33
Heat & Glo • 6X-AU Installation Manual • 2508-980 Rev. C
• 3/18
Figure 6.11
Attach the first vent section (it will snap into
place). Slide the insulation gasket onto the vent section,
up against the appliance and over the tabs.
Figure 6.12 Heat-Zone
®
-240V
Knockout Locations
B. Installing Optional Heat-Zone
®
-240V
•
Remove the knockout from the fireplace and discard it
See Figure 6.12.
• Center the duct collar around the exposed hole and
attach it to the fireplace with 3 screws. Note: Do this
BEFORE final positioning of fireplace.
• Determine the location for the air register/fan housing
assembly.
Reference the appropriate instructions included with the
kit for the remaining installation steps.
HEAT-ZONE
®
-240V KNOCKOUT LOCATIONS
(LEFT AND RIGHT SIDES)