Figure 15.   Placement of the Ember Material

Step 12.  Before Lighting  the Fireplace

Before

 lighting the fireplace, be sure to do the following:

Remove all paperwork from underneath the fireplace.
Review safety warnings and cautions

• Read the 

Safety and Warning Information

 section at

the beginning of this 

Installers Guide

.

Double-check for gas leaks

• Before lighting the fireplace, double-check the unit for

possible gas leaks.

Double-check vent terminations and front grilles for

obstructions.

• Before lighting the fireplace, double-check the unit for

possible obstructions that could be blocking the vent ter-

minations or the front grilles.

!

!

Double-check  that  grate  shipping  support  was  re-

moved (see page 16).

• Make sure that the grate is resting directly on the refrac-

tory.

Double-check for faulty components

• Any component that is found to be faulty 

MUST BE

 re-

placed with an approved component. Tampering with the

fireplace components is 

DANGEROUS

 and voids all war-

ranties.

A small amount of air will be in the gas supply lines. When

first lighting the fireplace, it will take a few minutes for the

lines to purge themselves of this air. Once the purging is

complete, the fireplace will light and will operate normally.

NOTE:

 The fireplace should be run for 8 hours on the initial

start-up. This will help to cure the chemicals used in the

paint and logs.
Subsequent lightings of the fireplace will not require this

purging of air from the gas supply lines,

 unless

 

the gas

valve has been turned to the OFF position

, in which

case the air would have to be purged.

Step 13.   Lighting the Fireplace

You’ve reviewed all safety warnings, you’ve checked the

fireplace  for  gas  leaks,  you  know  the  vent  system  is

unobstructed, and you’ve checked for faulty components.

Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’S

MANUAL FOR ALL CAUTIONS, SAFETY,  AND

WARNING INFORMATION PERTAINING TO THE

LIGHTING AND OPERATION OF THE FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH

THE APPLIANCE FOR FUTURE REFERENCE.

EMBER MATERIALS

Placing the Ember Material

Ember material is shipped with this gas fireplace. The bag

labeled Glowing Ember (050-721) is standard glowing ember

material. To place the ember material:
• Remove the mesh or open the glass doors (if equipped).
• Place dime size pieces of ember material about 1/2 inch

apart near port holes in burner top. Do NOT press em-

bers into burner ports. Cover the top of the burner with a

single layer of ember material. For best performance do

NOT place embers on the ports at the rear of the burner

(see Figure 15).

• Save the remaining ember materials for use during fire-

place servicing. The bag of embers provided is sufficient

for 3 to 5 applications.

• Replace the mesh or close the glass doors (if equipped)

on the unit.

Содержание SL-350TV

Страница 1: ...derwriters Laboratories Listed 541 985C 4 00 READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE Please contact your H...

Страница 2: ...he installation FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty Prior to the first firing of the fireplace READ the Using Your Firepla...

Страница 3: ...m 11 A Vent System Approvals 11 B System Components 11 C Bedroom Installation in Canada 12 D Vent Termination 12 Step 5 Positioning Leveling and Securing the Fireplace 12 Step 6 The Gas Control System...

Страница 4: ...urrent edition The Uniform Mechanical Code current edition and local Building Officials for the options allowed in obtaining an effective bedroom volume of unconfined space This model natural gas and...

Страница 5: ...ailure to follow these instructions will void the owner s warranty and may present a fire hazard The Heat N Glo Warranty will be voided by and Heat N Glo disclaims any responsibility for the following...

Страница 6: ...837mm 30 1 2 775mm 2 1 4 57mm 5 3 8 138mm GAS LINE ACCESS 11 3 8 288mm 1 2 13mm 4 101mm B VENT 8 1 2 216mm 16 1 4 414mm 15 3 4 400mm 22 5 8 575mm ELECTRICAL ACCESS TOP STANDOFFS HOOD VENT COLLARS ELEC...

Страница 7: ...l is 1 2 inch 13mm A 34 B 31 C 16 1 4 Figure 3 Framing Dimensions The distance from the unit to combustible construction is to be measured from the unit outer wrap surface to the combustible construct...

Страница 8: ...e is located It is recommended that all natural venting non air tight gas fireplaces have outside air connected to them It is also recommended that the building be mechanically or passively balanced t...

Страница 9: ...inside the unit to check that the vent pipe is attached NOTE It is always better to first attach a straight section of vent to the unit before attaching an elbow Avoid using elbows in the vent system...

Страница 10: ...Fireplace To properly position level and secure the fireplace Place the fireplace into position see Figure 7 Level the fireplace from side to side and from front to back Shim the fireplace with non co...

Страница 11: ...line through the gas line hole and connect it to the shut off valve When attaching the pipe support the control so that the lines are not bent or torn Step 8 Gas Pressure Requirements Pressure require...

Страница 12: ...ts require that 110 120 VAC be wired to the factory installed junction box before the fireplace is per manently installed Figure 10 Standing Pilot Ignition Wiring Diagram NOTE THIS UNIT IS NOT APPROVE...

Страница 13: ...b into the pilot hole on the outer wrap Optional Accessories Optional remote control kits require that 110 120 VAC be wired to the fireplace junction box Figure 11 Direct Spark Ignition DSI Wiring Dia...

Страница 14: ...ce but MUST NEVER overlap onto the front face The joints between the finished wall and the fireplace top and sides can only be sealed with a 300 F 149 C minimum sealant WARNING WHEN FINISHING THE FIRE...

Страница 15: ...run for 8 hours on the initial start up This will help to cure the chemicals used in the paint and logs Subsequent lightings of the fireplace will not require this purging of air from the gas supply...

Страница 16: ...annually By Qualified service technician Task Brush or vacuum the control compartment fireplace logs and burner areas surrounding the logs Checking Flame Patterns Flame Height Frequency Periodically B...