B. Mantel and Wall Projections
WARNING! Risk of Fire!
Comply with all minimum clear-
ances as specified. Framing closer than the minimums list
-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.)
Figure 10.3 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible or Painted Surfaces
127
254
279
305
64
330
356
381
406
432
457
483
813
TO CEILING
229
254
279
305
203
178
152
102
76
635
457
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 in. (851 mm)
127
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note:
All
measurements
in millimeters.
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62
87
113
138
164
189
B
Inches
1
2
3
4
5
∞
Millimeters
25
51
76
102
127
∞
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
Mantels - Combustible or Painted Surfaces
Mantel Legs or Wall Projections
Figure 10.5 Clearances to Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Figure 10.4 Minimum Vertical and Maximum Horizontal
Dimensions - Non-Combustible
Mantels - Non-Combustible
381
406
432
457
483
813
TO CEILING
229
254
279
305
203
178
152
635
457
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 in. (851 mm)
356
Note:
All
measurements
in millimeters.
Note:
Measurement is taken from top of the opening,
NOT the top of the fireplace.
Combustible or Painted Surfaces
Non-Combustible
If
A
minimum is ____, then
B
maximum is_____.
A
Inches
0 thru 5-7/16
6-7/16
Millimeters
0-138
164
B
Inches
6
∞
Millimeters
152
∞