25
Heat & Glo • 6000BEC-IPI, 6000BEC-IPILP • 2187-900 Rev. K • 4/15
EXHAUST
SHIELD
FLUE
RESTRICTOR
Top Vent - Vertical Termination
No Elbow
Figure 7.6
Note:
If installing a vertical vent/
termination off the top of the appli-
ance, the
fl
ue restrictor should be
used. See Figure 7.9.
V
1
V
1
= 40 ft. Max. (12.4 m)
V
1
= 3 ft. Min. (914 mm)
Flue Restrictor Instructions
Figure 7.7
1. Remove exhaust shield using a 1/4 inch nut driver by
removing the screws securing it in place. See Figure
7.7.
2. Orientate and align the two pieces of the
fl
ue restrictor
as shown in Figure 7.9.
3. Match the amount of vertical you have in the system
with the chart to
fi
nd the appropriate position to set the
fl
ue restrictor. See Figure 7.8 and 7.9.
4. Center the two
fl
ue restrictor pieces on the vent at the
setting selected in step 3 and secure in place by using
two self-tapping screws. See Figure 7.7.
5. Reinstall the exhaust shield.
Vertical
TOP VENT
REAR VENT
NG
LP
NG
LP
4 ft.
1-1
No
Restrictor
No
Restrictor
No
Restrictor
8 ft.
2-2
1-2
1-1
No
Restrictor
15 ft.
3-3
3-2
2-2
1-2
20 ft.
3-4
3-3
3-3
2-3
25 ft.
3-4
3-3
3-3
2-3
30 ft.
4-4
3-4
3-4
3-3
35 ft.
4-4
3-4
3-4
3-3
40 ft.
5-4
4-4
4-4
3-4
Figure 7.8