These units 

MUST 

use one of the vent systems

described in the Installing the Fireplace section of

the 

Installers Guide

NO OTHER 

vent systems or

components 

MAY BE USED

.

This gas fireplace and vent assembly 

MUST 

be

vented directly to the outside and 

MUST NEVER 

be

attached to a chimney serving a separate solid fuel

burning appliance. Each gas appliance 

MUST USE

a separate vent system. Common vent systems are

PROHIBITED

.

INSPECT 

the external vent cap on a regular basis to

make sure that no debris is interfering with the air

flow.

The glass door assembly 

MUST 

be in place and

sealed, and the trim door assembly 

MUST 

be in

place on the fireplace before the unit can be placed

into safe operation.

DO NOT OPERATE 

this appliance with the glass

door removed, cracked, or broken. Replacement of

the glass door should be performed by a licensed

or qualified service person. 

DO NOT 

strike or slam

the glass door.

The glass door assembly 

SHALL ONLY 

be

replaced as a complete unit, as supplied by the gas

fireplace manufacturer. 

NO SUBSTITUTE 

material

may be used.

DO NOT USE 

abrasive cleaners on the glass door

assembly. 

DO NOT ATTEMPT 

to clean the glass

door when it is hot.

Turn off the gas before servicing this appliance. It is

recommended  that  a  qualified  service  technician

perform an appliance check-up at the beginning of

each  heating  season.

Any safety screen or guard removed for servicing

must be replaced before operating this appliance.

READ 

and 

UNDERSTAND 

all instructions carefully

before starting the installation. 

FAILURE TO

FOLLOW 

these installation instructions may result

in a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, 

READ 

the

Using Your Fireplace section of the 

Owners Guide

.

DO NOT USE 

this appliance if any part has been

under water. Immediately 

CALL 

a qualified service

technician to inspect the unit and to replace any part

of the control system and any gas control which has

been under water.

THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be 

PERFORMED 

by a

qualified service person. The appliance and venting

system should be 

INSPECTED 

before initial use

and at least annually by a professional service

person. More frequent cleaning may be required

due to excessive lint from carpeting, bedding

material, etc. It is 

IMPERATIVE 

that the unit’s

control compartment, burners, and circulating air

passageways 

BE KEPT CLEAN 

to provide for

adequate combustion and ventilation air.

Always 

KEEP 

the appliance clear and free from

combustible  materials,  gasoline,  and  other

flammable  vapors  and  liquids.

NEVER OBSTRUCT 

the flow of combustion and

ventilation air. Keep the front of the appliance

CLEAR 

of all obstacles and materials for servicing

and  proper  operations.

Due to the high temperature, the appliance should

be 

LOCATED 

out of traffic areas and away from

furniture  and  draperies.  Clothing  or  flammable

material 

SHOULD NOT BE PLACED 

on or near the

appliance.

Children and adults should be 

ALERTED 

to the

hazards of high surface temperature and should

STAY AWAY 

to avoid burns or clothing ignition.

Young children should be 

CAREFULLY SUPERVISED

when they are in the same room as the appliance.

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

SAFETY AND WARNING INFORMATION

!

Содержание SL-350TV

Страница 1: ...derwriters Laboratories Listed 541 985C 4 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Страница 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Страница 3: ...m 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control System...

Страница 4: ...urrent edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas and...

Страница 5: ...ailure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following...

Страница 6: ...837mm 30 1 2 775mm 2 1 4 57mm 5 3 8 138mm GAS LINE ACCESS 11 3 8 288mm 1 2 13mm 4 101mm B VENT 8 1 2 216mm 16 1 4 414mm 15 3 4 400mm 22 5 8 575mm ELECTRICAL ACCESS TOP STANDOFFS HOOD VENT COLLARS ELEC...

Страница 7: ...l is 1 2 inch 13mm A 34 B 31 C 16 1 4 Figure 3 Framing Dimensions The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construct...

Страница 8: ...e is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mechanically or passively balanced t...

Страница 9: ...inside the unit to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system...

Страница 10: ...Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non co...

Страница 11: ...line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 8 Gas Pressure Requirements Pressure require...

Страница 12: ...ts require that 110 120 VAC be wired to the factory installed junction box before the fireplace is per manently installed Figure 10 Standing Pilot Ignition Wiring Diagram NOTE THIS UNIT IS NOT APPROVE...

Страница 13: ...b into the pilot hole on the outer wrap Optional Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 11 Direct Spark Ignition DSI Wiring Dia...

Страница 14: ...ce but MUST NEVER overlap onto the front face The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F 149 C minimum sealant WARNING WHEN FINISHING THE FIRE...

Страница 15: ...run for 8 hours on the initial start up This will help to cure the chemicals used in the paint and logs Subsequent lightings of the fireplace will not require this purging of air from the gas supply...

Страница 16: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...

Отзывы: