E Cerona 36 in 32 1 4 16 3 4 16 11 49 m...

Страница 46: ...le non combustible definitions WARNING Figure 13 8 A B C Cerona 36 in 49 16 3 4 43 5 8 mm 1245 425 1108 Cerona 42 in 45 1 4 16 3 4 50 5 8 mm 1149 425 1286 Note If using the Apollo Mantel System the appliance must be raised 1 1 4 in from floor A B 1 in 25 C CEILING COMBUSTIBLE SHEATHING NON COMBUSTIBLE FACING MATERIAL IN SHADED AREAS FIREPLACE ARCH OPENING CLEARANCE TO CEILING MINIMUM BOTTOM OF FIR...

Страница 47: ...LLATION Note Please note that there are four holes or dots on the template to assist in positioning the template These holes or dots should line up with the door mounting holes on the unit to ensure proper placement of the door after finishing materials are installed A B Cerona 36 in 43 5 8 50 3 16 mm 1108 1275 Cerona 42 in 50 5 8 54 3 8 mm 1286 1381 F D C B A R I ØH E G A B C D E Cerona 36 in 34 ...

Страница 48: ...ON COMBUSTIBLE HEARTH EXTENSION BOTTOM OF FIREPLACE BOTTOM OF FIREPLACE SURFACE MAY BE COMBUSTIBLE COMBUSTIBLES UP TO 1 INCH THICK ALLOWED UNDER THE OPENING 6 INCHES MINIMUM 1 INCH MAX TO ALLOW FOR DOOR CLEARANCE Figure 13 11 Position of Board and Template NON COMBUSTIBLE BOARD FACING TEMPLATE Figure 13 14 Fireplace Sitting on Combustible Surface Figure 13 12 Fireplace Raised a Minimum of 6 Inches...

Страница 49: ...procedure will likely cause lighting and sooting problems Place Mystic Embers on areas of base refractory away from port holes Use this material to give the appliance a realistic ash bed Save the remaining ember materials for use during appliance servicing The embers provided should be enough for 3 to 5 applications Figure 14 2 Placement of Embers 14 Appliance Setup EMBER PLACEMENT C Inspect Fireb...

Страница 50: ...he right side of the pilot bracket B Move the right end of log 1 forward until it hits the stick on the burner A The closer the log is to the burner the more glow you will get Don t place the log too close to the burner or sooting may occur STEP 2 Log 2 srv2106 703 Fit log 2 on the top branch of log 1 A Rest the formed groove of the lower part of the log on the grate It may be necessary to tilt Lo...

Страница 51: ... should sit flush to burner with no gaps between log and burner 4 5 Figure 6 Figure 7 Figure 8 STEP 5 Log 5 srv2106 702 Place the right portion of log 5 on the formed area of log 1 Place the left side on the grate Set the notch of the log on the grate 6 STEP 6 Log 6 srv2106 706 Rest bottom notch of log 6 on the grate tine and the top part on formed section of log 5 A A ...

Страница 52: ...g Logs are fragile STEP 1 Log 1 srv2107 701 Place log 1 over the back side of the burner plate and slide forward until log hits the grate Log cut out should fit over pilot bracket See Figure 2 STEP 2 Log 2 srv2107 702 Fit log 2 on the right side of the grate The log is formed so it will sit around the right grate bar Rest the top of the log on the flat section of log 1 See Figure 3 1 2 Figure 1 Fi...

Страница 53: ...ace the left formed end of log 4 on the burner detail located under log 3 and the notch on the right end of log 4 on the front grate bar Log 3 may need to be adjusted for proper placement See Figure 5 STEP 5 Log 5 srv2107 705 Place log 5 on the left side between the grate tine and firebox Note This log will be used to support log 6 See Figure 6 4 5 Figure 5 Figure 6 Figure 4 3 TAB NOTCH FITS OVER ...

Страница 54: ... grate tine Log should rest on the flat of log 5 and the flat on log 3 You may need to reposition log 5 to get log 6 to sit in the flats See Figure 7 Figure 7 6 H Fixed Glass Assembly WARNING Risk of Asphyxiation Handle fixed glass assembly with care Inspect the gasket to ensure it is undamaged and inspect the glass for cracks chips or scratches DO NOT strike slam or scratch glass DO NOT operate f...

Страница 55: ...ighten the wing nut NOTICE If sooting occurs provide more air by opening the air shutter Figure 14 3 BOTTOM OF FIREPLACE WITH BOTTOM TRAY REMOVED FIREBOX SUPPORT BASE TEMP SENSOR WING NUT Shutter Settings Burner NG LP Cerona 36 Full Open Full Open Cerona 42 Full Open Full Open K Install Mesh This model requires a door or decorative front Mesh is included with all available decorative fronts L Inst...

Страница 56: ...ot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed incorrectly Verify that transformer is installed and plugged into module Check voltage of transformer under load at spade connection on module with ON OFF switch in ON position Acceptable readings of a good transfor...

Страница 57: ...lot orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod C Module is not grounded Verify module is securely grounded to metal chassis of ap pliance Verify that wire harness is firmly connected to the module D Damaged pilot assembly or contami nated flame sensing r...

Страница 58: ... I J K P L M N O Q R Inches Millimeter Inches Millimeter A 7 178 J 2 1 4 56 B 2 1 8 54 K 5 1 8 130 C 43 1092 L 60 1 2 1537 D 23 1 2 595 M 41 1 8 1046 E 30 1 4 767 N 21 3 4 551 F 33 7 8 860 O 28 1 2 724 G 6 5 8 169 P 14 1 4 362 H 34 1 2 877 Q 12 1 2 316 I 49 7 8 1268 R 8 204 Model Cerona 36 Model Cerona 42 Inches Millimeter Inches Millimeter A 9 1 4 235 J 2 1 4 59 B 2 1 4 56 K 5 3 8 137 C 47 1 8 11...

Страница 59: ...356 mm 1 in 25 mm 8 in 203 mm 6 in 152 mm 10 in 254 mm 1 1 2 in 38 mm 5 in 127 mm 12 in 305 mm UP DVP HVS Vent Support DVP WS Wall Shield Firestop DVP FS Ceiling Firestop DVP45 45º Elbow DVP Pipe see chart Effective Height Length 4 7 8 in 276 mm 13 mm Finished Height 19 3 4 in 502 mm UNIV AS2 Attic Insulation Shield Tab 1 in 25 4 mm 20 3 4 in 527 mm Pipe Effective Length Inches Millimeters DVP4 4 ...

Страница 60: ...1 2 in 38 mm The heat shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is greater than 7 1 4 in 184 mm a DVP HSM B will be required Heat Shield B Vent Components Diagrams continued Figure 16 3 DVP vent components Term Cap Minimum Effective Length Maximum Effec...

Страница 61: ...k Extension 13 3 4 in 349 mm 5 in 127 mm 13 3 4 in 349 mm Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 356 mm COOL ADDM Cap Shield 11 5 8 in 295 mm 5 3 4 in 146 mm 7 1 8 in 181 mm 12 1 8 in 308 mm DVP BEK2 DVP HPC Cap Brick Extension 13 7 8 in 352 mm 5 in 127 mm 11 7 8 in 302 mm DVP TRAPFL Flashing 26 in 660 mm DVP HSM B Extended Heat Shield B Vent Components Diagrams continued Fig...

Страница 62: ... mm 12 in 305 mm 12 1 8 in 314 mm 7 1 8 in 181 mm 8 3 4 in 222 mm 1 5 8 in 41 mm 16 7 8 in 429 mm DVP HPC High Performance Cap 1 in 25 mm 14 in 356 mm 3 8 in 10 mm 1 in 25 mm 7 1 4 in 184 mm 7 3 4 to 10 3 8 in 197 to 264 mm DVP FBHT FireBrickTermination Cap Ø11 1 2 in 292 mm 12 1 2 in 318 mm 16 in 406 mm 9 in 229 mm 2 3 4 in 70 mm 12 1 4 in 311 mm B Vent Components Diagrams continued Figure 16 5 V...

Страница 63: ... appliance and are ordered separately from PVI SLP Contact your dealer to order 12 1 2 IN 318 mm 20 3 4 IN 527 mm 13 5 8 IN 346 mm EFFECTIVE LENGTH 32 IN 813 mm MIN 35 IN 889 mm MAX Note Use only approved termination caps with the PVI SLP See instructions included with PVI SLP kit SLP LPC SLP Low Profile Cap 16 IN 406 mm 15 IN 381 mm 16 11 16 IN 424 mm 9 3 16 IN 233 mm 4 1 2 IN 114 mm 16 11 16 IN ...

Страница 64: ...MENTS PART NUMBER Log Set Assembly LogS CERoNA36 Y 1 Log 1 SRV2106 701 2 Log 2 SRV2106 703 3 Log 3 SRV2106 705 4 Log 4 SRV2106 704 5 Log 5 SRV2106 702 6 Log 6 SRV2106 706 7 Top Header Heat Shield 2106 144 8 Bottom Header Heat Shield 2106 145 9 Non Combustible Board Assembly 2106 030 10 Burner Ng LP 2106 003 Y 11 grate Assembly 2106 006 12 glass door Assembly gLA CERoNA36 Y 13 Fan Kit gFK 160A 14 J...

Страница 65: ...COMMENTS PART NUMBER Log Set Assembly LogS CERoNA42 Y 1 Log 1 SRV2107 701 2 Log 2 SRV2107 702 3 Log 3 SRV2107 703 4 Log 4 SRV2107 704 5 Log 5 SRV2107 705 6 Log 6 SRV2107 706 7 Top Header Heat Shield 2107 144 8 Bottom Header Heat Shield 2107 145 9 Non Combustible Board 2107 030 10 Burner Ng LP 2107 003 Y 11 grate Assembly 2106 006 12 glass door Assembly gLA CERoNA42 Y 13 Fan Kit gFK 160A 14 Junctio...

Страница 66: ...mbly 302 320A Y 15 6 Module wire Assembly 593 590A Y 15 7 Battery Pack 593 594A Y 15 8 Module 593 592 Y 15 9 Valve Ng 750 500 Y Valve LP 750 501 Y 15 10 Valve Bracket 2106 107 15 11 High Temp Limit Switch Pre June 2009 must order both switch Wire and shutter Bracket asssembly 2106 005 and 107 559A Y 2106 010 NG or 2106 071 LP Y Post June 2009 2106 005 Y 15 12 Flexible gas Connector 530 302A Y 15 1...

Страница 67: ...BER Fiber Patch Kit PATCHKIT FB Touch up Paint Fiber CERoNA PAINT Fiberglass Rope 060 455 glass Latch Assembly Pkg of 2 386 122A 2 Y Heat Shield J Box 2106 130 Mineral wool 050 721 on off Rocker Switch 060 521A Y Screw Bag of 32 ea 2062 110 23 Y Touch Up Paint Metal TUP gBK 12 Vermiculite Embers MYSTIC EMBERS Vertical Restrictor 2106 141 wires 2 in Male to Male 2012 206 Y wire wall Switch 2095 550...

Страница 68: ..._____________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this m...

Отзывы: