12
B. Installing Vent Components
1. Attach the First Vent Component to the Starting Collars
To attach the first vent component (3 foot straight pipe
minimum) to the starting collars of the fireplace:
Apply a 3/8 inch (9.5 mm) bead of stove cement
around the inner pipe fireplace starting collar.
Make sure that the fireplace rope gasket supplied
with the fireplace seals between the first 8-5/8 inch
(219mm) vent component and the fireplace top.
Lock the vent components into place by sliding the
concentric pipe sections with four (4) equally
spaced interior beads into the fireplace collar or
previously installed component end with four (4)
equally spaced indented sections.
When the internal beads of each outer pipe line up,
rotate the pipe section clockwise about one-quarter
(1/4) turn. The vent pipe is now locked together.
1. Apply the stove
cement.
2. Line up the internal
beads and rotate the
pipe sections clock-
wise until locked.
3. Lock the vent compo-
nents into place.
4. Check the seal on the
rope gasket.
Figure 10. Attaching the First Vent Component to
the Starting Collars
WARNING: A 3/8 INCH (9.5 MM) BEAD
OF STOVE CEMENT MUST BE PLACED
AROUND THE INNER PIPE FIREPLACE
STARTING COLLAR BEFORE ATTACHING
THE FIRST VENT COMPONENT.
FAILURE TO SEAL THIS JOINT MAY
CAUSE THE FIREPLACE TO OPERATE
IMPROPERLY. SEE THE DIAGRAM .
WARNING: ENSURE THAT THE
FIBERGLASS ROPE GASKET SUPPLIED
WITH THE FIREPLACE SEALS BETWEEN
THE FIRST VENT COMPONENT AND
THE FIREPLACE TOP.
STARTING
COLLAR
STARTING
COLLAR
FIRST
VENT
COMPONENT
FIRST
VENT
COMPONENT
STOVE
SEALANT
BEAD
3/8" (9.5 mm)
STOVE
SEALANT
BEAD
3/8" (9.5 mm)
1 INCH (25.4 mm)