background image

DHW Energy Saver Installation and Configuration Manual  

11

HT# 059106-00C

11

DHW Energy Saver

Boiler

Pump

6

7

8

9

COM

3

4

5

B      A  GND

16VAC

1

2

~      ~

Typical Wiring for Platinum

Serial Panel TS485 Plug

HWR

Platinum

MADE IN U S A 

PREV 

(DEL)

SAFETY

GROUND

MUST BE

CONNECTED

OUT

TEMP

DHW

CAL

AUX

TEMP 0

AUX

TEMP 1

MENU FUNCTIONS

SELECT enters menus or accepts changes

ADJUST selects menu items or changes settings

BACK returns to previous menu

DAY  selects next day

PREV /NEXT  steps through output status

PUMP

LI

N

E

N

E

U

TR

A

L

DAY

HELP

NEXT

PRESS TO

SELECT

BACK

MON  12/28/04  10:43Am

ADJUST

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

AUX

TEMP 2

DO NOT APPLY ANY VOLTAGE

TO SENSOR TERMINALS

A13

A14

A15

A16

A17

A18

NETWORK

PROVE

SHUTDOWN

SYSTEM

TEMP

CLOSE

OPEN

(BYPASS)

ALL SENSORS MUST BE

GOLD SERIES SENSORS

INPUTS

ROUTE SENSOR AND AUXILIARY WIRES

THROUGH THIS KNOCKOUT ONLY

BURNER

MOTORIZED

VALVE

CLOSE

OPEN

OPTION

1

OPTION

2

T

T

T

TGT= 126

o

F

Cut= 55

o

F  Day

OD= 31

o

F  SYS= 125

o

F

AUTO

AUX

CLOCK

PUMP

BURNER

MOTORIZED

VALVE

CLOSE

OPEN

OPTION

1

OPTION

2

AUX

CLOCK

T

T

C  O  R  P  O  R  A  T  I  O  N

R

2

3

4

5

5A

6

7

8

9

11

12

13

14

15

16

17

OUTPUT RATINGS:

120VAC, 6A RESISTIVE

1A PILOT DUTY

15A TOTAL

FOR ALL CIRCUITS

INPUT RATINGS:

115VAC 60Hz

30VA MAX

USE COPPER WIRE,

CLASS 1 WIRE ONLY

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

99RA

PREV 

(DEL)

OUT

TEMP

DHW

CAL

AUX

TEMP 0

AUX

TEMP 1

PUMP

DAY

HELP

NEXT

PRESS TO

SELECT

BACK

A9

A10

A11

A12

AUX

TEMP 2

A13

A14

A15

A16

A17

A18

BURNER

MOTORIZED

VALVE

CLOSE

OPEN

OPTION

1

OPTION

2

T

T

T

TGT= 126

o

F

Cut= 55

o

F  Day

OD= 31

o

F  SYS= 125

o

F

AUX

CLOCK

PUMP

BURNER

MOTORIZED

VALVE

CLOSE

OPEN

OPTION

1

OPTION

2

AUX

CLOCK

T

5

5A

6

7

8

9

11

12

13

14

15

16

17

Supply Sensor

Return Sensor

Sensor

Shield

Recirculating

Pump

Boiler

Boiler Heat

Exchanger

Return

Sensor

Supply

Sensor

Tempering

Valve

Cold

Control Valve
Check Valve

Sensor Shield (Connect to O)

Piping/Wiring to Boiler and a Tempering Valve

Suggested Settings:

Supply Set Point 180°F

Peak Differential 10°F

Light Differential 20°F (Steel Boiler)

Light Differential 40°F (Cast Iron Boiler)

Return Set Point 120°F

Peak Differential 5°F

Light Differential 10°F

Heat-Timer is aware that each installation is unique  Thus, is not responsible for any installation related to any electrical or plumbing 

diagram generated by Heat-Timer  The provided illustrations are to demonstrate Heat-Timer’s control operating concept only 

Control Valve
Check Valve
Sensor Shield (Connect to O)

Содержание DHW Energy Saver

Страница 1: ...y an operating control it should never be used as a primary limit or safety control All equipment must have its own certified limit and safety controls required by local codes The installer must verif...

Страница 2: ...re Sensor 5 Return Temperature Sensor 5 PLATINUM CONTROL MENU SETTINGS 6 ICMS WEB MENU SETTINGS 6 Using the Supply or Return Sensor 7 Supply or Return Set Point 7 Supply or Return Peak and Light Diffe...

Страница 3: ...the supply temperature drops below the Supply Set Point and differential the Control will energize the boiler output The boiler output will remain energized until the supply temperature reaches the Su...

Страница 4: ...ol Connect the transformer outputs to the DHW Energy Saver s left most terminals Power polarity is not observed WARNING DO NOT share the DHW Energy Saver transformer with other devices This may cause...

Страница 5: ...anual operation of the pump DHW Energy Saver Boiler Pump 6 7 8 9 COM 3 4 5 A GND B 16VAC 1 2 DHW Pump L N Bypass Switch Optional Temperature Sensor Wiring Only use a Standard Brass Tube sensor provide...

Страница 6: ...HW SETTINGS Supply Settings Return Settings Demand Schedule Copy Schedule DHW Settings DHW SUPPLY SETTINGS Use Sensor Yes Setpoint 140 F Peak Diff 20 F Light Diff 40 F DHW RETURN SETTINGS Use Sensor Y...

Страница 7: ...relay will de energize The circulating pump relay will energize whenever the return temperature drops below this set point less the differential See next setting DHW SUPPLY SETPOINT 140 F DHW RETURN S...

Страница 8: ...on the ICMS web site Select Alarm Delivery Setup and then Add Delivery for the Sensor Fault WARNING The boiler water heater must have its operating and limit controls installed and wired in a way so...

Страница 9: ...X CLOCK T T C O R P O R A T I O N R 2 3 4 5 5A 6 7 8 9 11 12 13 14 15 16 17 OUTPUT RATINGS 120VAC 6A RESISTIVE 1A PILOT DUTY 15A TOTAL FOR ALL CIRCUITS INPUT RATINGS 115VAC 60Hz 30VA MAX USE COPPER WI...

Страница 10: ...ESS TO SELECT BACK MON 12 28 04 10 43Am ADJUST A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 AUX TEMP 2 DO NOT APPLY ANY VOLTAGE TO SENSOR TERMINALS A13 A14 A15 A16 A17 A18 NETWORK PROVE SHUTDOWN SYSTEM TEMP...

Страница 11: ...OUTPUT RATINGS 120VAC 6A RESISTIVE 1A PILOT DUTY 15A TOTAL FOR ALL CIRCUITS INPUT RATINGS 115VAC 60Hz 30VA MAX USE COPPER WIRE CLASS 1 WIRE ONLY ENCLOSED ENERGY MANAGEMENT EQUIPMENT 99RA PREV DEL OUT...

Страница 12: ...ltage Input 16 VAC transformer provided minimum 10VA Output Relays 2 N O SPST Each a maximum HP pump or 6 Amp resistive load at 120 VAC 60 Hz Outputs DHW boiler water heater and DHW pump Communication...