Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. K • 12/07
13
Figure 5.3
Figure 5.4
D. Vent Diagrams
WARNING
1. Top Vent - Horizontal Termination
One Elbow
Two Elbows
NOTE:
For corner installations: A 6 inch
(152mm) section of straight pipe may need
to be attached to the appliance before a
90
o
elbow, to allow the vent pipe to clear
the top standoffs.
NOTE:
For corner installations: A
6 inch (152mm) section of straight
pipe may need to be attached to
the appliance before a 90
o
elbow, to
allow the vent pipe to clear the top
standoffs.
V
1
Minimum
H
1
Maximum
Elbow only
2 ft
610 mm
1 ft.
305 mm
3 ft.
914 mm
2 ft.
610 mm
6 ft.
1.8 m
3 ft.
914 mm
11 ft.
3.4 m
4 ft.
1.2 m
20 ft.
6.1 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 20 ft. (6.1 m) Maximum
V
1
Minimum
H
1
+ H
2
Maximum
Elbow only
1 ft.
305 mm
6 in.
152 mm
2 ft.
610 mm
1 ft.
305 mm
2 ft.
610 mm
2 ft.
610 mm
4 ft.
1.2 m
3 ft.
914 mm
9 ft.
2.7 m
4 ft.
1.2 m
18 ft.
5.5 m
5 ft.
1.5 m
20 ft.
6.1 m
V
1
+ H
1
+ H
2
= 40 ft. (12.2 m) Maximum
H
1
+ H
2
= 20 ft. (6.1 m) Maximum
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles
between ceiling fi restops.
• ALWAYS maintain specified clearances
around venting and fi restop systems.
• Install wall shield and ceiling fi restops as
specifi ed.
Failure to keep insulation or other material
away from vent pipe may cause fi re.
NOTE: The 6000 series fi replaces can adapt
to SL series vent pipe, if desired.
When venting off the top of the unit, use a DVP-2SL adapter
and a minimum 48 inch vertical section of SL series vent
pipe.
After
the 48 inch vertical section, the venting table rules
must be followed. The fi rst 48 inch vertical section is NOT
counted as part of the
vertical
components in the table. It is
still counted as part of the overall maximum run. All venting
table rules for the vent run must still be followed.
Example:
DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal
SL pipe 7 ft. min. vertical = 11 ft. max. horizontal
Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-
SS termination caps on top vented fi replaces, a
6 inch minimum vertical vent section is required
before installing fi rst elbow.
WARNING