Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. W • 8/14
18
Figure 3.4 Valve Assembly Removal
NOTCH LOCATION
NG LP
6000CL
6000CLX
8000CL
8000CLX
Figure 3.5 Burner Identi
fi
cation
D. Burner Identi
fi
cation/Veri
fi
cation
The burner may be accessed for identi
fi
cation and veri
fi
cation purposes. This task should be performed by a quali
fi
ed ser-
vice technician. The base refractory, valve plate and grate do not need to be removed to access the burner assembly. The
logs and
fi
ber burner top need to be removed to access the burner. Disconnect the pilot from the burner before removal.
See Figure 3.5 for burner identi
fi
cation chart. Notch patterns are located on bottom side of burner.